Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated Dataset for PPG Quality Assessment and Heart Rate Estimation

A. Nemcova, E. Vargova, R. Smisek, L. Marsanova, L. Smital, M. Vitek

. 2021 ; 2021 (-) : 3453007. [pub] 20210906

Language English Country United States

Document type Dataset, Journal Article

To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22003763
003      
CZ-PrNML
005      
20250507092836.0
007      
ta
008      
220113e20210906xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1155/2021/3453007 $2 doi
035    __
$a (PubMed)34532501
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Němcová, Andrea $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic $7 xx0331813
245    10
$a Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated Dataset for PPG Quality Assessment and Heart Rate Estimation / $c A. Nemcova, E. Vargova, R. Smisek, L. Marsanova, L. Smital, M. Vitek
520    9_
$a To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.
650    _2
$a dospělí $7 D000328
650    _2
$a algoritmy $7 D000465
650    _2
$a artefakty $7 D016477
650    12
$a databáze faktografické $7 D016208
650    _2
$a elektrokardiografie $7 D004562
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a srdeční frekvence $x fyziologie $7 D006339
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a fotopletysmografie $x statistika a číselné údaje $7 D017156
650    _2
$a referenční standardy $7 D012015
650    _2
$a referenční hodnoty $7 D012016
650    _2
$a počítačové zpracování signálu $x přístrojové vybavení $7 D012815
650    _2
$a chytrý telefon $7 D000068997
651    _2
$a Česká republika $7 D018153
655    _2
$a dataset $7 D064886
655    _2
$a časopisecké články $7 D016428
700    1_
$a Vargová, Enikö $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic $7 xx0331812
700    1_
$a Smisek, Radovan $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic $u Institute of Scientific Instruments, The Czech Academy of Sciences, Kralovopolska 147, Brno 612 64, Czech Republic
700    1_
$a Marsanova, Lucie $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic
700    1_
$a Smital, Lukas $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic
700    1_
$a Vitek, Martin $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 12, Brno 616 00, Czech Republic
773    0_
$w MED00182164 $t BioMed research international $x 2314-6141 $g Roč. 2021 (20210906), s. 3453007
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34532501 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20250507092834 $b ABA008
999    __
$a ok $b bmc $g 1751271 $s 1154912
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 2021 $c - $d 3453007 $e 20210906 $i 2314-6141 $m BioMed research international $n Biomed Res Int $x MED00182164
LZP    __
$a Pubmed-20220113

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...