Something wrong with this record ?
Tibio-femoral kinematics of the healthy knee joint throughout complete cycles of gait activities
B. Postolka, P. Schütz, SF. Fucentese, MAR. Freeman, V. Pinskerova, R. List, WR. Taylor
Language English Country United States
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
ProQuest Central
from 2003-01-01 to 2 months ago
Health & Medicine (ProQuest)
from 2003-01-01 to 2 months ago
- MeSH
- Biomechanical Phenomena MeSH
- Gait MeSH
- Femur * diagnostic imaging MeSH
- Knee Joint * MeSH
- Humans MeSH
- Range of Motion, Articular MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Accurate assessment of 3D tibio-femoral kinematics is essential for understanding knee joint functionality, but also provides a basis for assessing joint pathologies and the efficacy of musculoskeletal interventions. Until now, however, the assessment of functional kinematics in healthy knees has been mostly restricted to the loaded stance phase of gait, and level walking only, but the most critical conditions for the surrounding soft tissues are known to occur during high-flexion activities. This study aimed to determine the ranges of tibio-femoral rotation and condylar translation as well as provide evidence on the location of the centre of rotation during multiple complete cycles of different gait activities. Based on radiographic images captured using moving fluoroscopy in ten healthy subjects during multiple cycles of level walking, downhill walking and stair descent, 3D femoral and tibial poses were reconstructed to provide a comprehensive description of tibio-femoral kinematics. Despite a significant increase in joint flexion, the condylar antero-posterior range of motion remained comparable across all activities, with mean translations of 6.3-8.3 mm and 7.3-9.3 mm for the medial and lateral condyles respectively. Only the swing phase of level walking and stair descent exhibited a significantly greater range of motion for the lateral over the medial compartment. Although intra-subject variability was low, considerable differences in joint kinematics were observed between subjects. The observed subject-specific movement patterns indicate that accurate assessment of individual pre-operative kinematics together with individual implant selection and/or surgical implantation decisions might be necessary before further improvement to joint replacement outcome can be achieved.
Balgrist University Hospital Zürich Switzerland
Human Performance Lab Schulthess Clinic Zürich Switzerland
Institute for Biomechanics ETH Zürich Zürich Switzerland
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21020114
- 003
- CZ-PrNML
- 005
- 20210830101727.0
- 007
- ta
- 008
- 210728s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jbiomech.2020.109915 $2 doi
- 035 __
- $a (PubMed)32827791
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Postolka, Barbara $u Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- 245 10
- $a Tibio-femoral kinematics of the healthy knee joint throughout complete cycles of gait activities / $c B. Postolka, P. Schütz, SF. Fucentese, MAR. Freeman, V. Pinskerova, R. List, WR. Taylor
- 520 9_
- $a Accurate assessment of 3D tibio-femoral kinematics is essential for understanding knee joint functionality, but also provides a basis for assessing joint pathologies and the efficacy of musculoskeletal interventions. Until now, however, the assessment of functional kinematics in healthy knees has been mostly restricted to the loaded stance phase of gait, and level walking only, but the most critical conditions for the surrounding soft tissues are known to occur during high-flexion activities. This study aimed to determine the ranges of tibio-femoral rotation and condylar translation as well as provide evidence on the location of the centre of rotation during multiple complete cycles of different gait activities. Based on radiographic images captured using moving fluoroscopy in ten healthy subjects during multiple cycles of level walking, downhill walking and stair descent, 3D femoral and tibial poses were reconstructed to provide a comprehensive description of tibio-femoral kinematics. Despite a significant increase in joint flexion, the condylar antero-posterior range of motion remained comparable across all activities, with mean translations of 6.3-8.3 mm and 7.3-9.3 mm for the medial and lateral condyles respectively. Only the swing phase of level walking and stair descent exhibited a significantly greater range of motion for the lateral over the medial compartment. Although intra-subject variability was low, considerable differences in joint kinematics were observed between subjects. The observed subject-specific movement patterns indicate that accurate assessment of individual pre-operative kinematics together with individual implant selection and/or surgical implantation decisions might be necessary before further improvement to joint replacement outcome can be achieved.
- 650 _2
- $a biomechanika $7 D001696
- 650 12
- $a femur $x diagnostické zobrazování $7 D005269
- 650 _2
- $a chůze (způsob) $7 D005684
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a kolenní kloub $7 D007719
- 650 _2
- $a rozsah kloubních pohybů $7 D016059
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Schütz, Pascal $u Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- 700 1_
- $a Fucentese, Sandro F $u Balgrist University Hospital, Zürich, Switzerland
- 700 1_
- $a Freeman, Michael A R $u Royal London Hospital, London, United Kingdom
- 700 1_
- $a Pinskerova, Vera $u Medical Faculty, Charles University, Prague, Czech Republic
- 700 1_
- $a List, Renate $u Institute for Biomechanics, ETH Zürich, Zürich, Switzerland; Human Performance Lab, Schulthess Clinic, Zürich, Switzerland
- 700 1_
- $a Taylor, William R $u Institute for Biomechanics, ETH Zürich, Zürich, Switzerland. Electronic address: bt@ethz.ch
- 773 0_
- $w MED00002553 $t Journal of biomechanics $x 1873-2380 $g Roč. 110, č. - (2020), s. 109915
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32827791 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830101727 $b ABA008
- 999 __
- $a ok $b bmc $g 1690825 $s 1140560
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 110 $c - $d 109915 $e 20200718 $i 1873-2380 $m Journal of biomechanics $n J Biomech $x MED00002553
- LZP __
- $a Pubmed-20210728