Je něco špatně v tomto záznamu ?
Temporal Visual Field Border
J. Lestak, T. Lestak, M. Fus, I. Klimesova
Jazyk angličtina Země Nový Zéland
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2007
Free Medical Journals
od 2007
Freely Accessible Science Journals
od 2007
PubMed Central
od 2007
Europe PubMed Central
od 2007
ProQuest Central
od 2007-01-01
Open Access Digital Library
od 2007-01-01
Open Access Digital Library
od 2007-01-01
Taylor & Francis Open Access
od 2007-12-01
Health & Medicine (ProQuest)
od 2007-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2007
PubMed
34376968
DOI
10.2147/opth.s321110
Knihovny.cz E-zdroje
- Publikační typ
- časopisecké články MeSH
Purpose: The aim of the study was to determine the physiological temporal visual field border, based on theoretical calculations and by perimetric examination itself. Materials and Methods: A perimetry test was performed on 15 healthy subjects - seven women (27-30 years old) and eight men (28-46 years old), all of whom had healthy eyes with a visual acuity value of 1.0. The visual field was evaluated using a Medmont M700 with nasal displacement of the fixation point of 40 degrees. In total, 179 examined points of visual field were included. The model of the entry of temporal rays into the eye was created on the basis of the measured biometric values of the eye and with the help of the AD systems AutoCad and SolidWorks. RayViz for SolidWorks was able to simulate the passage of light rays through the model. Results: The temporal part of the subjective visual field border was up to 110 degrees in all eyes. Modelling of the input rays based on geometric optics in one of the participants in the testing revealed a theoretical temporal boundary of the visual field of 102 degrees. Conclusion: Theoretical calculations of geometric optics have shown that the temporal boundary of the visual field reaches up to 102 degrees in a healthy individual. By perimetric examination, this limit reached 110 degrees.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21024229
- 003
- CZ-PrNML
- 005
- 20211013134017.0
- 007
- ta
- 008
- 211006s2021 nz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.2147/OPTH.S321110 $2 doi
- 035 __
- $a (PubMed)34376968
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a nz
- 100 1_
- $a Lestak, Jan $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic
- 245 10
- $a Temporal Visual Field Border / $c J. Lestak, T. Lestak, M. Fus, I. Klimesova
- 520 9_
- $a Purpose: The aim of the study was to determine the physiological temporal visual field border, based on theoretical calculations and by perimetric examination itself. Materials and Methods: A perimetry test was performed on 15 healthy subjects - seven women (27-30 years old) and eight men (28-46 years old), all of whom had healthy eyes with a visual acuity value of 1.0. The visual field was evaluated using a Medmont M700 with nasal displacement of the fixation point of 40 degrees. In total, 179 examined points of visual field were included. The model of the entry of temporal rays into the eye was created on the basis of the measured biometric values of the eye and with the help of the AD systems AutoCad and SolidWorks. RayViz for SolidWorks was able to simulate the passage of light rays through the model. Results: The temporal part of the subjective visual field border was up to 110 degrees in all eyes. Modelling of the input rays based on geometric optics in one of the participants in the testing revealed a theoretical temporal boundary of the visual field of 102 degrees. Conclusion: Theoretical calculations of geometric optics have shown that the temporal boundary of the visual field reaches up to 102 degrees in a healthy individual. By perimetric examination, this limit reached 110 degrees.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Lestak, Tomas $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic
- 700 1_
- $a Fus, Martin $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic
- 700 1_
- $a Klimesova, Iva $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic
- 773 0_
- $w MED00165196 $t Clinical ophthalmology (Auckland, N.Z.) $x 1177-5467 $g Roč. 15, č. - (2021), s. 3241-3246
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34376968 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20211006 $b ABA008
- 991 __
- $a 20211013134014 $b ABA008
- 999 __
- $a ind $b bmc $g 1708242 $s 1144726
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 15 $c - $d 3241-3246 $e 20210803 $i 1177-5467 $m Clinical ophthalmology $n Clin Ophthalmol $x MED00165196
- LZP __
- $a Pubmed-20211006