-
Je něco špatně v tomto záznamu ?
Diffusion magnetic resonance imaging reveals tract-specific microstructural correlates of electrophysiological impairments in non-myelopathic and myelopathic spinal cord compression
J. Valošek, R. Labounek, T. Horák, M. Horáková, P. Bednařík, M. Keřkovský, J. Kočica, T. Rohan, C. Lenglet, J. Cohen-Adad, P. Hluštík, E. Vlčková, Z. Kadaňka, J. Bednařík, A. Svatkova
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, Research Support, N.I.H., Extramural, práce podpořená grantem
Grantová podpora
P41 EB027061
NIBIB NIH HHS - United States
CIHR FDN-143263
CIHR - Canada
P30 NS076408
NINDS NIH HHS - United States
PubMed
34288268
DOI
10.1111/ene.15027
Knihovny.cz E-zdroje
- MeSH
- difuzní magnetická rezonance MeSH
- komprese míchy * diagnostické zobrazování MeSH
- krční obratle diagnostické zobrazování MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- mícha diagnostické zobrazování MeSH
- nemoci míchy * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
BACKGROUND AND PURPOSE: Non-myelopathic degenerative cervical spinal cord compression (NMDC) frequently occurs throughout aging and may progress to potentially irreversible degenerative cervical myelopathy (DCM). Whereas standard clinical magnetic resonance imaging (MRI) and electrophysiological measures assess compression severity and neurological dysfunction, respectively, underlying microstructural deficits still have to be established in NMDC and DCM patients. The study aims to establish tract-specific diffusion MRI markers of electrophysiological deficits to predict the progression of asymptomatic NMDC to symptomatic DCM. METHODS: High-resolution 3 T diffusion MRI was acquired for 103 NMDC and 21 DCM patients compared to 60 healthy controls to reveal diffusion alterations and relationships between tract-specific diffusion metrics and corresponding electrophysiological measures and compression severity. Relationship between the degree of DCM disability, assessed by the modified Japanese Orthopaedic Association scale, and tract-specific microstructural changes in DCM patients was also explored. RESULTS: The study identified diffusion-derived abnormalities in the gray matter, dorsal and lateral tracts congruent with trans-synaptic degeneration and demyelination in chronic degenerative spinal cord compression with more profound alterations in DCM than NMDC. Diffusion metrics were affected in the C3-6 area as well as above the compression level at C3 with more profound rostral deficits in DCM than NMDC. Alterations in lateral motor and dorsal sensory tracts correlated with motor and sensory evoked potentials, respectively, whereas electromyography outcomes corresponded with gray matter microstructure. DCM disability corresponded with microstructure alteration in lateral columns. CONCLUSIONS: Outcomes imply the necessity of high-resolution tract-specific diffusion MRI for monitoring degenerative spinal pathology in longitudinal studies.
Central European Institute of Technology Masaryk University Brno Czechia
Department of Biomedical Engineering University Hospital Olomouc Czechia
Department of Neurology Faculty of Medicine and Dentistry Palacký University Olomouc Czechia
Department of Neurology University Hospital Brno Brno Czechia
Department of Radiology and Nuclear Medicine University Hospital Brno Brno Czechia
Faculty of Medicine Masaryk University Brno Czechia
Functional Neuroimaging Unit CRIUGM University of Montreal Montreal Quebec Canada
Mila Quebec AI Institute Montreal Quebec Canada
NeuroPoly Lab Institute of Biomedical Engineering Polytechnique Montreal Montreal Quebec Canada
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22003296
- 003
- CZ-PrNML
- 005
- 20220718085629.0
- 007
- ta
- 008
- 220113s2021 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/ene.15027 $2 doi
- 035 __
- $a (PubMed)34288268
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Valošek, Jan, $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University, Olomouc, Czechia $u Department of Biomedical Engineering, University Hospital, Olomouc, Czechia $d 1993- $7 xx0274853
- 245 10
- $a Diffusion magnetic resonance imaging reveals tract-specific microstructural correlates of electrophysiological impairments in non-myelopathic and myelopathic spinal cord compression / $c J. Valošek, R. Labounek, T. Horák, M. Horáková, P. Bednařík, M. Keřkovský, J. Kočica, T. Rohan, C. Lenglet, J. Cohen-Adad, P. Hluštík, E. Vlčková, Z. Kadaňka, J. Bednařík, A. Svatkova
- 520 9_
- $a BACKGROUND AND PURPOSE: Non-myelopathic degenerative cervical spinal cord compression (NMDC) frequently occurs throughout aging and may progress to potentially irreversible degenerative cervical myelopathy (DCM). Whereas standard clinical magnetic resonance imaging (MRI) and electrophysiological measures assess compression severity and neurological dysfunction, respectively, underlying microstructural deficits still have to be established in NMDC and DCM patients. The study aims to establish tract-specific diffusion MRI markers of electrophysiological deficits to predict the progression of asymptomatic NMDC to symptomatic DCM. METHODS: High-resolution 3 T diffusion MRI was acquired for 103 NMDC and 21 DCM patients compared to 60 healthy controls to reveal diffusion alterations and relationships between tract-specific diffusion metrics and corresponding electrophysiological measures and compression severity. Relationship between the degree of DCM disability, assessed by the modified Japanese Orthopaedic Association scale, and tract-specific microstructural changes in DCM patients was also explored. RESULTS: The study identified diffusion-derived abnormalities in the gray matter, dorsal and lateral tracts congruent with trans-synaptic degeneration and demyelination in chronic degenerative spinal cord compression with more profound alterations in DCM than NMDC. Diffusion metrics were affected in the C3-6 area as well as above the compression level at C3 with more profound rostral deficits in DCM than NMDC. Alterations in lateral motor and dorsal sensory tracts correlated with motor and sensory evoked potentials, respectively, whereas electromyography outcomes corresponded with gray matter microstructure. DCM disability corresponded with microstructure alteration in lateral columns. CONCLUSIONS: Outcomes imply the necessity of high-resolution tract-specific diffusion MRI for monitoring degenerative spinal pathology in longitudinal studies.
- 650 _2
- $a krční obratle $x diagnostické zobrazování $7 D002574
- 650 _2
- $a difuzní magnetická rezonance $7 D038524
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a magnetická rezonanční tomografie $7 D008279
- 650 _2
- $a mícha $x diagnostické zobrazování $7 D013116
- 650 12
- $a komprese míchy $x diagnostické zobrazování $7 D013117
- 650 12
- $a nemoci míchy $7 D013118
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a Research Support, N.I.H., Extramural $7 D052061
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Labounek, René $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University, Olomouc, Czechia $u Division of Clinical Behavioral Neuroscience, Department of Pediatrics, University of Minnesota, Minneapolis, Minnesota, USA
- 700 1_
- $a Horák, Tomáš $u Central European Institute of Technology, Masaryk University, Brno, Czechia $u Department of Neurology, University Hospital Brno, Brno, Czechia $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Horáková, Magda $u Department of Neurology, University Hospital Brno, Brno, Czechia $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Bednařík, Petr $u Central European Institute of Technology, Masaryk University, Brno, Czechia $u High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- 700 1_
- $a Keřkovský, Miloš $u Faculty of Medicine, Masaryk University, Brno, Czechia $u Department of Radiology and Nuclear Medicine, University Hospital Brno, Brno, Czechia
- 700 1_
- $a Kočica, Jan $u Department of Neurology, University Hospital Brno, Brno, Czechia $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Rohan, Tomáš $u Faculty of Medicine, Masaryk University, Brno, Czechia $u Department of Radiology and Nuclear Medicine, University Hospital Brno, Brno, Czechia
- 700 1_
- $a Lenglet, Christophe $u Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
- 700 1_
- $a Cohen-Adad, Julien $u NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada $u Functional Neuroimaging Unit, CRIUGM, University of Montreal, Montreal, Quebec, Canada $u Mila - Quebec AI Institute, Montreal, Quebec, Canada
- 700 1_
- $a Hluštík, Petr $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University, Olomouc, Czechia
- 700 1_
- $a Vlčková, Eva $u Department of Neurology, University Hospital Brno, Brno, Czechia $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Kadaňka, Zdeněk $u Department of Neurology, University Hospital Brno, Brno, Czechia $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Bednařík, Josef $u Central European Institute of Technology, Masaryk University, Brno, Czechia $u Department of Neurology, University Hospital Brno, Brno, Czechia $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Svatkova, Alena $u Central European Institute of Technology, Masaryk University, Brno, Czechia $u Department of Medicine III, Clinical Division of Endocrinology and Metabolism, Medical University of Vienna, Vienna, Austria
- 773 0_
- $w MED00001629 $t European journal of neurology $x 1468-1331 $g Roč. 28, č. 11 (2021), s. 3784-3797
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34288268 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220113 $b ABA008
- 991 __
- $a 20220718085628 $b ABA008
- 999 __
- $a ok $b bmc $g 1750913 $s 1154445
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 28 $c 11 $d 3784-3797 $e 20210804 $i 1468-1331 $m European journal of neurology $n Eur J Neurol $x MED00001629
- GRA __
- $a P41 EB027061 $p NIBIB NIH HHS $2 United States
- GRA __
- $a CIHR FDN-143263 $p CIHR $2 Canada
- GRA __
- $a P30 NS076408 $p NINDS NIH HHS $2 United States
- LZP __
- $a Pubmed-20220113