Protective aspects in contactless infrared thermography fever screening

Vladan Bernard, Erik Staffa, Aleš Bourek, Marek Dostál, Vojtěch Mornstein, Tomáš Jůza, Jana Pokorná

. 2020 ; 50 (3) : 95-100.

Jazyk angličtina Země Česko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc21014495

Main symptoms found in patients with same diseases as for example COVID-19 is febrile. The infrared thermography (IRT) represents a fast measurement in case of screening in public places. One of the limitations of IRT is the resolution of sensor, which has close connection with the distance between camera and ROI. To maximize the effectivity of resolution of the camera is to reduce the distance from the object. The aim of presented study showed the possibility how to protect the camera or medical staff that operates the device against potential infection or contamination from the person with infection. Two protective foils of different thickness (40 μm; 9 μm) were tested as a barrier between the IRT and the ROI (black body model and human face). Even though the results have shown that the transparent foils decrease linearly the measured value of the temperature, it can be used as a protective barrier between IRT and the object if an appropriate recalculation is done during analysis of IRT images. Results are acceptable in the case of 9μm foil especially. The authors see this possibility as a minor concession from IRT standards but as a great help in health protection. The transparent foil can be used as protective barrier of the infrared camera.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21014495
003      
CZ-PrNML
005      
20210616210337.0
007      
ta
008      
210510s2020 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2020.3.03 $2 doi
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Bernard, Vladan $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno $7 mub2014807571
245    10
$a Protective aspects in contactless infrared thermography fever screening / $c Vladan Bernard, Erik Staffa, Aleš Bourek, Marek Dostál, Vojtěch Mornstein, Tomáš Jůza, Jana Pokorná
520    9_
$a Main symptoms found in patients with same diseases as for example COVID-19 is febrile. The infrared thermography (IRT) represents a fast measurement in case of screening in public places. One of the limitations of IRT is the resolution of sensor, which has close connection with the distance between camera and ROI. To maximize the effectivity of resolution of the camera is to reduce the distance from the object. The aim of presented study showed the possibility how to protect the camera or medical staff that operates the device against potential infection or contamination from the person with infection. Two protective foils of different thickness (40 μm; 9 μm) were tested as a barrier between the IRT and the ROI (black body model and human face). Even though the results have shown that the transparent foils decrease linearly the measured value of the temperature, it can be used as a protective barrier between IRT and the object if an appropriate recalculation is done during analysis of IRT images. Results are acceptable in the case of 9μm foil especially. The authors see this possibility as a minor concession from IRT standards but as a great help in health protection. The transparent foil can be used as protective barrier of the infrared camera.
650    _2
$a lidé $7 D006801
650    12
$a tělesná teplota $7 D001831
650    12
$a termografie $x metody $7 D013817
650    _2
$a infračervené záření $7 D007259
650    _2
$a COVID-19 $x prevence a kontrola $7 D000086382
650    _2
$a horečka $x diagnóza $7 D005334
650    _2
$a kůže $x diagnostické zobrazování $7 D012867
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Staffa, Erik $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno $7 mub2014808981
700    1_
$a Bourek, Aleš, $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno $d 1957- $7 jn20010309814
700    1_
$a Dostál, Marek $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno $7 xx0260524
700    1_
$a Mornstein, Vojtěch, $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno $d 1955- $7 jn99240000734
700    1_
$a Jůza, Tomáš $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno $7 xx0260502
700    1_
$a Pokorná, Jana $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno $7 _AN110515
773    0_
$w MED00011033 $t Lékař a technika $x 0301-5491 $g Roč. 50, č. 3 (2020), s. 95-100
856    41
$u https://www.prolekare.cz/casopisy/lekar-a-technika/2020-3-31/protective-aspects-in-contactless-infrared-thermography-fever-screening-126790 $y plný text volně dostupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y p $z 0
990    __
$a 20210510 $b ABA008
991    __
$a 20210616210335 $b ABA008
999    __
$a ok $b bmc $g 1655142 $s 1134887
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 50 $c 3 $d 95-100 $i 0301-5491 $m Lékař a technika $x MED00011033 $y 126790
LZP    __
$c NLK109 $d 20210616 $b NLK111 $a Meditorial-20210510

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...