Je něco špatně v tomto záznamu ?
Independent reaction times method in Geant4-DNA: Implementation and performance
J. Ramos-Méndez, WG. Shin, M. Karamitros, J. Domínguez-Kondo, NH. Tran, S. Incerti, C. Villagrasa, Y. Perrot, V. Štěpán, S. Okada, E. Moreno-Barbosa, B. Faddegon
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
Grantová podpora
R01 CA187003
NCI NIH HHS - United States
NIH R01 CA187003
UCSF Medical School Bridge
PubMed
32970844
DOI
10.1002/mp.14490
Knihovny.cz E-zdroje
- MeSH
- chemické modely * MeSH
- DNA MeSH
- lineární přenos energie * MeSH
- metoda Monte Carlo MeSH
- počítačová simulace MeSH
- reakční čas MeSH
- voda MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: The simulation of individual particle tracks and the chemical stage following water radiolysis in biological tissue is an effective means of improving our knowledge of the physico-chemical contribution to the biological effect of ionizing radiation. However, the step-by-step simulation of the reaction kinetics of radiolytic species is the most time-consuming task in Monte Carlo track-structure simulations, with long simulation times that are an impediment to research. In this work, we present the implementation of the independent reaction times (IRT) method in Geant4-DNA Monte Carlo toolkit to improve the computational efficiency of calculating G-values, defined as the number of chemical species created or lost per 100 eV of deposited energy. METHODS: The computational efficiency of IRT, as implemented, is compared to that from available Geant4-DNA step-by-step simulations for electrons, protons and alpha particles covering a wide range of linear energy transfer (LET). The accuracy of both methods is verified using published measured data from fast electron irradiations for • OH and eaq- for time-dependent G-values. For IRT, simulations in the presence of scavengers irradiated by cobalt-60 γ-ray and 2 MeV protons are compared with measured data for different scavenging capacities. In addition, a qualitative assessment comparing measured LET-dependent G-values with Geant4-DNA calculations in pure liquid water is presented. RESULTS: The IRT improved the computational efficiency by three orders of magnitude relative to the step-by-step method while differences in G-values by 3.9% at 1 μs were found. At 7 ps, • OH and eaq- yields calculated with IRT differed from recent published measured data by 5% ± 4% and 2% ± 4%, respectively. At 1 μs, differences were 9% ± 5% and 6% ± 7% for • OH and eaq- , respectively. Uncertainties are one standard deviation. Finally, G-values at different scavenging capacities and LET-dependent G-values reproduced the behavior of measurements for all radiation qualities. CONCLUSION: The comprehensive validation of the Geant4-DNA capabilities to accurately simulate the chemistry following water radiolysis is an ongoing work. The implementation presented in this work is a necessary step to facilitate performing such a task.
Department of Radiation Convergence Engineering Yonsei University Wonju 26493 Korea
Department of Radiation Dosimetry Nuclear Physics Institute of the CAS Prague Czech Republic
Department of Radiation Oncology University of California San Francisco San Francisco CA 94115 USA
Institut de Radioprotection et de Sûreté Nucléaire IRSN BP17 Fontenay aux Roses 92262 France
KEK 1 1 Oho Tsukuba Ibaraki 305 0801 Japan
Radiation Laboratory University of Notre Dame Notre Dame IN 46556 USA
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019922
- 003
- CZ-PrNML
- 005
- 20210830101531.0
- 007
- ta
- 008
- 210728s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/mp.14490 $2 doi
- 035 __
- $a (PubMed)32970844
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Ramos-Méndez, José $u Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, 94115, USA
- 245 10
- $a Independent reaction times method in Geant4-DNA: Implementation and performance / $c J. Ramos-Méndez, WG. Shin, M. Karamitros, J. Domínguez-Kondo, NH. Tran, S. Incerti, C. Villagrasa, Y. Perrot, V. Štěpán, S. Okada, E. Moreno-Barbosa, B. Faddegon
- 520 9_
- $a PURPOSE: The simulation of individual particle tracks and the chemical stage following water radiolysis in biological tissue is an effective means of improving our knowledge of the physico-chemical contribution to the biological effect of ionizing radiation. However, the step-by-step simulation of the reaction kinetics of radiolytic species is the most time-consuming task in Monte Carlo track-structure simulations, with long simulation times that are an impediment to research. In this work, we present the implementation of the independent reaction times (IRT) method in Geant4-DNA Monte Carlo toolkit to improve the computational efficiency of calculating G-values, defined as the number of chemical species created or lost per 100 eV of deposited energy. METHODS: The computational efficiency of IRT, as implemented, is compared to that from available Geant4-DNA step-by-step simulations for electrons, protons and alpha particles covering a wide range of linear energy transfer (LET). The accuracy of both methods is verified using published measured data from fast electron irradiations for • OH and eaq- for time-dependent G-values. For IRT, simulations in the presence of scavengers irradiated by cobalt-60 γ-ray and 2 MeV protons are compared with measured data for different scavenging capacities. In addition, a qualitative assessment comparing measured LET-dependent G-values with Geant4-DNA calculations in pure liquid water is presented. RESULTS: The IRT improved the computational efficiency by three orders of magnitude relative to the step-by-step method while differences in G-values by 3.9% at 1 μs were found. At 7 ps, • OH and eaq- yields calculated with IRT differed from recent published measured data by 5% ± 4% and 2% ± 4%, respectively. At 1 μs, differences were 9% ± 5% and 6% ± 7% for • OH and eaq- , respectively. Uncertainties are one standard deviation. Finally, G-values at different scavenging capacities and LET-dependent G-values reproduced the behavior of measurements for all radiation qualities. CONCLUSION: The comprehensive validation of the Geant4-DNA capabilities to accurately simulate the chemistry following water radiolysis is an ongoing work. The implementation presented in this work is a necessary step to facilitate performing such a task.
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a DNA $7 D004247
- 650 12
- $a lineární přenos energie $7 D018499
- 650 12
- $a chemické modely $7 D008956
- 650 _2
- $a metoda Monte Carlo $7 D009010
- 650 _2
- $a reakční čas $7 D011930
- 650 _2
- $a voda $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Shin, Wook-Geun $u Centre d'Études Nucléaires de Bordeaux Gradignan, Université de Bordeaux, CNRS/IN2P3, UMR5797, Gradignan, 33175, France $u Department of Radiation Convergence Engineering, Yonsei University, Wonju, 26493, Korea
- 700 1_
- $a Karamitros, Mathieu $u Radiation Laboratory, University of Notre Dame, Notre Dame, IN, 46556, USA
- 700 1_
- $a Domínguez-Kondo, Jorge $u Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Puebla PUE, 72000, Mexico
- 700 1_
- $a Tran, Ngoc Hoang $u Centre d'Études Nucléaires de Bordeaux Gradignan, Université de Bordeaux, CNRS/IN2P3, UMR5797, Gradignan, 33175, France
- 700 1_
- $a Incerti, Sebastien $u Centre d'Études Nucléaires de Bordeaux Gradignan, Université de Bordeaux, CNRS/IN2P3, UMR5797, Gradignan, 33175, France
- 700 1_
- $a Villagrasa, Carmen $u Institut de Radioprotection et de Sûreté Nucléaire, IRSN, BP17, Fontenay-aux-Roses, 92262, France
- 700 1_
- $a Perrot, Yann $u Institut de Radioprotection et de Sûreté Nucléaire, IRSN, BP17, Fontenay-aux-Roses, 92262, France
- 700 1_
- $a Štěpán, Václav $u Department of Radiation Dosimetry, Nuclear Physics Institute of the CAS, Prague, Czech Republic
- 700 1_
- $a Okada, Shogo $u KEK, 1-1, Oho, Tsukuba, Ibaraki, 305-0801, Japan
- 700 1_
- $a Moreno-Barbosa, Eduardo $u Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Puebla PUE, 72000, Mexico
- 700 1_
- $a Faddegon, Bruce $u Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, 94115, USA
- 773 0_
- $w MED00003245 $t Medical physics $x 2473-4209 $g Roč. 47, č. 11 (2020), s. 5919-5930
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32970844 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830101531 $b ABA008
- 999 __
- $a ok $b bmc $g 1690679 $s 1140368
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 47 $c 11 $d 5919-5930 $e 20201015 $i 2473-4209 $m Medical physics $n Med Phys $x MED00003245
- GRA __
- $a R01 CA187003 $p NCI NIH HHS $2 United States
- GRA __
- $a NIH R01 CA187003 $p UCSF Medical School Bridge
- LZP __
- $a Pubmed-20210728