Out-of-field doses for scanning proton radiotherapy of shallowly located paediatric tumours-a comparison of range shifter and 3D printed compensator
A. Wochnik, L. Stolarczyk, I. Ambrožová, M. Davídková, M. De Saint-Hubert, S. Domański, C. Domingo, Ž. Knežević, R. Kopeć, M. Kuć, M. Majer, N. Mojżeszek, V. Mares, I. Martínez-Rovira, MÁ. Caballero-Pacheco, E. Pyszka, J. Swakoń, S. Trinkl, M....
Language English Country Great Britain
Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Printing, Three-Dimensional * MeSH
- Radiotherapy Dosage MeSH
- Radiation Dosage * MeSH
- Child MeSH
- Phantoms, Imaging MeSH
- Humans MeSH
- Monte Carlo Method MeSH
- Brain Neoplasms radiotherapy MeSH
- Neutrons MeSH
- Computer Simulation MeSH
- Proton Therapy instrumentation MeSH
- Check Tag
- Child MeSH
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
The lowest possible energy of proton scanning beam in cyclotron proton therapy facilities is typically between 60 and 100 MeV. Treatment of superficial lesions requires a pre-absorber to deliver doses to shallower volumes. In most of the cases a range shifter (RS) is used, but as an alternative solution, a patient-specific 3D printed proton beam compensator (BC) can be applied. A BC enables further reduction of the air gap and consequently reduction of beam scattering. Such pre-absorbers are additional sources of secondary radiation. The aim of this work was the comparison of RS and BC with respect to out-of-field doses for a simulated treatment of superficial paediatric brain tumours. EURADOS WG9 performed comparative measurements of scattered radiation in the Proteus C-235 IBA facility (Cyclotron Centre Bronowice at the Institute of Nuclear Physics, CCB IFJ PAN, Kraków, Poland) using two anthropomorphic phantoms-5 and 10 yr old-for a superficial target in the brain. Both active detectors located inside the therapy room, and passive detectors placed inside the phantoms were used. Measurements were supplemented by Monte Carlo simulation of the radiation transport. For the applied 3D printed pre-absorbers, out-of-field doses from both secondary photons and neutrons were lower than for RS. Measurements with active environmental dosimeters at five positions inside the therapy room indicated that the RS/BC ratio of the out-of-field dose was also higher than one, with a maximum of 1.7. Photon dose inside phantoms leads to higher out-of-field doses for RS than BC to almost all organs with the highest RS/BC ratio 12.5 and 13.2 for breasts for 5 and 10 yr old phantoms, respectively. For organs closest to the isocentre such as the thyroid, neutron doses were lower for BC than RS due to neutrons moderation in the target volume, but for more distant organs like bladder-conversely-lower doses for RS than BC were observed. The use of 3D printed BC as the pre-absorber placed in the near vicinity of patient in the treatment of superficial tumours does not result in the increase of secondary radiation compared to the treatment with RS, placed far from the patient.
Belgium Nuclear Research Centre Boeretang 200 Mol BE 2400 Belgium
Dansk Center for Partikelterapi Palle Juul Jensens Boulevard 25 8200 Aarhus N Denmark
Departament de Física Universitat Autònoma de Barcelona Bellaterra E 08193 Spain
Institute of Nuclear Physics PAN Radzikowskiego 152 Krakow 31 342 Poland
National Centre for Nuclear Research Otwock Świerk 05 400 Poland
Ruđer Bošković Institute Bijenička c 54 Zagreb 10000 Croatia
Skandionkliniken von Kraemers Allé 26 Uppsala 752 37 Sweden
Technische Universität München Physik Department Garching 85748 Germany
University of Newcastle upon Tyne Tyne and Wear Newcastle upon Tyne NE1 7RU United Kingdom
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019404
- 003
- CZ-PrNML
- 005
- 20210830100949.0
- 007
- ta
- 008
- 210728s2021 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1088/1361-6560/abcb1f $2 doi
- 035 __
- $a (PubMed)33202399
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Wochnik, A $u Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342, Poland
- 245 10
- $a Out-of-field doses for scanning proton radiotherapy of shallowly located paediatric tumours-a comparison of range shifter and 3D printed compensator / $c A. Wochnik, L. Stolarczyk, I. Ambrožová, M. Davídková, M. De Saint-Hubert, S. Domański, C. Domingo, Ž. Knežević, R. Kopeć, M. Kuć, M. Majer, N. Mojżeszek, V. Mares, I. Martínez-Rovira, MÁ. Caballero-Pacheco, E. Pyszka, J. Swakoń, S. Trinkl, M. Tisi, R. Harrison, P. Olko
- 520 9_
- $a The lowest possible energy of proton scanning beam in cyclotron proton therapy facilities is typically between 60 and 100 MeV. Treatment of superficial lesions requires a pre-absorber to deliver doses to shallower volumes. In most of the cases a range shifter (RS) is used, but as an alternative solution, a patient-specific 3D printed proton beam compensator (BC) can be applied. A BC enables further reduction of the air gap and consequently reduction of beam scattering. Such pre-absorbers are additional sources of secondary radiation. The aim of this work was the comparison of RS and BC with respect to out-of-field doses for a simulated treatment of superficial paediatric brain tumours. EURADOS WG9 performed comparative measurements of scattered radiation in the Proteus C-235 IBA facility (Cyclotron Centre Bronowice at the Institute of Nuclear Physics, CCB IFJ PAN, Kraków, Poland) using two anthropomorphic phantoms-5 and 10 yr old-for a superficial target in the brain. Both active detectors located inside the therapy room, and passive detectors placed inside the phantoms were used. Measurements were supplemented by Monte Carlo simulation of the radiation transport. For the applied 3D printed pre-absorbers, out-of-field doses from both secondary photons and neutrons were lower than for RS. Measurements with active environmental dosimeters at five positions inside the therapy room indicated that the RS/BC ratio of the out-of-field dose was also higher than one, with a maximum of 1.7. Photon dose inside phantoms leads to higher out-of-field doses for RS than BC to almost all organs with the highest RS/BC ratio 12.5 and 13.2 for breasts for 5 and 10 yr old phantoms, respectively. For organs closest to the isocentre such as the thyroid, neutron doses were lower for BC than RS due to neutrons moderation in the target volume, but for more distant organs like bladder-conversely-lower doses for RS than BC were observed. The use of 3D printed BC as the pre-absorber placed in the near vicinity of patient in the treatment of superficial tumours does not result in the increase of secondary radiation compared to the treatment with RS, placed far from the patient.
- 650 _2
- $a nádory mozku $x radioterapie $7 D001932
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a metoda Monte Carlo $7 D009010
- 650 _2
- $a neutrony $7 D009502
- 650 _2
- $a fantomy radiodiagnostické $7 D019047
- 650 12
- $a 3D tisk $7 D066330
- 650 _2
- $a protonová terapie $x přístrojové vybavení $7 D061766
- 650 12
- $a dávka záření $7 D011829
- 650 _2
- $a celková dávka radioterapie $7 D011879
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Stolarczyk, L $u Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342, Poland $u Skandionkliniken, von Kraemers Allé 26, Uppsala 752 37, Sweden $u Dansk Center for Partikelterapi, Palle Juul-Jensens Boulevard 25, 8200 Aarhus N, Denmark
- 700 1_
- $a Ambrožová, I $u Department of Radiation Dosimetry, Nuclear Physics Institute Czech Academy of Sciences, Prague CZ-250 68 Řež, Czech Republic
- 700 1_
- $a Davídková, M $u Department of Radiation Dosimetry, Nuclear Physics Institute Czech Academy of Sciences, Prague CZ-250 68 Řež, Czech Republic
- 700 1_
- $a De Saint-Hubert, M $u Belgium Nuclear Research Centre (SCK CEN), Boeretang 200, Mol BE-2400, Belgium
- 700 1_
- $a Domański, S $u National Centre for Nuclear Research, Otwock-Świerk 05-400, Poland
- 700 1_
- $a Domingo, C $u Departament de Física, Universitat Autònoma de Barcelona (UAB), Bellaterra E-08193, Spain
- 700 1_
- $a Knežević, Ž $u Ruđer Bošković Institute, Bijenička c. 54, Zagreb 10000, Croatia
- 700 1_
- $a Kopeć, R $u Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342, Poland
- 700 1_
- $a Kuć, M $u National Centre for Nuclear Research, Otwock-Świerk 05-400, Poland
- 700 1_
- $a Majer, M $u Ruđer Bošković Institute, Bijenička c. 54, Zagreb 10000, Croatia
- 700 1_
- $a Mojżeszek, N $u Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342, Poland
- 700 1_
- $a Mares, V $u Helmholtz Zentrum München, Institute of Radiation Medicine, Ingolstädter Landstraße 1, Neuherberg 85764, Germany
- 700 1_
- $a Martínez-Rovira, I $u Departament de Física, Universitat Autònoma de Barcelona (UAB), Bellaterra E-08193, Spain
- 700 1_
- $a Caballero-Pacheco, M Á $u Departament de Física, Universitat Autònoma de Barcelona (UAB), Bellaterra E-08193, Spain
- 700 1_
- $a Pyszka, E $u Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342, Poland
- 700 1_
- $a Swakoń, J $u Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342, Poland
- 700 1_
- $a Trinkl, S $u Helmholtz Zentrum München, Institute of Radiation Medicine, Ingolstädter Landstraße 1, Neuherberg 85764, Germany $u Technische Universität München, Physik-Department, Garching 85748, Germany
- 700 1_
- $a Tisi, M $u Helmholtz Zentrum München, Institute of Radiation Medicine, Ingolstädter Landstraße 1, Neuherberg 85764, Germany
- 700 1_
- $a Harrison, R $u University of Newcastle upon Tyne, Tyne and Wear, Newcastle upon Tyne NE1 7RU, United Kingdom
- 700 1_
- $a Olko, P $u Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342, Poland
- 773 0_
- $w MED00003821 $t Physics in medicine and biology $x 1361-6560 $g Roč. 66, č. 3 (2021), s. 035012
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33202399 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100949 $b ABA008
- 999 __
- $a ok $b bmc $g 1690264 $s 1139850
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 66 $c 3 $d 035012 $e 20210126 $i 1361-6560 $m Physics in medicine and biology $n Phys Med Biol $x MED00003821
- LZP __
- $a Pubmed-20210728