-
Je něco špatně v tomto záznamu ?
Thresholds for oximetry alarms and target range in the NICU: an observational assessment based on likely oxygen tension and maturity
TE. Bachman, NP. Iyer, CJL. Newth, PA. Ross, RG. Khemani
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, pozorovací studie
NLK
BioMedCentral
od 2001-12-01
BioMedCentral Open Access
od 2001
Directory of Open Access Journals
od 2001
Free Medical Journals
od 2001
PubMed Central
od 2001
Europe PubMed Central
od 2001
ProQuest Central
od 2009-01-01
Open Access Digital Library
od 2001-02-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Medline Complete (EBSCOhost)
od 2001-01-01
Health & Medicine (ProQuest)
od 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
Springer Nature OA/Free Journals
od 2001-12-01
- MeSH
- analýza krevních plynů MeSH
- hypoxie diagnóza etiologie MeSH
- jednotky intenzivní péče o novorozence * MeSH
- kojenec MeSH
- kyslík * MeSH
- lidé MeSH
- novorozenec MeSH
- oxymetrie MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
BACKGROUND: Continuous monitoring of SpO2 in the neonatal ICU is the standard of care. Changes in SpO2 exposure have been shown to markedly impact outcome, but limiting extreme episodes is an arduous task. Much more complicated than setting alarm policy, it is fraught with balancing alarm fatigue and compliance. Information on optimum strategies is limited. METHODS: This is a retrospective observational study intended to describe the relative chance of normoxemia, and risks of hypoxemia and hyperoxemia at relevant SpO2 levels in the neonatal ICU. The data, paired SpO2-PaO2 and post-menstrual age, are from a single tertiary care unit. They reflect all infants receiving supplemental oxygen and mechanical ventilation during a 3-year period. The primary measures were the chance of normoxemia (PaO2 50-80 mmHg), risks of severe hypoxemia (PaO2 ≤ 40 mmHg), and of severe hyperoxemia (PaO2 ≥ 100 mmHg) at relevant SpO2 levels. RESULTS: Neonates were categorized by postmenstrual age: < 33 (n = 155), 33-36 (n = 192) and > 36 (n = 1031) weeks. From these infants, 26,162 SpO2-PaO2 pairs were evaluated. The post-menstrual weeks (median and IQR) of the three groups were: 26 (24-28) n = 2603; 34 (33-35) n = 2501; and 38 (37-39) n = 21,058. The chance of normoxemia (65, 95%-CI 64-67%) was similar across the SpO2 range of 88-95%, and independent of PMA. The increasing risk of severe hypoxemia became marked at a SpO2 of 85% (25, 95%-CI 21-29%), and was independent of PMA. The risk of severe hyperoxemia was dependent on PMA. For infants < 33 weeks it was marked at 98% SpO2 (25, 95%-CI 18-33%), for infants 33-36 weeks at 97% SpO2 (24, 95%-CI 14-25%) and for those > 36 weeks at 96% SpO2 (20, 95%-CI 17-22%). CONCLUSIONS: The risk of hyperoxemia and hypoxemia increases exponentially as SpO2 moves towards extremes. Postmenstrual age influences the threshold at which the risk of hyperoxemia became pronounced, but not the thresholds of hypoxemia or normoxemia. The thresholds at which a marked change in the risk of hyperoxemia and hypoxemia occur can be used to guide the setting of alarm thresholds. Optimal management of neonatal oxygen saturation must take into account concerns of alarm fatigue, staffing levels, and FiO2 titration practices.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21020434
- 003
- CZ-PrNML
- 005
- 20210830102124.0
- 007
- ta
- 008
- 210728s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s12887-020-02225-3 $2 doi
- 035 __
- $a (PubMed)32593300
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Bachman, Thomas E $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic. TBachman@ME.com $u , Lake Arrowhead, USA. TBachman@ME.com
- 245 10
- $a Thresholds for oximetry alarms and target range in the NICU: an observational assessment based on likely oxygen tension and maturity / $c TE. Bachman, NP. Iyer, CJL. Newth, PA. Ross, RG. Khemani
- 520 9_
- $a BACKGROUND: Continuous monitoring of SpO2 in the neonatal ICU is the standard of care. Changes in SpO2 exposure have been shown to markedly impact outcome, but limiting extreme episodes is an arduous task. Much more complicated than setting alarm policy, it is fraught with balancing alarm fatigue and compliance. Information on optimum strategies is limited. METHODS: This is a retrospective observational study intended to describe the relative chance of normoxemia, and risks of hypoxemia and hyperoxemia at relevant SpO2 levels in the neonatal ICU. The data, paired SpO2-PaO2 and post-menstrual age, are from a single tertiary care unit. They reflect all infants receiving supplemental oxygen and mechanical ventilation during a 3-year period. The primary measures were the chance of normoxemia (PaO2 50-80 mmHg), risks of severe hypoxemia (PaO2 ≤ 40 mmHg), and of severe hyperoxemia (PaO2 ≥ 100 mmHg) at relevant SpO2 levels. RESULTS: Neonates were categorized by postmenstrual age: < 33 (n = 155), 33-36 (n = 192) and > 36 (n = 1031) weeks. From these infants, 26,162 SpO2-PaO2 pairs were evaluated. The post-menstrual weeks (median and IQR) of the three groups were: 26 (24-28) n = 2603; 34 (33-35) n = 2501; and 38 (37-39) n = 21,058. The chance of normoxemia (65, 95%-CI 64-67%) was similar across the SpO2 range of 88-95%, and independent of PMA. The increasing risk of severe hypoxemia became marked at a SpO2 of 85% (25, 95%-CI 21-29%), and was independent of PMA. The risk of severe hyperoxemia was dependent on PMA. For infants < 33 weeks it was marked at 98% SpO2 (25, 95%-CI 18-33%), for infants 33-36 weeks at 97% SpO2 (24, 95%-CI 14-25%) and for those > 36 weeks at 96% SpO2 (20, 95%-CI 17-22%). CONCLUSIONS: The risk of hyperoxemia and hypoxemia increases exponentially as SpO2 moves towards extremes. Postmenstrual age influences the threshold at which the risk of hyperoxemia became pronounced, but not the thresholds of hypoxemia or normoxemia. The thresholds at which a marked change in the risk of hyperoxemia and hypoxemia occur can be used to guide the setting of alarm thresholds. Optimal management of neonatal oxygen saturation must take into account concerns of alarm fatigue, staffing levels, and FiO2 titration practices.
- 650 _2
- $a analýza krevních plynů $7 D001784
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hypoxie $x diagnóza $x etiologie $7 D000860
- 650 _2
- $a kojenec $7 D007223
- 650 _2
- $a novorozenec $7 D007231
- 650 12
- $a jednotky intenzivní péče o novorozence $7 D007363
- 650 _2
- $a oxymetrie $7 D010092
- 650 12
- $a kyslík $7 D010100
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a pozorovací studie $7 D064888
- 700 1_
- $a Iyer, Narayan P $u Fetal and Neonatal Institute, Children's Hospital Los Angeles, University of Southern California Keck School of Medicine, Los Angeles, CA, USA
- 700 1_
- $a Newth, Christopher J L $u Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, University of Southern California Keck School of Medicine, Los Angeles, CA, USA
- 700 1_
- $a Ross, Patrick A $u Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, University of Southern California Keck School of Medicine, Los Angeles, CA, USA
- 700 1_
- $a Khemani, Robinder G $u Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, University of Southern California Keck School of Medicine, Los Angeles, CA, USA
- 773 0_
- $w MED00008201 $t BMC pediatrics $x 1471-2431 $g Roč. 20, č. 1 (2020), s. 317
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32593300 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830102124 $b ABA008
- 999 __
- $a ok $b bmc $g 1691080 $s 1140880
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 20 $c 1 $d 317 $e 20200627 $i 1471-2431 $m BMC pediatrics $n BMC Pediatr $x MED00008201
- LZP __
- $a Pubmed-20210728