Something wrong with this record ?
Divergent estimates of the ratio between Na+-Ca2+ current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes
M. Pásek, J. Šimurda, M. Bébarová, G. Christé
Language English Country Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Free Medical Journals
from 1966 to 6 months ago
Open Access Digital Library
from 1853-01-01
Open Access Digital Library
from 1853-01-01
PubMed
34313306
DOI
10.1242/jcs.258228
Knihovny.cz E-resources
- MeSH
- Myocytes, Cardiac * metabolism MeSH
- Rats MeSH
- Sodium-Calcium Exchanger MeSH
- Sarcolemma metabolism MeSH
- Sodium metabolism MeSH
- Heart Ventricles metabolism MeSH
- Calcium * metabolism MeSH
- Animals MeSH
- Check Tag
- Rats MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The ratio between Na+-Ca2+ exchange current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes (JNaCa-ratio) estimated from electrophysiological data published to date yields strikingly different values between 1.7 and nearly 40. Possible reasons for such divergence were analysed by Monte Carlo simulations assuming both normal and log-normal distribution of the measured data. The confidence intervals CI95 of the mean JNaCa-ratios computed from the reported data showed an overlap of values between 1 and 3, and between 0.3 and 4.3 in the case of normal and log-normal distribution, respectively. Further analyses revealed that the published high values likely result from a large scatter of data due to transmural differences in JNaCa, dispersion of cell membrane capacitances and variability in incomplete detubulation. Taking into account the asymmetric distribution of the measured data, the reduction of mean current densities after detubulation and the substantially smaller CI95 of lower values of the mean JNaCa-ratio, the values between 1.6 and 3.2 may be considered as the most accurate estimates. This implies that 40 to 60% of Na+-Ca2+ exchanger is located at the t-tubular membrane of adult rat ventricular cardiomyocytes.
Institute of Thermomechanics Czech Academy of Science Dolejškova 5 182 00 Prague Czech Republic
Laboratoire de Neurocardiologie EA4612 Université Lyon 1 Lyon F 69003 France
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21025350
- 003
- CZ-PrNML
- 005
- 20211026133910.0
- 007
- ta
- 008
- 211013s2021 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1242/jcs.258228 $2 doi
- 035 __
- $a (PubMed)34313306
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Pásek, Michal $u Institute of Thermomechanics, Czech Academy of Science, Dolejškova 5, 182 00, Prague, Czech Republic $u Department of Physiology, Faculty of Medicine, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- 245 10
- $a Divergent estimates of the ratio between Na+-Ca2+ current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes / $c M. Pásek, J. Šimurda, M. Bébarová, G. Christé
- 520 9_
- $a The ratio between Na+-Ca2+ exchange current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes (JNaCa-ratio) estimated from electrophysiological data published to date yields strikingly different values between 1.7 and nearly 40. Possible reasons for such divergence were analysed by Monte Carlo simulations assuming both normal and log-normal distribution of the measured data. The confidence intervals CI95 of the mean JNaCa-ratios computed from the reported data showed an overlap of values between 1 and 3, and between 0.3 and 4.3 in the case of normal and log-normal distribution, respectively. Further analyses revealed that the published high values likely result from a large scatter of data due to transmural differences in JNaCa, dispersion of cell membrane capacitances and variability in incomplete detubulation. Taking into account the asymmetric distribution of the measured data, the reduction of mean current densities after detubulation and the substantially smaller CI95 of lower values of the mean JNaCa-ratio, the values between 1.6 and 3.2 may be considered as the most accurate estimates. This implies that 40 to 60% of Na+-Ca2+ exchanger is located at the t-tubular membrane of adult rat ventricular cardiomyocytes.
- 650 _2
- $a zvířata $7 D000818
- 650 12
- $a vápník $x metabolismus $7 D002118
- 650 _2
- $a srdeční komory $x metabolismus $7 D006352
- 650 12
- $a kardiomyocyty $x metabolismus $7 D032383
- 650 _2
- $a krysa rodu Rattus $7 D051381
- 650 _2
- $a sarkolema $x metabolismus $7 D012508
- 650 _2
- $a sodík $x metabolismus $7 D012964
- 650 _2
- $a pumpa pro výměnu sodíku a vápníku $7 D019831
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šimurda, Jiří $u Department of Physiology, Faculty of Medicine, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- 700 1_
- $a Bébarová, Markéta $u Department of Physiology, Faculty of Medicine, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- 700 1_
- $a Christé, Georges $u Laboratoire de Neurocardiologie, EA4612, Université Lyon 1, Lyon F-69003, France
- 773 0_
- $w MED00002576 $t Journal of cell science $x 1477-9137 $g Roč. 134, č. 14 (2021)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34313306 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20211013 $b ABA008
- 991 __
- $a 20211026133916 $b ABA008
- 999 __
- $a ok $b bmc $g 1714409 $s 1145857
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 134 $c 14 $e 20210727 $i 1477-9137 $m Journal of cell science $n J Cell Sci $x MED00002576
- LZP __
- $a Pubmed-20211013