Cement augmentation of odontoid peg fractures: the effect of cement volume and distribution on construct stiffness

L. Capek, P. Rehousek, P. Henys, S. Bleibleh, E. Jenner, M. Kulvajtova, J. Skala-Rosenbaum

. 2020 ; 29 (5) : 977-985. [pub] 20200104

Language English Country Germany

Document type Journal Article, Research Support, Non-U.S. Gov't

Grant support
816016 Charles University Grant Agency - International

E-resources Online Full text

NLK ProQuest Central from 1997-01-01 to 1 year ago
Medline Complete (EBSCOhost) from 2000-02-01 to 1 year ago
Health & Medicine (ProQuest) from 1997-01-01 to 1 year ago

PURPOSE: The cement augmentation of a conventional anterior screw fixation in type II odontoid process fractures for elderly patients significantly increased stiffness and load to failure under anterior-posterior load in comparison with non-augmented fixation. The amount and quality of bone cement are usually taken ad hoc in clinical practise. In this study, we wanted to clarify the role of bone cement amount and its quality to the stiffness of odontoid and vertebrae body junction. METHODS: Finite-element method was used to achieve different scenarios of cement augmentation. For all models, an initial stiffness was calculated. Model (1) the intact vertebrae were virtually potted into a polymethylmethacrylate base via the posterior vertebral arches. A V-shaped punch was used for loading the odontoid in an anterior-posterior direction. (2) The odontoid fracture type IIa (Anderson-D'Alonzo classification) was achieved by virtual transverse osteotomy. Anterior screw fixation was virtually performed by putting self-drilling titanium alloy 3.5 mm diameter anterior cannulated lag screw with a 12 mm thread into the inspected vertebrae. A V-shaped punch was used for loading the odontoid in an anterior-posterior direction. The vertebrae body was assumed to be non-cemented and cemented with different volume. RESULTS: The mean cement volume was lowest for body base filling with 0.47 ± 0.03 ml. The standard body filling corresponds to 0.95 ± 0.15 ml. The largest volume corresponds to 1.62 ± 0.12 ml in the presence of cement leakage. The initial stiffness of the intact C2 vertebrae was taken as the reference value. The mean initial stiffness for non-porous cement (E = 3000 MPa) increased linearly (R2 = 0.98). The lowest stiffness (123.3 ± 5.8 N/mm) was measured in the intact C2 vertebrae. However, the highest stiffness (165.2 ± 5.2 N/mm) was measured when cement leakage out of the odontoid peg occurred. The mean initial stiffness of the base-only cemented group was 147.2 ± 8.4 N/mm compared with 157.9 ± 6.6 N/mm for the base and body cemented group. This difference was statistically significant (p < 0.0061). The mean initial stiffness for porous cement (E = 500 MPa) remains constant. Therefore, there is no difference between cemented and non-cemented junction. This difference was not statistically significant (p < 0.18). CONCLUSION: The present study showed that the low porous cement was able to significantly influence the stiffness of the augmented odontoid screw fixation in vitro, although further in vivo clinical studies should be undertaken. Our results suggest that only a small amount of non-porous cement is needed to restore stiffness at least to its pre-fracture level and this can be achieved with the injection of 0.7-1.2 ml of cement. These slides can be retrieved under Electronic Supplementary Material.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21020572
003      
CZ-PrNML
005      
20210830102221.0
007      
ta
008      
210728s2020 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00586-019-06286-6 $2 doi
035    __
$a (PubMed)31902000
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Capek, Lukas $u Technical University of Liberec, Studentska 1402/2, 461 17, Liberec, Czechia
245    10
$a Cement augmentation of odontoid peg fractures: the effect of cement volume and distribution on construct stiffness / $c L. Capek, P. Rehousek, P. Henys, S. Bleibleh, E. Jenner, M. Kulvajtova, J. Skala-Rosenbaum
520    9_
$a PURPOSE: The cement augmentation of a conventional anterior screw fixation in type II odontoid process fractures for elderly patients significantly increased stiffness and load to failure under anterior-posterior load in comparison with non-augmented fixation. The amount and quality of bone cement are usually taken ad hoc in clinical practise. In this study, we wanted to clarify the role of bone cement amount and its quality to the stiffness of odontoid and vertebrae body junction. METHODS: Finite-element method was used to achieve different scenarios of cement augmentation. For all models, an initial stiffness was calculated. Model (1) the intact vertebrae were virtually potted into a polymethylmethacrylate base via the posterior vertebral arches. A V-shaped punch was used for loading the odontoid in an anterior-posterior direction. (2) The odontoid fracture type IIa (Anderson-D'Alonzo classification) was achieved by virtual transverse osteotomy. Anterior screw fixation was virtually performed by putting self-drilling titanium alloy 3.5 mm diameter anterior cannulated lag screw with a 12 mm thread into the inspected vertebrae. A V-shaped punch was used for loading the odontoid in an anterior-posterior direction. The vertebrae body was assumed to be non-cemented and cemented with different volume. RESULTS: The mean cement volume was lowest for body base filling with 0.47 ± 0.03 ml. The standard body filling corresponds to 0.95 ± 0.15 ml. The largest volume corresponds to 1.62 ± 0.12 ml in the presence of cement leakage. The initial stiffness of the intact C2 vertebrae was taken as the reference value. The mean initial stiffness for non-porous cement (E = 3000 MPa) increased linearly (R2 = 0.98). The lowest stiffness (123.3 ± 5.8 N/mm) was measured in the intact C2 vertebrae. However, the highest stiffness (165.2 ± 5.2 N/mm) was measured when cement leakage out of the odontoid peg occurred. The mean initial stiffness of the base-only cemented group was 147.2 ± 8.4 N/mm compared with 157.9 ± 6.6 N/mm for the base and body cemented group. This difference was statistically significant (p < 0.0061). The mean initial stiffness for porous cement (E = 500 MPa) remains constant. Therefore, there is no difference between cemented and non-cemented junction. This difference was not statistically significant (p < 0.18). CONCLUSION: The present study showed that the low porous cement was able to significantly influence the stiffness of the augmented odontoid screw fixation in vitro, although further in vivo clinical studies should be undertaken. Our results suggest that only a small amount of non-porous cement is needed to restore stiffness at least to its pre-fracture level and this can be achieved with the injection of 0.7-1.2 ml of cement. These slides can be retrieved under Electronic Supplementary Material.
650    _2
$a senioři $7 D000368
650    _2
$a kostní cementy $x terapeutické užití $7 D001843
650    _2
$a kostní šrouby $7 D001863
650    _2
$a vnitřní fixace fraktury $7 D005593
650    _2
$a lidé $7 D006801
650    12
$a dens axis $x diagnostické zobrazování $x zranění $x chirurgie $7 D009809
650    12
$a fraktury páteře $x diagnostické zobrazování $x chirurgie $7 D016103
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Rehousek, Petr $u Royal Orthopaedic Hospital, Bristol Rd South, Birmingham, B32 1AP, UK $u Third Faculty of Medicine, Charles University, Prague, Ruska 2411/87, 100 00, Praha 10, Vinohrady, Czechia
700    1_
$a Henys, Petr $u Technical University of Liberec, Studentska 1402/2, 461 17, Liberec, Czechia. petr.henys@tul.cz
700    1_
$a Bleibleh, Sabri $u Royal Orthopaedic Hospital, Bristol Rd South, Birmingham, B32 1AP, UK
700    1_
$a Jenner, Edward $u Royal Orthopaedic Hospital, Bristol Rd South, Birmingham, B32 1AP, UK
700    1_
$a Kulvajtova, Marketa $u Third Faculty of Medicine, Charles University, Prague, Ruska 2411/87, 100 00, Praha 10, Vinohrady, Czechia
700    1_
$a Skala-Rosenbaum, Jiri $u Third Faculty of Medicine, Charles University, Prague, Ruska 2411/87, 100 00, Praha 10, Vinohrady, Czechia
773    0_
$w MED00001666 $t European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society $x 1432-0932 $g Roč. 29, č. 5 (2020), s. 977-985
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31902000 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830102222 $b ABA008
999    __
$a ok $b bmc $g 1691196 $s 1141018
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 29 $c 5 $d 977-985 $e 20200104 $i 1432-0932 $m European spine journal $n Eur Spine J $x MED00001666
GRA    __
$a 816016 $p Charles University Grant Agency $2 International
LZP    __
$a Pubmed-20210728

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...