Highly Sensitive Voltammetric Determination of Acrylamide Based on Ibuprofen Capped Mercury Nanoparticles
Sirajuddin, ZA. Tagar, MA. Ul Haq, MR. Shah, . Mujeeb-Ur-Rehman, STH. Sherazi, J. Barek, MS. Kalhoro
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
Grantová podpora
20-01589S
Grantová Agentura České Republiky
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
34770608
DOI
10.3390/s21217302
Knihovny.cz E-zdroje
- MeSH
- akrylamid MeSH
- elektrochemické techniky MeSH
- elektrody MeSH
- ibuprofen MeSH
- nanočástice * MeSH
- rtuť * MeSH
- Publikační typ
- časopisecké články MeSH
Highly stable, small-sized and evenly distributed solid mercury nanoparticles capped with ibuprofen (Ibu-HgNPs) were prepared via reduction with hydrazine and capped with ibuprofen as a stabilizing agent. Characterization of Ibu-HgNPs was carried out by UV-Vis spectrophotometry and transmission electron microscopy (TEM). The prepared Ibu-HgNPs were immobilized onto a glassy carbon electrode (GCE) and used for the first time as the sensing element for voltammetric determination of low concentrations of acrylamide (AA) in aqueous solutions. Various parameters such as the type of supporting electrolyte, voltammetric mode, frequency, deposition time, stirring rate and initial potential were optimized to obtain the highest peak current of AA. The sensor delivered the best results in combination with the square wave voltammetry (SWV) mode, with good repeatability (relative standard deviation (RSD) of 25 repetitions was 1.4% for 1000 ppb AA). The study further revealed that Ibu-HgNPs are strongly adhered to GCE and hence do not contaminate the environment even after several runs. The newly developed AA sensor provides linear calibration dependence in the range of 100-1300 ppb with an R2 value of 0.996 and limit of detection (LOD) of 8.5 ppb. Negligible interference was confirmed from several organic compounds, cations and anions. The developed sensor was successfully applied for AA determination in various types of environmental real water samples to prove its practical usefulness and applicability.
Institute of Physics University of Sindh Jamshoro 76080 Pakistan
National Center of Excellence in Analytical Chemistry University of Sindh Jamshoro 76080 Pakistan
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22003253
- 003
- CZ-PrNML
- 005
- 20220210113618.0
- 007
- ta
- 008
- 220113s2021 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s21217302 $2 doi
- 035 __
- $a (PubMed)34770608
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Sirajuddin, $u International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan
- 245 10
- $a Highly Sensitive Voltammetric Determination of Acrylamide Based on Ibuprofen Capped Mercury Nanoparticles / $c Sirajuddin, ZA. Tagar, MA. Ul Haq, MR. Shah, . Mujeeb-Ur-Rehman, STH. Sherazi, J. Barek, MS. Kalhoro
- 520 9_
- $a Highly stable, small-sized and evenly distributed solid mercury nanoparticles capped with ibuprofen (Ibu-HgNPs) were prepared via reduction with hydrazine and capped with ibuprofen as a stabilizing agent. Characterization of Ibu-HgNPs was carried out by UV-Vis spectrophotometry and transmission electron microscopy (TEM). The prepared Ibu-HgNPs were immobilized onto a glassy carbon electrode (GCE) and used for the first time as the sensing element for voltammetric determination of low concentrations of acrylamide (AA) in aqueous solutions. Various parameters such as the type of supporting electrolyte, voltammetric mode, frequency, deposition time, stirring rate and initial potential were optimized to obtain the highest peak current of AA. The sensor delivered the best results in combination with the square wave voltammetry (SWV) mode, with good repeatability (relative standard deviation (RSD) of 25 repetitions was 1.4% for 1000 ppb AA). The study further revealed that Ibu-HgNPs are strongly adhered to GCE and hence do not contaminate the environment even after several runs. The newly developed AA sensor provides linear calibration dependence in the range of 100-1300 ppb with an R2 value of 0.996 and limit of detection (LOD) of 8.5 ppb. Negligible interference was confirmed from several organic compounds, cations and anions. The developed sensor was successfully applied for AA determination in various types of environmental real water samples to prove its practical usefulness and applicability.
- 650 _2
- $a akrylamid $7 D020106
- 650 _2
- $a elektrochemické techniky $7 D055664
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a ibuprofen $7 D007052
- 650 12
- $a rtuť $7 D008628
- 650 12
- $a nanočástice $7 D053758
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Tagar, Zulfiqar Ali $u National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan
- 700 1_
- $a Ul Haq, Muhammad Anwar $u International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan
- 700 1_
- $a Shah, Muhammad Raza $u International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan
- 700 1_
- $a Mujeeb-Ur-Rehman, $u International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan
- 700 1_
- $a Sherazi, Syed Tufail Hussain $u National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan
- 700 1_
- $a Barek, Jiri $u UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 6, CZ-15843 Prague, Czech Republic
- 700 1_
- $a Kalhoro, Muhammad Siddique $u Institute of Physics, University of Sindh, Jamshoro 76080, Pakistan
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 21, č. 21 (2021)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34770608 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220113 $b ABA008
- 991 __
- $a 20220210113612 $b ABA008
- 999 __
- $a ok $b bmc $g 1750877 $s 1154402
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 21 $c 21 $e 20211102 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- GRA __
- $a 20-01589S $p Grantová Agentura České Republiky
- LZP __
- $a Pubmed-20220113