Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Comparison of human IgG glycopeptides separation using mixed-mode hydrophilic interaction/ion-exchange liquid chromatography and reversed-phase mode

K. Molnarova, A. Duris, T. Jecmen, P. Kozlik

. 2021 ; 413 (16) : 4321-4328. [pub] 20210517

Jazyk angličtina Země Německo

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21025422

Grantová podpora
19-18005Y Akademie Věd České Republiky
SVV260560 charles university
LTC20078 Ministry of Education, Youth and Sports of the Czech Republic

E-zdroje NLK Online Plný text

ProQuest Central od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 2011-01-01 do Před 1 rokem

Glycoproteomics is a challenging branch of proteomics because of the micro- and macro-heterogeneity of protein glycosylation. Hydrophilic interaction liquid chromatography (HILIC) is an advantageous alternative to reversed-phase chromatography for intact glycopeptide separation prior to their identification by mass spectrometry. Nowadays, several HILIC columns differing in used chemistries are commercially available. However, there is a lack of comparative studies assessing their performance, and thus providing guidance for the selection of an adequate stationary phase for different glycoproteomics applications. Here, we compare three HILIC columns recently developed by Advanced Chromatography Technologies (ACE)- with unfunctionalized (HILIC-A), polyhydroxy functionalized (HILIC-N), and aminopropyl functionalized (HILIC-B) silica- with a C18 reversed-phase column in the separation of human immunoglobulin G glycopeptides. HILIC-A and HILIC-B exhibit mixed-mode separation combining hydrophilic and ion-exchange interactions for analyte retention. Expectably, reversed-phase mode successfully separated clusters of immunoglobulin G1 and immunoglobulin G2 glycopeptides, which differ in amino acid sequence, but was not able to adequately separate different glycoforms of the same peptide. All ACE HILIC columns showed higher separation power for different glycoforms, and we show that each column separates a different group of glycopeptides more effectively than the others. Moreover, HILIC-A and HILIC-N columns separated the isobaric A2G1F1 glycopeptides of immunoglobulin G, and thus showed the potential for the elucidation of the structure of isomeric glycoforms. Furthermore, the possible retention mechanism for the HILIC columns is discussed on the basis of the determined chromatographic parameters.

000      
00000naa a2200000 a 4500
001      
bmc21025422
003      
CZ-PrNML
005      
20211026133829.0
007      
ta
008      
211013s2021 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00216-021-03388-3 $2 doi
035    __
$a (PubMed)34002272
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Molnarova, Katarina $u Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague 2, Czech Republic
245    10
$a Comparison of human IgG glycopeptides separation using mixed-mode hydrophilic interaction/ion-exchange liquid chromatography and reversed-phase mode / $c K. Molnarova, A. Duris, T. Jecmen, P. Kozlik
520    9_
$a Glycoproteomics is a challenging branch of proteomics because of the micro- and macro-heterogeneity of protein glycosylation. Hydrophilic interaction liquid chromatography (HILIC) is an advantageous alternative to reversed-phase chromatography for intact glycopeptide separation prior to their identification by mass spectrometry. Nowadays, several HILIC columns differing in used chemistries are commercially available. However, there is a lack of comparative studies assessing their performance, and thus providing guidance for the selection of an adequate stationary phase for different glycoproteomics applications. Here, we compare three HILIC columns recently developed by Advanced Chromatography Technologies (ACE)- with unfunctionalized (HILIC-A), polyhydroxy functionalized (HILIC-N), and aminopropyl functionalized (HILIC-B) silica- with a C18 reversed-phase column in the separation of human immunoglobulin G glycopeptides. HILIC-A and HILIC-B exhibit mixed-mode separation combining hydrophilic and ion-exchange interactions for analyte retention. Expectably, reversed-phase mode successfully separated clusters of immunoglobulin G1 and immunoglobulin G2 glycopeptides, which differ in amino acid sequence, but was not able to adequately separate different glycoforms of the same peptide. All ACE HILIC columns showed higher separation power for different glycoforms, and we show that each column separates a different group of glycopeptides more effectively than the others. Moreover, HILIC-A and HILIC-N columns separated the isobaric A2G1F1 glycopeptides of immunoglobulin G, and thus showed the potential for the elucidation of the structure of isomeric glycoforms. Furthermore, the possible retention mechanism for the HILIC columns is discussed on the basis of the determined chromatographic parameters.
650    _2
$a chromatografie iontoměničová $x metody $7 D002852
650    _2
$a chromatografie s reverzní fází $x metody $7 D056148
650    _2
$a glykopeptidy $x izolace a purifikace $7 D006020
650    _2
$a lidé $7 D006801
650    _2
$a hydrofobní a hydrofilní interakce $7 D057927
650    _2
$a imunoglobulin G $x izolace a purifikace $7 D007074
650    _2
$a isomerie $7 D007536
650    _2
$a proteomika $7 D040901
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Duris, Ales $u Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague 2, Czech Republic
700    1_
$a Jecmen, Tomas $u Department of Biochemistry, Faculty of Science, Charles University, 128 00, Prague 2, Czech Republic
700    1_
$a Kozlik, Petr $u Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 8, 128 43, Prague 2, Czech Republic. kozlik@natur.cuni.cz
773    0_
$w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 413, č. 16 (2021), s. 4321-4328
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34002272 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20211013 $b ABA008
991    __
$a 20211026133835 $b ABA008
999    __
$a ok $b bmc $g 1714459 $s 1145929
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 413 $c 16 $d 4321-4328 $e 20210517 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
GRA    __
$a 19-18005Y $p Akademie Věd České Republiky
GRA    __
$a SVV260560 $p charles university
GRA    __
$a LTC20078 $p Ministry of Education, Youth and Sports of the Czech Republic
LZP    __
$a Pubmed-20211013

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...