• Something wrong with this record ?

A novel proton counting detector and method for the validation of tissue and implant material maps for Monte Carlo dose calculation

S. Charyyev, CW. Chang, J. Harms, C. Oancea, ST. Yoon, X. Yang, T. Zhang, J. Zhou, L. Lin

. 2021 ; 66 (4) : 045003. [pub] 20210202

Language English Country Great Britain

Document type Journal Article

The presence of artificial implants complicates the delivery of proton therapy due to inaccurate characterization of both the implant and the surrounding tissues. In this work, we describe a method to characterize implant and human tissue mimicking materials in terms of relative stopping power (RSP) using a novel proton counting detector. Each proton is tracked by directly measuring the deposited energy along the proton track using a fast, pixelated spectral detector AdvaPIX-TPX3 (TPX3). We considered three scenarios to characterize the RSPs. First, in-air measurements were made in the presence of metal rods (Al, Ti and CoCr) and bone. Then, measurements of energy perturbations in the presence of metal implants and bone in an anthropomorphic phantom were performed. Finally, sampling of cumulative stopping power (CSP) of the phantom were made at different locations of the anthropomorphic phantom. CSP and RSP information were extracted from energy spectra at each beam path. To quantify the RSP of metal rods we used the shift in the most probable energy (MPE) of CSP from the reference CSP without a rod. Overall, the RSPs were determined as 1.48, 2.06, 3.08, and 5.53 from in-air measurements; 1.44, 1.97, 2.98, and 5.44 from in-phantom measurements, for bone, Al, Ti and CoCr, respectively. Additionally, we sampled CSP for multiple paths of the anthropomorphic phantom ranging from 18.63 to 25.23 cm deriving RSP of soft tissues and bones in agreement within 1.6% of TOPAS simulations. Using minimum error of these multiple CSP, optimal mass densities were derived for soft tissue and bone and they are within 1% of vendor-provided nominal densities. The preliminary data obtained indicates the proposed novel method can be used for the validation of material and density maps, required by proton Monte Carlo Dose calculation, provided by competing multi-energy computed tomography and metal artifact reduction techniques.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019294
003      
CZ-PrNML
005      
20210830100852.0
007      
ta
008      
210728s2021 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1088/1361-6560/abd22e $2 doi
035    __
$a (PubMed)33296888
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Charyyev, Serdar $u Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, United States of America
245    12
$a A novel proton counting detector and method for the validation of tissue and implant material maps for Monte Carlo dose calculation / $c S. Charyyev, CW. Chang, J. Harms, C. Oancea, ST. Yoon, X. Yang, T. Zhang, J. Zhou, L. Lin
520    9_
$a The presence of artificial implants complicates the delivery of proton therapy due to inaccurate characterization of both the implant and the surrounding tissues. In this work, we describe a method to characterize implant and human tissue mimicking materials in terms of relative stopping power (RSP) using a novel proton counting detector. Each proton is tracked by directly measuring the deposited energy along the proton track using a fast, pixelated spectral detector AdvaPIX-TPX3 (TPX3). We considered three scenarios to characterize the RSPs. First, in-air measurements were made in the presence of metal rods (Al, Ti and CoCr) and bone. Then, measurements of energy perturbations in the presence of metal implants and bone in an anthropomorphic phantom were performed. Finally, sampling of cumulative stopping power (CSP) of the phantom were made at different locations of the anthropomorphic phantom. CSP and RSP information were extracted from energy spectra at each beam path. To quantify the RSP of metal rods we used the shift in the most probable energy (MPE) of CSP from the reference CSP without a rod. Overall, the RSPs were determined as 1.48, 2.06, 3.08, and 5.53 from in-air measurements; 1.44, 1.97, 2.98, and 5.44 from in-phantom measurements, for bone, Al, Ti and CoCr, respectively. Additionally, we sampled CSP for multiple paths of the anthropomorphic phantom ranging from 18.63 to 25.23 cm deriving RSP of soft tissues and bones in agreement within 1.6% of TOPAS simulations. Using minimum error of these multiple CSP, optimal mass densities were derived for soft tissue and bone and they are within 1% of vendor-provided nominal densities. The preliminary data obtained indicates the proposed novel method can be used for the validation of material and density maps, required by proton Monte Carlo Dose calculation, provided by competing multi-energy computed tomography and metal artifact reduction techniques.
650    _2
$a lidé $7 D006801
650    12
$a metoda Monte Carlo $7 D009010
650    12
$a fantomy radiodiagnostické $7 D019047
650    12
$a protézy a implantáty $7 D019736
650    _2
$a protonová terapie $x přístrojové vybavení $7 D061766
655    _2
$a časopisecké články $7 D016428
700    1_
$a Chang, Chih-Wei $u Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, United States of America
700    1_
$a Harms, Joseph $u Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, United States of America
700    1_
$a Oancea, Cristina $u ADVACAM, Prague, Czech Republic
700    1_
$a Yoon, S Tim $u Department of Orthopaedics, Emory University, Atlanta, GA, United States of America
700    1_
$a Yang, Xiaofeng $u Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, United States of America
700    1_
$a Zhang, Tiezhi $u Department of Radiation Oncology, Washington University in St. Louis School of Medicine, St. Louis, MO, United States of America
700    1_
$a Zhou, Jun $u Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, United States of America
700    1_
$a Lin, Liyong $u Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, United States of America
773    0_
$w MED00003821 $t Physics in medicine and biology $x 1361-6560 $g Roč. 66, č. 4 (2021), s. 045003
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33296888 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830100853 $b ABA008
999    __
$a ok $b bmc $g 1690179 $s 1139740
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 66 $c 4 $d 045003 $e 20210202 $i 1361-6560 $m Physics in medicine and biology $n Phys Med Biol $x MED00003821
LZP    __
$a Pubmed-20210728

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...