-
Something wrong with this record ?
Repetitive Detection of Aromatic Hydrocarbon Contaminants with Bioluminescent Bioreporters Attached on Tapered Optical Fiber Elements
J. Zajíc, S. Ripp, J. Trögl, G. Kuncová, M. Pospíšilová
Language English Country Switzerland
Document type Journal Article
Grant support
SGS17/110/OHK4/1T/17
České Vysoké Učení Technické v Praze
SGS18/097/OHK4/1T/17
České Vysoké Učení Technické v Praze
CZ.02.1.01/0.0/0.0/17_048/0007435
Ministerstvo Školství, Mládeže a Tělovýchovy
NLK
Directory of Open Access Journals
from 2001
PubMed Central
from 2003
Europe PubMed Central
from 2003
ProQuest Central
from 2001-01-01
Open Access Digital Library
from 2001-01-01
Open Access Digital Library
from 2003-01-01
Health & Medicine (ProQuest)
from 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2001
PubMed
32517218
DOI
10.3390/s20113237
Knihovny.cz E-resources
- MeSH
- Hydrocarbons, Aromatic analysis MeSH
- Biosensing Techniques * MeSH
- Escherichia coli MeSH
- Luminescent Measurements * MeSH
- Optical Fibers MeSH
- Pseudomonas putida MeSH
- Toluene analysis MeSH
- Publication type
- Journal Article MeSH
In this study, we show the repetitive detection of toluene on a tapered optical fiber element (OFE) with an attached layer of Pseudomonas putida TVA8 bioluminescent bioreporters. The bioluminescent cell layer was attached on polished quartz modified with (3-aminopropyl)triethoxysilane (APTES). The repeatability of the preparation of the optical probe and its use was demonstrated with five differently shaped OFEs. The intensity of measured bioluminescence was minimally influenced by the OFE shape, possessing transmittances between 1.41% and 5.00%. OFE probes layered with P. putida TVA8 were used to monitor liquid toluene over a two-week period. It was demonstrated that OFE probes layered with positively induced P. putida TVA8 bioreporters were reliable detectors of toluene. A toluene concentration of 26.5 mg/L was detected after <30 min after immersion of the probe in the toluene solution. Additional experiments also immobilized constitutively bioluminescent cells of E. coli 652T7, on OFEs with polyethyleneimine (PEI). These OFEs were repetitively induced with Lauria-Bertani (LB) nutrient medium. Bioluminescence appeared 15 minutes after immersion of the OFE in LB. A change in pH from 7 to 6 resulted in a decrease in bioluminescence that was not restored following additional nutrient inductions at pH 7. The E. coli 652T7 OFE probe was therefore sensitive to negative influences but could not be repetitively used.
Center for Environmental Biotechnology University of Tennessee Knoxville TN 37996 USA
Department of Cardiology Regional Hospital Liberec 46063 Liberec Czech Republic
Faculty of Biomedical Engineering Czech Technical University Prague 27201 Kladno Czech Republic
Institute of Chemical Process Fundamentals of the ASCR 16502 Prague Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21012493
- 003
- CZ-PrNML
- 005
- 20210507104502.0
- 007
- ta
- 008
- 210420s2020 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s20113237 $2 doi
- 035 __
- $a (PubMed)32517218
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Zajíc, Jakub $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 27201 Kladno, Czech Republic $u Center for Environmental Biotechnology, University of Tennessee, Knoxville, TN 37996, USA $u Department of Cardiology, Regional Hospital Liberec, 46063 Liberec, Czech Republic
- 245 10
- $a Repetitive Detection of Aromatic Hydrocarbon Contaminants with Bioluminescent Bioreporters Attached on Tapered Optical Fiber Elements / $c J. Zajíc, S. Ripp, J. Trögl, G. Kuncová, M. Pospíšilová
- 520 9_
- $a In this study, we show the repetitive detection of toluene on a tapered optical fiber element (OFE) with an attached layer of Pseudomonas putida TVA8 bioluminescent bioreporters. The bioluminescent cell layer was attached on polished quartz modified with (3-aminopropyl)triethoxysilane (APTES). The repeatability of the preparation of the optical probe and its use was demonstrated with five differently shaped OFEs. The intensity of measured bioluminescence was minimally influenced by the OFE shape, possessing transmittances between 1.41% and 5.00%. OFE probes layered with P. putida TVA8 were used to monitor liquid toluene over a two-week period. It was demonstrated that OFE probes layered with positively induced P. putida TVA8 bioreporters were reliable detectors of toluene. A toluene concentration of 26.5 mg/L was detected after <30 min after immersion of the probe in the toluene solution. Additional experiments also immobilized constitutively bioluminescent cells of E. coli 652T7, on OFEs with polyethyleneimine (PEI). These OFEs were repetitively induced with Lauria-Bertani (LB) nutrient medium. Bioluminescence appeared 15 minutes after immersion of the OFE in LB. A change in pH from 7 to 6 resulted in a decrease in bioluminescence that was not restored following additional nutrient inductions at pH 7. The E. coli 652T7 OFE probe was therefore sensitive to negative influences but could not be repetitively used.
- 650 12
- $a biosenzitivní techniky $7 D015374
- 650 _2
- $a Escherichia coli $7 D004926
- 650 _2
- $a aromatické uhlovodíky $x analýza $7 D006841
- 650 12
- $a luminiscenční měření $7 D008163
- 650 _2
- $a optická vlákna $7 D055100
- 650 _2
- $a Pseudomonas putida $7 D016958
- 650 _2
- $a toluen $x analýza $7 D014050
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Ripp, Steven $u Center for Environmental Biotechnology, University of Tennessee, Knoxville, TN 37996, USA
- 700 1_
- $a Trögl, Josef $u Faculty of Environment, Jan Evangelista Purkyně University in Ústí nad Labem, 40096 Ústí nad Labem, Czech Republic
- 700 1_
- $a Kuncová, Gabriela $u Faculty of Environment, Jan Evangelista Purkyně University in Ústí nad Labem, 40096 Ústí nad Labem, Czech Republic $u Institute of Chemical Process Fundamentals of the ASCR, 16502 Prague, Czech Republic
- 700 1_
- $a Pospíšilová, Marie $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 27201 Kladno, Czech Republic
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 20, č. 11 (2020)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32517218 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210420 $b ABA008
- 991 __
- $a 20210507104501 $b ABA008
- 999 __
- $a ok $b bmc $g 1650788 $s 1132872
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 20 $c 11 $e 20200606 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- GRA __
- $a SGS17/110/OHK4/1T/17 $p České Vysoké Učení Technické v Praze
- GRA __
- $a SGS18/097/OHK4/1T/17 $p České Vysoké Učení Technické v Praze
- GRA __
- $a CZ.02.1.01/0.0/0.0/17_048/0007435 $p Ministerstvo Školství, Mládeže a Tělovýchovy
- LZP __
- $a Pubmed-20210420