Something wrong with this record ?
Photon-counting CT review
T. Flohr, M. Petersilka, A. Henning, S. Ulzheimer, J. Ferda, B. Schmidt
Language English Country Italy
Document type Journal Article, Review
- MeSH
- Photons * MeSH
- Tomography, X-Ray Computed * MeSH
- Publication type
- Journal Article MeSH
- Review MeSH
Photon-counting detectors are a promising new technology for computed tomography (CT) systems. They provide energy-resolved CT data at very high spatial resolution without electronic noise and with improved tissue contrasts. This review article gives an overview of the principles of photon-counting detector CT, of potential clinical benefits and limitations, and of the experience gained so far in pre-clinical installations.
Charles University Prague Medical Faculty Pilsen 304 60 Pilsen Czech Republic
Siemens Healthcare GmbH Computed Tomography 91301 Forchheim Germany
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019933
- 003
- CZ-PrNML
- 005
- 20210830101536.0
- 007
- ta
- 008
- 210728s2020 it f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ejmp.2020.10.030 $2 doi
- 035 __
- $a (PubMed)33249223
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a it
- 100 1_
- $a Flohr, Thomas $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany. Electronic address: thomas.flohr@siemens-healthineers.com
- 245 10
- $a Photon-counting CT review / $c T. Flohr, M. Petersilka, A. Henning, S. Ulzheimer, J. Ferda, B. Schmidt
- 520 9_
- $a Photon-counting detectors are a promising new technology for computed tomography (CT) systems. They provide energy-resolved CT data at very high spatial resolution without electronic noise and with improved tissue contrasts. This review article gives an overview of the principles of photon-counting detector CT, of potential clinical benefits and limitations, and of the experience gained so far in pre-clinical installations.
- 650 12
- $a fotony $7 D017785
- 650 12
- $a počítačová rentgenová tomografie $7 D014057
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Petersilka, Martin $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
- 700 1_
- $a Henning, Andre $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
- 700 1_
- $a Ulzheimer, Stefan $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
- 700 1_
- $a Ferda, Jiri $u Charles University Prague, Medical Faculty Pilsen, 304 60 Pilsen, Czech Republic
- 700 1_
- $a Schmidt, Bernhard $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
- 773 0_
- $w MED00167391 $t Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) $x 1724-191X $g Roč. 79, č. - (2020), s. 126-136
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33249223 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830101536 $b ABA008
- 999 __
- $a ok $b bmc $g 1690686 $s 1140379
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 79 $c - $d 126-136 $e 20201126 $i 1724-191X $m Physica medica $n Phys Med $x MED00167391
- LZP __
- $a Pubmed-20210728