Ex-vivo biomechanical testing of pig femur diaphysis B type fracture fixed by novel biodegradable bone glue

M. Krtička, L. Michlovská, V. Nekuda, P. Poláček, K. Valová, J. Žídek, J. Kaiser, T. Zikmund, L. Vojtová

. 2021 ; 115 (-) : 104249. [pub] 20201205

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019153

AIMS: The aim of this study was to answer the question whether our newly developed injectable biodegradable "self-setting" polymer-composite as a bone adhesive is a good "bone-glue" candidate to efficiently fix comminuted fractures of pig femoral bones used as an ex-vivo experimental model. METHODS: Mechanical properties of adhesive prepared from α-tricalcium phosphate (TCP) powder and thermogelling copolymer were optimized by selecting the appropriate composition with adhesion enhancers based on dopamine and sodium iodinate. Setting time and injectability were controlled by rheology. Ex-vivo experiments of fixed pig bones were provided in terms of either the three-point bending test of bending wedge type fractured pig femurs (with LCP) or the axial compression test of 45° oblique fractured femurs (without LCP) in physiological saline solution at 37 °C. Fractured bones treated with optimized adhesive before and after bending tests were imaged by X-ray microtomography (μCT). RESULTS: Based on the rheological measurement, the adhesive modified with both dopamine and sodium iodinate exhibited optimal thixotropic properties required for injection via thin 22 G needle. This optimal adhesive composition showed an 8 min lag phase (processing time) followed by fast increase in storage modulus at 37 °C up to 1 GPa within 110 min. Self-setting of dopamine/iodinate modified adhesive was completed in 48 h exhibiting the maximum strength at compression of 7.98 MPa ± 1.39 MPa. Whereas unmodified adhesive failed in glue-to-bone adhesion, dopamine and dopamine/iodinate modified adhesive used for 45° oblique fracture fixation showed good and similar strength at compression (3.05 and 2.79 MPa, respectively). However, significantly higher elasticity of about 250% exhibited adhesive with iodinate enhancer. Moreover, mechanical properties of B2 fractures fixed with both LCP and dopamine/iodinate adhesive were approaching closely to the properties of original bone. Excellent adhesion between the adhesive and the bone fragments was proved by μCT. CONCLUSION: The polymer-composite bone adhesive modified with dopamine/iodinate exhibited very good fixation ability of femoral artificial comminuted fractures in an experimental model.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019153
003      
CZ-PrNML
005      
20210830100730.0
007      
ta
008      
210728s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jmbbm.2020.104249 $2 doi
035    __
$a (PubMed)33340777
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Krtička, Milan $u Trauma Surgery Department, The University Hospital Brno, Jihlavská 20, 625 00, Brno, Czech Republic; Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic. Electronic address: krticka.milan@fnbrno.cz
245    10
$a Ex-vivo biomechanical testing of pig femur diaphysis B type fracture fixed by novel biodegradable bone glue / $c M. Krtička, L. Michlovská, V. Nekuda, P. Poláček, K. Valová, J. Žídek, J. Kaiser, T. Zikmund, L. Vojtová
520    9_
$a AIMS: The aim of this study was to answer the question whether our newly developed injectable biodegradable "self-setting" polymer-composite as a bone adhesive is a good "bone-glue" candidate to efficiently fix comminuted fractures of pig femoral bones used as an ex-vivo experimental model. METHODS: Mechanical properties of adhesive prepared from α-tricalcium phosphate (TCP) powder and thermogelling copolymer were optimized by selecting the appropriate composition with adhesion enhancers based on dopamine and sodium iodinate. Setting time and injectability were controlled by rheology. Ex-vivo experiments of fixed pig bones were provided in terms of either the three-point bending test of bending wedge type fractured pig femurs (with LCP) or the axial compression test of 45° oblique fractured femurs (without LCP) in physiological saline solution at 37 °C. Fractured bones treated with optimized adhesive before and after bending tests were imaged by X-ray microtomography (μCT). RESULTS: Based on the rheological measurement, the adhesive modified with both dopamine and sodium iodinate exhibited optimal thixotropic properties required for injection via thin 22 G needle. This optimal adhesive composition showed an 8 min lag phase (processing time) followed by fast increase in storage modulus at 37 °C up to 1 GPa within 110 min. Self-setting of dopamine/iodinate modified adhesive was completed in 48 h exhibiting the maximum strength at compression of 7.98 MPa ± 1.39 MPa. Whereas unmodified adhesive failed in glue-to-bone adhesion, dopamine and dopamine/iodinate modified adhesive used for 45° oblique fracture fixation showed good and similar strength at compression (3.05 and 2.79 MPa, respectively). However, significantly higher elasticity of about 250% exhibited adhesive with iodinate enhancer. Moreover, mechanical properties of B2 fractures fixed with both LCP and dopamine/iodinate adhesive were approaching closely to the properties of original bone. Excellent adhesion between the adhesive and the bone fragments was proved by μCT. CONCLUSION: The polymer-composite bone adhesive modified with dopamine/iodinate exhibited very good fixation ability of femoral artificial comminuted fractures in an experimental model.
650    _2
$a zvířata $7 D000818
650    _2
$a biomechanika $7 D001696
650    12
$a kostní cementy $7 D001843
650    _2
$a kostní destičky $7 D001860
650    _2
$a diafýzy $7 D018483
650    12
$a fraktury femuru $x diagnostické zobrazování $7 D005264
650    _2
$a femur $x diagnostické zobrazování $7 D005269
650    _2
$a fixace fraktury $7 D005592
650    _2
$a vnitřní fixace fraktury $7 D005593
650    _2
$a prasata $7 D013552
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Michlovská, Lenka $u Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00, Brno, Czech Republic. Electronic address: lenka.michlovska@ceitec.vutbr.cz
700    1_
$a Nekuda, Vladimír $u Trauma Surgery Department, The University Hospital Brno, Jihlavská 20, 625 00, Brno, Czech Republic; Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic. Electronic address: nekuda.vladimir@fnbrno.cz
700    1_
$a Poláček, Petr $u Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00, Brno, Czech Republic. Electronic address: petr.polacek@ceitec.vutbr.cz
700    1_
$a Valová, Kristýna $u Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00, Brno, Czech Republic. Electronic address: kristyna.valova@ceitec.vutbr.cz
700    1_
$a Žídek, Jan $u Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00, Brno, Czech Republic. Electronic address: jan.zidek@ceitec.vutbr.cz
700    1_
$a Kaiser, Jozef $u Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00, Brno, Czech Republic. Electronic address: jozef.kaiser@ceitec.vutbr.cz
700    1_
$a Zikmund, Tomáš $u Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00, Brno, Czech Republic. Electronic address: tomas.zikmund@ceitec.vutbr.cz
700    1_
$a Vojtová, Lucy $u Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00, Brno, Czech Republic. Electronic address: lucy.vojtova@ceitec.vutbr.cz
773    0_
$w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 115, č. - (2021), s. 104249
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33340777 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830100730 $b ABA008
999    __
$a ok $b bmc $g 1690068 $s 1139599
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 115 $c - $d 104249 $e 20201205 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...