-
Je něco špatně v tomto záznamu ?
Comparison of human IgG glycopeptides separation using mixed-mode hydrophilic interaction/ion-exchange liquid chromatography and reversed-phase mode
K. Molnarova, A. Duris, T. Jecmen, P. Kozlik
Jazyk angličtina Země Německo
Typ dokumentu srovnávací studie, časopisecké články
Grantová podpora
19-18005Y
Akademie Věd České Republiky
SVV260560
charles university
LTC20078
Ministry of Education, Youth and Sports of the Czech Republic
NLK
ProQuest Central
od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2011-01-01 do Před 1 rokem
- MeSH
- chromatografie iontoměničová metody MeSH
- chromatografie s reverzní fází metody MeSH
- glykopeptidy izolace a purifikace MeSH
- hydrofobní a hydrofilní interakce MeSH
- imunoglobulin G izolace a purifikace MeSH
- isomerie MeSH
- lidé MeSH
- proteomika MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
Glycoproteomics is a challenging branch of proteomics because of the micro- and macro-heterogeneity of protein glycosylation. Hydrophilic interaction liquid chromatography (HILIC) is an advantageous alternative to reversed-phase chromatography for intact glycopeptide separation prior to their identification by mass spectrometry. Nowadays, several HILIC columns differing in used chemistries are commercially available. However, there is a lack of comparative studies assessing their performance, and thus providing guidance for the selection of an adequate stationary phase for different glycoproteomics applications. Here, we compare three HILIC columns recently developed by Advanced Chromatography Technologies (ACE)- with unfunctionalized (HILIC-A), polyhydroxy functionalized (HILIC-N), and aminopropyl functionalized (HILIC-B) silica- with a C18 reversed-phase column in the separation of human immunoglobulin G glycopeptides. HILIC-A and HILIC-B exhibit mixed-mode separation combining hydrophilic and ion-exchange interactions for analyte retention. Expectably, reversed-phase mode successfully separated clusters of immunoglobulin G1 and immunoglobulin G2 glycopeptides, which differ in amino acid sequence, but was not able to adequately separate different glycoforms of the same peptide. All ACE HILIC columns showed higher separation power for different glycoforms, and we show that each column separates a different group of glycopeptides more effectively than the others. Moreover, HILIC-A and HILIC-N columns separated the isobaric A2G1F1 glycopeptides of immunoglobulin G, and thus showed the potential for the elucidation of the structure of isomeric glycoforms. Furthermore, the possible retention mechanism for the HILIC columns is discussed on the basis of the determined chromatographic parameters.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21025422
- 003
- CZ-PrNML
- 005
- 20211026133829.0
- 007
- ta
- 008
- 211013s2021 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-021-03388-3 $2 doi
- 035 __
- $a (PubMed)34002272
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Molnarova, Katarina $u Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague 2, Czech Republic
- 245 10
- $a Comparison of human IgG glycopeptides separation using mixed-mode hydrophilic interaction/ion-exchange liquid chromatography and reversed-phase mode / $c K. Molnarova, A. Duris, T. Jecmen, P. Kozlik
- 520 9_
- $a Glycoproteomics is a challenging branch of proteomics because of the micro- and macro-heterogeneity of protein glycosylation. Hydrophilic interaction liquid chromatography (HILIC) is an advantageous alternative to reversed-phase chromatography for intact glycopeptide separation prior to their identification by mass spectrometry. Nowadays, several HILIC columns differing in used chemistries are commercially available. However, there is a lack of comparative studies assessing their performance, and thus providing guidance for the selection of an adequate stationary phase for different glycoproteomics applications. Here, we compare three HILIC columns recently developed by Advanced Chromatography Technologies (ACE)- with unfunctionalized (HILIC-A), polyhydroxy functionalized (HILIC-N), and aminopropyl functionalized (HILIC-B) silica- with a C18 reversed-phase column in the separation of human immunoglobulin G glycopeptides. HILIC-A and HILIC-B exhibit mixed-mode separation combining hydrophilic and ion-exchange interactions for analyte retention. Expectably, reversed-phase mode successfully separated clusters of immunoglobulin G1 and immunoglobulin G2 glycopeptides, which differ in amino acid sequence, but was not able to adequately separate different glycoforms of the same peptide. All ACE HILIC columns showed higher separation power for different glycoforms, and we show that each column separates a different group of glycopeptides more effectively than the others. Moreover, HILIC-A and HILIC-N columns separated the isobaric A2G1F1 glycopeptides of immunoglobulin G, and thus showed the potential for the elucidation of the structure of isomeric glycoforms. Furthermore, the possible retention mechanism for the HILIC columns is discussed on the basis of the determined chromatographic parameters.
- 650 _2
- $a chromatografie iontoměničová $x metody $7 D002852
- 650 _2
- $a chromatografie s reverzní fází $x metody $7 D056148
- 650 _2
- $a glykopeptidy $x izolace a purifikace $7 D006020
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hydrofobní a hydrofilní interakce $7 D057927
- 650 _2
- $a imunoglobulin G $x izolace a purifikace $7 D007074
- 650 _2
- $a isomerie $7 D007536
- 650 _2
- $a proteomika $7 D040901
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Duris, Ales $u Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague 2, Czech Republic
- 700 1_
- $a Jecmen, Tomas $u Department of Biochemistry, Faculty of Science, Charles University, 128 00, Prague 2, Czech Republic
- 700 1_
- $a Kozlik, Petr $u Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague 2, Czech Republic. kozlik@natur.cuni.cz
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 413, č. 16 (2021), s. 4321-4328
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34002272 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20211013 $b ABA008
- 991 __
- $a 20211026133835 $b ABA008
- 999 __
- $a ok $b bmc $g 1714459 $s 1145929
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 413 $c 16 $d 4321-4328 $e 20210517 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- GRA __
- $a 19-18005Y $p Akademie Věd České Republiky
- GRA __
- $a SVV260560 $p charles university
- GRA __
- $a LTC20078 $p Ministry of Education, Youth and Sports of the Czech Republic
- LZP __
- $a Pubmed-20211013