• Something wrong with this record ?

Repetitive Detection of Aromatic Hydrocarbon Contaminants with Bioluminescent Bioreporters Attached on Tapered Optical Fiber Elements

J. Zajíc, S. Ripp, J. Trögl, G. Kuncová, M. Pospíšilová

. 2020 ; 20 (11) : . [pub] 20200606

Language English Country Switzerland

Document type Journal Article

Grant support
SGS17/110/OHK4/1T/17 České Vysoké Učení Technické v Praze
SGS18/097/OHK4/1T/17 České Vysoké Učení Technické v Praze
CZ.02.1.01/0.0/0.0/17_048/0007435 Ministerstvo Školství, Mládeže a Tělovýchovy

In this study, we show the repetitive detection of toluene on a tapered optical fiber element (OFE) with an attached layer of Pseudomonas putida TVA8 bioluminescent bioreporters. The bioluminescent cell layer was attached on polished quartz modified with (3-aminopropyl)triethoxysilane (APTES). The repeatability of the preparation of the optical probe and its use was demonstrated with five differently shaped OFEs. The intensity of measured bioluminescence was minimally influenced by the OFE shape, possessing transmittances between 1.41% and 5.00%. OFE probes layered with P. putida TVA8 were used to monitor liquid toluene over a two-week period. It was demonstrated that OFE probes layered with positively induced P. putida TVA8 bioreporters were reliable detectors of toluene. A toluene concentration of 26.5 mg/L was detected after <30 min after immersion of the probe in the toluene solution. Additional experiments also immobilized constitutively bioluminescent cells of E. coli 652T7, on OFEs with polyethyleneimine (PEI). These OFEs were repetitively induced with Lauria-Bertani (LB) nutrient medium. Bioluminescence appeared 15 minutes after immersion of the OFE in LB. A change in pH from 7 to 6 resulted in a decrease in bioluminescence that was not restored following additional nutrient inductions at pH 7. The E. coli 652T7 OFE probe was therefore sensitive to negative influences but could not be repetitively used.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21012493
003      
CZ-PrNML
005      
20210507104502.0
007      
ta
008      
210420s2020 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/s20113237 $2 doi
035    __
$a (PubMed)32517218
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Zajíc, Jakub $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 27201 Kladno, Czech Republic $u Center for Environmental Biotechnology, University of Tennessee, Knoxville, TN 37996, USA $u Department of Cardiology, Regional Hospital Liberec, 46063 Liberec, Czech Republic
245    10
$a Repetitive Detection of Aromatic Hydrocarbon Contaminants with Bioluminescent Bioreporters Attached on Tapered Optical Fiber Elements / $c J. Zajíc, S. Ripp, J. Trögl, G. Kuncová, M. Pospíšilová
520    9_
$a In this study, we show the repetitive detection of toluene on a tapered optical fiber element (OFE) with an attached layer of Pseudomonas putida TVA8 bioluminescent bioreporters. The bioluminescent cell layer was attached on polished quartz modified with (3-aminopropyl)triethoxysilane (APTES). The repeatability of the preparation of the optical probe and its use was demonstrated with five differently shaped OFEs. The intensity of measured bioluminescence was minimally influenced by the OFE shape, possessing transmittances between 1.41% and 5.00%. OFE probes layered with P. putida TVA8 were used to monitor liquid toluene over a two-week period. It was demonstrated that OFE probes layered with positively induced P. putida TVA8 bioreporters were reliable detectors of toluene. A toluene concentration of 26.5 mg/L was detected after <30 min after immersion of the probe in the toluene solution. Additional experiments also immobilized constitutively bioluminescent cells of E. coli 652T7, on OFEs with polyethyleneimine (PEI). These OFEs were repetitively induced with Lauria-Bertani (LB) nutrient medium. Bioluminescence appeared 15 minutes after immersion of the OFE in LB. A change in pH from 7 to 6 resulted in a decrease in bioluminescence that was not restored following additional nutrient inductions at pH 7. The E. coli 652T7 OFE probe was therefore sensitive to negative influences but could not be repetitively used.
650    12
$a biosenzitivní techniky $7 D015374
650    _2
$a Escherichia coli $7 D004926
650    _2
$a aromatické uhlovodíky $x analýza $7 D006841
650    12
$a luminiscenční měření $7 D008163
650    _2
$a optická vlákna $7 D055100
650    _2
$a Pseudomonas putida $7 D016958
650    _2
$a toluen $x analýza $7 D014050
655    _2
$a časopisecké články $7 D016428
700    1_
$a Ripp, Steven $u Center for Environmental Biotechnology, University of Tennessee, Knoxville, TN 37996, USA
700    1_
$a Trögl, Josef $u Faculty of Environment, Jan Evangelista Purkyně University in Ústí nad Labem, 40096 Ústí nad Labem, Czech Republic
700    1_
$a Kuncová, Gabriela $u Faculty of Environment, Jan Evangelista Purkyně University in Ústí nad Labem, 40096 Ústí nad Labem, Czech Republic $u Institute of Chemical Process Fundamentals of the ASCR, 16502 Prague, Czech Republic
700    1_
$a Pospíšilová, Marie $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 27201 Kladno, Czech Republic
773    0_
$w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 20, č. 11 (2020)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32517218 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210420 $b ABA008
991    __
$a 20210507104501 $b ABA008
999    __
$a ok $b bmc $g 1650788 $s 1132872
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 20 $c 11 $e 20200606 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
GRA    __
$a SGS17/110/OHK4/1T/17 $p České Vysoké Učení Technické v Praze
GRA    __
$a SGS18/097/OHK4/1T/17 $p České Vysoké Učení Technické v Praze
GRA    __
$a CZ.02.1.01/0.0/0.0/17_048/0007435 $p Ministerstvo Školství, Mládeže a Tělovýchovy
LZP    __
$a Pubmed-20210420

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...