-
Something wrong with this record ?
Effects of motion correction, sampling rate and parametric modelling in dynamic contrast enhanced MRI of the temporomandibular joint in children affected with juvenile idiopathic arthritis
L. Starck, E. Andersen, O. Macíček, O. Angenete, TA. Augdal, K. Rosendahl, R. Jiřík, R. Grüner
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Artifacts MeSH
- Child MeSH
- Arthritis, Juvenile diagnostic imaging MeSH
- Humans MeSH
- Magnetic Resonance Imaging * MeSH
- Adolescent MeSH
- Image Processing, Computer-Assisted * MeSH
- Movement * MeSH
- Child, Preschool MeSH
- Cross-Sectional Studies MeSH
- Sensitivity and Specificity MeSH
- Models, Statistical * MeSH
- Temporomandibular Joint diagnostic imaging MeSH
- Check Tag
- Child MeSH
- Humans MeSH
- Adolescent MeSH
- Male MeSH
- Child, Preschool MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The temporomandibular joint (TMJ) is typically involved in 45-87% of children with Juvenile Idiopathic Arthritis (JIA). Accurate diagnosis of JIA is difficult as various clinical tests, including MRI, disagree. The purpose of this study is to optimize the methodological aspects of Dynamic Contrast Enhanced (DCE) MRI of the TMJ in children. In this cross-sectional study, including data from 73 JIA affected children, aged 6-15 years, effects of motion correction, sampling rate and parametric modelling on DCE-MRI data is investigated. Consensus among three radiologists determined the regions of interest. Quantitative perfusion parameters were estimated using four perfusion models; the Adiabatic Approximation to Tissue Homogeneity (AATH), Distributed Capillary Adiabatic Tissue Homogeneity (DCATH), Gamma Capillary Transit Time (GCTT) and Two Compartment Exchange (2CXM) models. Effects of motion correction were evaluated by a sum of least squares between corrected raw data and the GCTT model. The effect of systematically down sampling the raw data was tested. The sum of least squares was computed across all pharmacokinetic models. Relative difference perfusion parameters between the left and right TMJ were used for an unsupervised k-means based stratification of the data based on a principal component analysis, as well as for a supervised random forest classification. Diagnostic sensitivity and specificity were computed relative to structural image scorings. Paired sample t-tests, as well as ANOVA tests, were used (significant threshold: p < 0.05) with Tukeys post hoc test. High-level elastic motion correction provides the best least square fit to the GCTT model (percental improvement: 72-84%). A 4 s sampling rate captures more of the potentially disease relevant signal variations. The various parametric models all leave comparable residues (relative standard deviation: 3.4%). In further evaluation of DCE-MRI as a potential diagnostic tool for JIA a high-level elastic motion correction scheme should be adopted, with a sampling rate of at least 4 s. Results suggest that DCE-MRI data can be a valuable part in JIA diagnostics in the TMJ.
Department of Clinical Engineering Haukeland University Hospital Bergen Norway
Department of Clinical Medicine UiT The Arctic University of Norway Norway
Department of Physics and Technology University of Bergen Bergen Norway
Department of Radiology and Nuclear Medicine St Olav Hospital HF Trondheim Norway
Department of Radiology Haukeland University Hospital Bergen Norway
Institute of Scientific Instruments of the Czech Academy of Sciences Brno Czechia
Mohn Medical Imaging and Visualization Centre Haukeland University Hospital Bergen Norway
Section for Paediatric Radiology University Hospital of North Norway Tromsø Norway
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21018940
- 003
- CZ-PrNML
- 005
- 20210830100521.0
- 007
- ta
- 008
- 210728s2021 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.mri.2020.12.014 $2 doi
- 035 __
- $a (PubMed)33359424
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Starck, Lea $u Department of Physics and Technology, University of Bergen, Bergen, Norway; Mohn Medical Imaging and Visualization Centre, Haukeland University Hospital, Bergen, Norway. Electronic address: lea.starck@uib.no
- 245 10
- $a Effects of motion correction, sampling rate and parametric modelling in dynamic contrast enhanced MRI of the temporomandibular joint in children affected with juvenile idiopathic arthritis / $c L. Starck, E. Andersen, O. Macíček, O. Angenete, TA. Augdal, K. Rosendahl, R. Jiřík, R. Grüner
- 520 9_
- $a The temporomandibular joint (TMJ) is typically involved in 45-87% of children with Juvenile Idiopathic Arthritis (JIA). Accurate diagnosis of JIA is difficult as various clinical tests, including MRI, disagree. The purpose of this study is to optimize the methodological aspects of Dynamic Contrast Enhanced (DCE) MRI of the TMJ in children. In this cross-sectional study, including data from 73 JIA affected children, aged 6-15 years, effects of motion correction, sampling rate and parametric modelling on DCE-MRI data is investigated. Consensus among three radiologists determined the regions of interest. Quantitative perfusion parameters were estimated using four perfusion models; the Adiabatic Approximation to Tissue Homogeneity (AATH), Distributed Capillary Adiabatic Tissue Homogeneity (DCATH), Gamma Capillary Transit Time (GCTT) and Two Compartment Exchange (2CXM) models. Effects of motion correction were evaluated by a sum of least squares between corrected raw data and the GCTT model. The effect of systematically down sampling the raw data was tested. The sum of least squares was computed across all pharmacokinetic models. Relative difference perfusion parameters between the left and right TMJ were used for an unsupervised k-means based stratification of the data based on a principal component analysis, as well as for a supervised random forest classification. Diagnostic sensitivity and specificity were computed relative to structural image scorings. Paired sample t-tests, as well as ANOVA tests, were used (significant threshold: p < 0.05) with Tukeys post hoc test. High-level elastic motion correction provides the best least square fit to the GCTT model (percental improvement: 72-84%). A 4 s sampling rate captures more of the potentially disease relevant signal variations. The various parametric models all leave comparable residues (relative standard deviation: 3.4%). In further evaluation of DCE-MRI as a potential diagnostic tool for JIA a high-level elastic motion correction scheme should be adopted, with a sampling rate of at least 4 s. Results suggest that DCE-MRI data can be a valuable part in JIA diagnostics in the TMJ.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a juvenilní artritida $x diagnostické zobrazování $7 D001171
- 650 _2
- $a artefakty $7 D016477
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a předškolní dítě $7 D002675
- 650 _2
- $a průřezové studie $7 D003430
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a počítačové zpracování obrazu $7 D007091
- 650 12
- $a magnetická rezonanční tomografie $7 D008279
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a statistické modely $7 D015233
- 650 12
- $a pohyb $7 D009068
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a temporomandibulární kloub $x diagnostické zobrazování $7 D013704
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Andersen, Erling $u Mohn Medical Imaging and Visualization Centre, Haukeland University Hospital, Bergen, Norway; Department of Clinical Engineering, Haukeland University Hospital, Bergen, Norway. Electronic address: erling.andersen@helse-bergen.no
- 700 1_
- $a Macíček, Ondřej $u Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia. Electronic address: macicek@isibrno.cz
- 700 1_
- $a Angenete, Oskar $u Department of Radiology and Nuclear Medicine, St. Olav Hospital HF, Trondheim, Norway; Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway. Electronic address: Oskar.Angenete@stolav.no
- 700 1_
- $a Augdal, Thomas A $u Section for Paediatric Radiology, University Hospital of North Norway, Tromsø, Norway; Department of Clinical Medicine, UiT The Arctic University of Norway, Norway. Electronic address: Thomas.Angell.Augdal@unn.no
- 700 1_
- $a Rosendahl, Karen $u Department of Clinical Medicine, UiT The Arctic University of Norway, Norway. Electronic address: Karen.Rosendahl@unn.no
- 700 1_
- $a Jiřík, Radovan $u Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia. Electronic address: jirik@isibrno.cz
- 700 1_
- $a Grüner, Renate $u Department of Physics and Technology, University of Bergen, Bergen, Norway; Mohn Medical Imaging and Visualization Centre, Haukeland University Hospital, Bergen, Norway; Department of Radiology, Haukeland University Hospital, Bergen, Norway. Electronic address: eli.renate.gruner@helse-bergen.no
- 773 0_
- $w MED00003171 $t Magnetic resonance imaging $x 1873-5894 $g Roč. 77, č. - (2021), s. 204-212
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33359424 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100521 $b ABA008
- 999 __
- $a ok $b bmc $g 1689894 $s 1139386
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 77 $c - $d 204-212 $e 20210113 $i 1873-5894 $m Magnetic resonance imaging $n Magn Reson Imaging $x MED00003171
- LZP __
- $a Pubmed-20210728