Photon-counting CT review

T. Flohr, M. Petersilka, A. Henning, S. Ulzheimer, J. Ferda, B. Schmidt

. 2020 ; 79 (-) : 126-136. [pub] 20201126

Jazyk angličtina Země Itálie

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019933

Photon-counting detectors are a promising new technology for computed tomography (CT) systems. They provide energy-resolved CT data at very high spatial resolution without electronic noise and with improved tissue contrasts. This review article gives an overview of the principles of photon-counting detector CT, of potential clinical benefits and limitations, and of the experience gained so far in pre-clinical installations.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019933
003      
CZ-PrNML
005      
20210830101536.0
007      
ta
008      
210728s2020 it f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ejmp.2020.10.030 $2 doi
035    __
$a (PubMed)33249223
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a it
100    1_
$a Flohr, Thomas $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany. Electronic address: thomas.flohr@siemens-healthineers.com
245    10
$a Photon-counting CT review / $c T. Flohr, M. Petersilka, A. Henning, S. Ulzheimer, J. Ferda, B. Schmidt
520    9_
$a Photon-counting detectors are a promising new technology for computed tomography (CT) systems. They provide energy-resolved CT data at very high spatial resolution without electronic noise and with improved tissue contrasts. This review article gives an overview of the principles of photon-counting detector CT, of potential clinical benefits and limitations, and of the experience gained so far in pre-clinical installations.
650    12
$a fotony $7 D017785
650    12
$a počítačová rentgenová tomografie $7 D014057
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Petersilka, Martin $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
700    1_
$a Henning, Andre $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
700    1_
$a Ulzheimer, Stefan $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
700    1_
$a Ferda, Jiri $u Charles University Prague, Medical Faculty Pilsen, 304 60 Pilsen, Czech Republic
700    1_
$a Schmidt, Bernhard $u Siemens Healthcare GmbH, Computed Tomography, 91301 Forchheim, Germany
773    0_
$w MED00167391 $t Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) $x 1724-191X $g Roč. 79, č. - (2020), s. 126-136
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33249223 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830101536 $b ABA008
999    __
$a ok $b bmc $g 1690686 $s 1140379
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 79 $c - $d 126-136 $e 20201126 $i 1724-191X $m Physica medica $n Phys Med $x MED00167391
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...