Lab-In-Syringe with Bead Injection Coupled Online to High-Performance Liquid Chromatography as Versatile Tool for Determination of Nonsteroidal Anti-Inflammatory Drugs in Surface Waters
CV. Gemuh, B. Horstkotte, P. Solich
Language English Country Switzerland
Document type Journal Article
Grant support
CZ.02.1.01/0.0/0.0/15_003/0000465
European Regional Development Fund
1070120
Grantová Agentura, Univerzita Karlova
SVV 260 548
Charles University, Faculty of Pharmacy
NLK
Directory of Open Access Journals
from 1997
Free Medical Journals
from 1997
PubMed Central
from 2001
Europe PubMed Central
from 2001
ProQuest Central
from 1997-01-01
Open Access Digital Library
from 1997-01-01
Medline Complete (EBSCOhost)
from 2009-03-01
Health & Medicine (ProQuest)
from 1997-01-01
- MeSH
- Anti-Inflammatory Agents, Non-Steroidal analysis MeSH
- Solid Phase Extraction * MeSH
- Surface Properties MeSH
- Water chemistry MeSH
- Chromatography, High Pressure Liquid MeSH
- Publication type
- Journal Article MeSH
We report on the hyphenation of the modern flow techniques Lab-In-Syringe and Lab-On-Valve for automated sample preparation coupled online with high-performance liquid chromatography. Adopting the bead injection concept on the Lab-On-Valve platform, the on-demand, renewable, solid-phase extraction of five nonsteroidal anti-inflammatory drugs, namely ketoprofen, naproxen, flurbiprofen, diclofenac, and ibuprofen, was carried out as a proof-of-concept. In-syringe mixing of the sample with buffer and standards allowed straightforward pre-load sample modification for the preconcentration of large sample volumes. Packing of ca. 4.4 mg microSPE columns from Oasis HLB® sorbent slurry was performed for each sample analysis using a simple microcolumn adapted to the Lab-On-Valve manifold to achieve low backpressure during loading. Eluted analytes were injected into online coupled HPLC with subsequent separation on a Symmetry C18 column in isocratic mode. The optimized method was highly reproducible, with RSD values of 3.2% to 7.6% on 20 µg L-1 level. Linearity was confirmed up to 200 µg L-1 and LOD values were between 0.06 and 1.98 µg L-1. Recovery factors between 91 and 109% were obtained in the analysis of spiked surface water samples.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22003770
- 003
- CZ-PrNML
- 005
- 20220127145900.0
- 007
- ta
- 008
- 220113s2021 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/molecules26175358 $2 doi
- 035 __
- $a (PubMed)34500791
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Gemuh, Celestine Vubangsi $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
- 245 10
- $a Lab-In-Syringe with Bead Injection Coupled Online to High-Performance Liquid Chromatography as Versatile Tool for Determination of Nonsteroidal Anti-Inflammatory Drugs in Surface Waters / $c CV. Gemuh, B. Horstkotte, P. Solich
- 520 9_
- $a We report on the hyphenation of the modern flow techniques Lab-In-Syringe and Lab-On-Valve for automated sample preparation coupled online with high-performance liquid chromatography. Adopting the bead injection concept on the Lab-On-Valve platform, the on-demand, renewable, solid-phase extraction of five nonsteroidal anti-inflammatory drugs, namely ketoprofen, naproxen, flurbiprofen, diclofenac, and ibuprofen, was carried out as a proof-of-concept. In-syringe mixing of the sample with buffer and standards allowed straightforward pre-load sample modification for the preconcentration of large sample volumes. Packing of ca. 4.4 mg microSPE columns from Oasis HLB® sorbent slurry was performed for each sample analysis using a simple microcolumn adapted to the Lab-On-Valve manifold to achieve low backpressure during loading. Eluted analytes were injected into online coupled HPLC with subsequent separation on a Symmetry C18 column in isocratic mode. The optimized method was highly reproducible, with RSD values of 3.2% to 7.6% on 20 µg L-1 level. Linearity was confirmed up to 200 µg L-1 and LOD values were between 0.06 and 1.98 µg L-1. Recovery factors between 91 and 109% were obtained in the analysis of spiked surface water samples.
- 650 _2
- $a antiflogistika nesteroidní $x analýza $7 D000894
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 12
- $a extrakce na pevné fázi $7 D052616
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 650 _2
- $a voda $x chemie $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Horstkotte, Burkhard $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
- 700 1_
- $a Solich, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
- 773 0_
- $w MED00180394 $t Molecules (Basel, Switzerland) $x 1420-3049 $g Roč. 26, č. 17 (2021)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34500791 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220113 $b ABA008
- 991 __
- $a 20220127145856 $b ABA008
- 999 __
- $a ok $b bmc $g 1751278 $s 1154919
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 26 $c 17 $e 20210903 $i 1420-3049 $m Molecules $n Molecules $x MED00180394
- GRA __
- $a CZ.02.1.01/0.0/0.0/15_003/0000465 $p European Regional Development Fund
- GRA __
- $a 1070120 $p Grantová Agentura, Univerzita Karlova
- GRA __
- $a SVV 260 548 $p Charles University, Faculty of Pharmacy
- LZP __
- $a Pubmed-20220113