Application of mechanical trigger for unobtrusive detection of respiratory disorders from body recoil micro-movements
D. Cimr, F. Studnicka, H. Fujita, R. Cimler, J. Slegr
Jazyk angličtina Země Irsko
Typ dokumentu časopisecké články
- MeSH
- algoritmy MeSH
- elektrokardiografie * MeSH
- lidé MeSH
- nemoci dýchací soustavy * MeSH
- neuronové sítě (počítačové) MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Background and Objectives Automatic detection of breathing disorders plays an important role in the early signalization of respiratory diseases. Measuring methods can be based on electrocardiogram (ECG), sound, oximetry, or respiratory analysis. However, these approaches require devices placed on the human body or they are prone to disturbance by environmental influences. To solve these problems, we proposed a heart contraction mechanical trigger for unobtrusive detection of respiratory disorders from the mechanical measurement of cardiac contractions. We designed a novel method to calculate this mechanical trigger purely from measured mechanical signals without the use of ECG. Methods The approach is a built-on calculation of the so-called euclidean arc length from the signals. In comparison to previous researches, this system does not require any equipment attached to a person. This is achieved by locating the tensometers on the bed. Data from sensors are fused by the Cartan curvatures method to beat-to-beat vector input for the Convolutional neural network (CNN) classifier. Results In sum, 2281 disordered and 5130 normal breathing samples was collected for analysis. The experiments with use of 10-fold cross validation show that accuracy, sensitivity, and specificity reach values of 96.37%, 92.46%, and 98.11% respectively. Conclusions By the approach for detection, the system offers a novel way for a completely unobtrusive diagnosis of breathing-related health problems. The proposed solution can effectively be deployed in all clinical or home environments.
Faculty of Information Technology Ho Chi Minh City University of Technology Ho Chi Minh City Vietnam
Faculty of Science University of Hradec Kralove Rokitanskeho 62 Hradec Kralove 50003 Czech Republic
Regional Research Center Iwate Prefectural University Iwate Japan
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21025195
- 003
- CZ-PrNML
- 005
- 20211026134033.0
- 007
- ta
- 008
- 211013s2021 ie f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.cmpb.2021.106149 $2 doi
- 035 __
- $a (PubMed)34015736
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ie
- 100 1_
- $a Cimr, Dalibor $u Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, Hradec Kralove 50003, Czech Republic
- 245 10
- $a Application of mechanical trigger for unobtrusive detection of respiratory disorders from body recoil micro-movements / $c D. Cimr, F. Studnicka, H. Fujita, R. Cimler, J. Slegr
- 520 9_
- $a Background and Objectives Automatic detection of breathing disorders plays an important role in the early signalization of respiratory diseases. Measuring methods can be based on electrocardiogram (ECG), sound, oximetry, or respiratory analysis. However, these approaches require devices placed on the human body or they are prone to disturbance by environmental influences. To solve these problems, we proposed a heart contraction mechanical trigger for unobtrusive detection of respiratory disorders from the mechanical measurement of cardiac contractions. We designed a novel method to calculate this mechanical trigger purely from measured mechanical signals without the use of ECG. Methods The approach is a built-on calculation of the so-called euclidean arc length from the signals. In comparison to previous researches, this system does not require any equipment attached to a person. This is achieved by locating the tensometers on the bed. Data from sensors are fused by the Cartan curvatures method to beat-to-beat vector input for the Convolutional neural network (CNN) classifier. Results In sum, 2281 disordered and 5130 normal breathing samples was collected for analysis. The experiments with use of 10-fold cross validation show that accuracy, sensitivity, and specificity reach values of 96.37%, 92.46%, and 98.11% respectively. Conclusions By the approach for detection, the system offers a novel way for a completely unobtrusive diagnosis of breathing-related health problems. The proposed solution can effectively be deployed in all clinical or home environments.
- 650 _2
- $a algoritmy $7 D000465
- 650 12
- $a elektrokardiografie $7 D004562
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a neuronové sítě (počítačové) $7 D016571
- 650 12
- $a nemoci dýchací soustavy $7 D012140
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Studnicka, Filip $u Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, Hradec Kralove 50003, Czech Republic
- 700 1_
- $a Fujita, Hamido $u Faculty of Information Technology, Ho Chi Minh City University of Technology (HUTECH), Ho Chi Minh City, Vietnam; DaSCI Andalusian Institute of Data Science and Computational Intelligence, University of Granada, Granada, Spain; Regional Research Center, Iwate Prefectural University, Iwate, Japan. Electronic address: h.fujita@hutech.edu.vn
- 700 1_
- $a Cimler, Richard $u Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, Hradec Kralove 50003, Czech Republic
- 700 1_
- $a Slegr, Jan $u Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, Hradec Kralove 50003, Czech Republic
- 773 0_
- $w MED00001214 $t Computer methods and programs in biomedicine $x 1872-7565 $g Roč. 207, č. - (2021), s. 106149
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34015736 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20211013 $b ABA008
- 991 __
- $a 20211026134039 $b ABA008
- 999 __
- $a ok $b bmc $g 1714308 $s 1145702
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 207 $c - $d 106149 $e 20210506 $i 1872-7565 $m Computer methods and programs in biomedicine $n Comput Methods Programs Biomed $x MED00001214
- LZP __
- $a Pubmed-20211013