-
Something wrong with this record ?
Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated Dataset for PPG Quality Assessment and Heart Rate Estimation
A. Nemcova, E. Vargova, R. Smisek, L. Marsanova, L. Smital, M. Vitek
Language English Country United States
Document type Dataset, Journal Article
NLK
Free Medical Journals
from 2013
PubMed Central
from 2013
Europe PubMed Central
from 2013
ProQuest Central
from 2013
Open Access Digital Library
from 2001-01-01
Open Access Digital Library
from 2012-12-04
Open Access Digital Library
from 2013-01-01
CINAHL Plus with Full Text (EBSCOhost)
from 2013-01-01
Medline Complete (EBSCOhost)
from 2013-01-01
Health & Medicine (ProQuest)
from 2013
Wiley-Blackwell Open Access Titles
from 2001
ROAD: Directory of Open Access Scholarly Resources
from 2013
PubMed
34532501
DOI
10.1155/2021/3453007
Knihovny.cz E-resources
- MeSH
- Algorithms MeSH
- Artifacts MeSH
- Smartphone MeSH
- Databases, Factual * MeSH
- Adult MeSH
- Electrocardiography MeSH
- Photoplethysmography statistics & numerical data MeSH
- Middle Aged MeSH
- Humans MeSH
- Signal Processing, Computer-Assisted instrumentation MeSH
- Reference Values MeSH
- Reference Standards MeSH
- Heart Rate physiology MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Dataset MeSH
- Geographicals
- Czech Republic MeSH
To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22003763
- 003
- CZ-PrNML
- 005
- 20250507092836.0
- 007
- ta
- 008
- 220113e20210906xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1155/2021/3453007 $2 doi
- 035 __
- $a (PubMed)34532501
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Němcová, Andrea $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic $7 xx0331813
- 245 10
- $a Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated Dataset for PPG Quality Assessment and Heart Rate Estimation / $c A. Nemcova, E. Vargova, R. Smisek, L. Marsanova, L. Smital, M. Vitek
- 520 9_
- $a To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a artefakty $7 D016477
- 650 12
- $a databáze faktografické $7 D016208
- 650 _2
- $a elektrokardiografie $7 D004562
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a srdeční frekvence $x fyziologie $7 D006339
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a fotopletysmografie $x statistika a číselné údaje $7 D017156
- 650 _2
- $a referenční standardy $7 D012015
- 650 _2
- $a referenční hodnoty $7 D012016
- 650 _2
- $a počítačové zpracování signálu $x přístrojové vybavení $7 D012815
- 650 _2
- $a chytrý telefon $7 D000068997
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a dataset $7 D064886
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Vargová, Enikö $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic $7 xx0331812
- 700 1_
- $a Smisek, Radovan $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic $u Institute of Scientific Instruments, The Czech Academy of Sciences, Kralovopolska 147, Brno 612 64, Czech Republic
- 700 1_
- $a Marsanova, Lucie $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic
- 700 1_
- $a Smital, Lukas $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic
- 700 1_
- $a Vitek, Martin $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic
- 773 0_
- $w MED00182164 $t BioMed research international $x 2314-6141 $g Roč. 2021 (20210906), s. 3453007
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34532501 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220113 $b ABA008
- 991 __
- $a 20250507092834 $b ABA008
- 999 __
- $a ok $b bmc $g 1751271 $s 1154912
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 2021 $c - $d 3453007 $e 20210906 $i 2314-6141 $m BioMed research international $n Biomed Res Int $x MED00182164
- LZP __
- $a Pubmed-20220113