The role of pKa, log P of analytes, and protein matrix in solid-phase extraction using native and coated nanofibrous and microfibrous polymers prepared via meltblowing and combined meltblowing/electrospinning technologies

H. Raabová, J. Erben, J. Chvojka, P. Solich, F. Švec, D. Šatínský

. 2021 ; 232 (-) : 122470. [pub] 20210430

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21018364

Effect of physicochemical properties including dissociation constant (pKa) and partition coefficient (log P) of the compounds on their extraction efficiency in sample preparation using fibrous polymer sorbents has been demonstrated. Poly-ε-caprolactone as meltblown/electrospun composite fibers, and polypropylene, polyethylene, poly(3-hydroxybutyrate), poly(lactic acid), and polyamide 6 in the meltblown fiber format were used as sorbents in solid-phase extraction. In addition, the polycaprolactone fibers were coated with dopamine, dopamine combined with heparin, and tannin, respectively, to modify their extraction properties. These fibers that were not yet used for extractions and the unique combination of sorbents and analytes significantly extends the scope of nanofibrous extraction. The extraction efficiency was determined using model pharmaceuticals including acetylsalicylic acid, moxonidine, metoprolol, propranolol, propafenone, diltiazem, atorvastatin, and amiodarone. These model compounds displayed the widest differences in both pKa and log P values. The extraction efficiency of some of the fibers reached 96.64%. Coating of polycaprolactone fibers with dopamine significantly improved extraction efficiency of slightly retained metoprolol while moxonidine was not retained on any sorbent. The fibrous sorbents were also tested for extraction of pharmaceuticals in bovine serum albumin and human serum, respectively, to demonstrate their capability to extract them from a complex protein-containing matrix. The clean-up efficiency of our fibers was compared with that of a commercial restricted access media (RAM) C-18 alkyl-diol silica column. Our technique is in accordance with the requirements of modern sample preparation techniques.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21018364
003      
CZ-PrNML
005      
20210830095943.0
007      
ta
008      
210728s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2021.122470 $2 doi
035    __
$a (PubMed)34074440
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Raabová, Hedvika $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 50005, Hradec Králové, Czech Republic
245    14
$a The role of pKa, log P of analytes, and protein matrix in solid-phase extraction using native and coated nanofibrous and microfibrous polymers prepared via meltblowing and combined meltblowing/electrospinning technologies / $c H. Raabová, J. Erben, J. Chvojka, P. Solich, F. Švec, D. Šatínský
520    9_
$a Effect of physicochemical properties including dissociation constant (pKa) and partition coefficient (log P) of the compounds on their extraction efficiency in sample preparation using fibrous polymer sorbents has been demonstrated. Poly-ε-caprolactone as meltblown/electrospun composite fibers, and polypropylene, polyethylene, poly(3-hydroxybutyrate), poly(lactic acid), and polyamide 6 in the meltblown fiber format were used as sorbents in solid-phase extraction. In addition, the polycaprolactone fibers were coated with dopamine, dopamine combined with heparin, and tannin, respectively, to modify their extraction properties. These fibers that were not yet used for extractions and the unique combination of sorbents and analytes significantly extends the scope of nanofibrous extraction. The extraction efficiency was determined using model pharmaceuticals including acetylsalicylic acid, moxonidine, metoprolol, propranolol, propafenone, diltiazem, atorvastatin, and amiodarone. These model compounds displayed the widest differences in both pKa and log P values. The extraction efficiency of some of the fibers reached 96.64%. Coating of polycaprolactone fibers with dopamine significantly improved extraction efficiency of slightly retained metoprolol while moxonidine was not retained on any sorbent. The fibrous sorbents were also tested for extraction of pharmaceuticals in bovine serum albumin and human serum, respectively, to demonstrate their capability to extract them from a complex protein-containing matrix. The clean-up efficiency of our fibers was compared with that of a commercial restricted access media (RAM) C-18 alkyl-diol silica column. Our technique is in accordance with the requirements of modern sample preparation techniques.
650    _2
$a lidé $7 D006801
650    12
$a nanovlákna $7 D057139
650    _2
$a polymery $7 D011108
650    _2
$a proteiny $7 D011506
650    _2
$a extrakce na pevné fázi $7 D052616
655    _2
$a časopisecké články $7 D016428
700    1_
$a Erben, Jakub $u The Technical University of Liberec, Faculty of Textile Engineering, Department of Nonwovens and Nanofibrous Materials, Studentská 1402/2, 46001, Liberec 1, Czech Republic
700    1_
$a Chvojka, Jiří $u The Technical University of Liberec, Faculty of Textile Engineering, Department of Nonwovens and Nanofibrous Materials, Studentská 1402/2, 46001, Liberec 1, Czech Republic
700    1_
$a Solich, Petr $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 50005, Hradec Králové, Czech Republic
700    1_
$a Švec, František $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 50005, Hradec Králové, Czech Republic
700    1_
$a Šatínský, Dalibor $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 50005, Hradec Králové, Czech Republic. Electronic address: satinsky@faf.cuni.cz
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 232, č. - (2021), s. 122470
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34074440 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830095943 $b ABA008
999    __
$a ok $b bmc $g 1689484 $s 1138808
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 232 $c - $d 122470 $e 20210430 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...