The time has come to extend the expiration limit of cryopreserved allograft heart valves

J. Burkert, P. Kochová, Z. Tonar, R. Cimrman, T. Blassová, R. Jashari, R. Fiala, J. Špatenka

. 2021 ; 22 (2) : 161-184. [pub] 20200624

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc22004253

Grantová podpora
LO1506 Czech Ministry of Education, Youth and Sports - NPU I
LO1503 Czech Ministry of Education, Youth and Sports - NPU I
CZ.02.1.01/0.0/0.0/17_048/0007280 European Regional Development Fund-Project "Application of Modern Technologies in Medicine and Industry"
Progres Q39 Charles University Research Fund

E-zdroje Online Plný text

NLK ProQuest Central od 2000-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2011-02-01 do Před 1 rokem
Nursing & Allied Health Database (ProQuest) od 2000-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 2000-01-01 do Před 1 rokem

Despite the wide choice of commercial heart valve prostheses, cryopreserved semilunar allograft heart valves (C-AHV) are required, and successfully transplanted in selected groups of patients. The expiration limit (EL) criteria have not been defined yet. Most Tissue Establishments (TE) use the EL of 5 years. From physiological, functional, and surgical point of view, the morphology and mechanical properties of aortic and pulmonary roots represent basic features limiting the EL of C-AHV. The aim of this work was to review methods of AHV tissue structural analysis and mechanical testing from the perspective of suitability for EL validation studies. Microscopic structure analysis of great arterial wall and semilunar leaflets tissue should clearly demonstrate cells as well as the extracellular matrix components by highly reproducible and specific histological staining procedures. Quantitative morphometry using stereological grids has proved to be effective, as the exact statistics was feasible. From mechanical testing methods, tensile test was the most suitable. Young's moduli of elasticity, ultimate stress and strain were shown to represent most important AHV tissue mechanical characteristics, suitable for exact statistical analysis. C-AHV are prepared by many different protocols, so as each TE has to work out own EL for C-AHV.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22004253
003      
CZ-PrNML
005      
20220127145411.0
007      
ta
008      
220113s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s10561-020-09843-2 $2 doi
035    __
$a (PubMed)32583302
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Burkert, Jan $u Department of Transplantation and Tissue Banking, Czech National Allograft Heart Valve Bank, Department of Cardiovascular Surgery, Motol University Hospital, and Second Faculty of Medicine Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic
245    14
$a The time has come to extend the expiration limit of cryopreserved allograft heart valves / $c J. Burkert, P. Kochová, Z. Tonar, R. Cimrman, T. Blassová, R. Jashari, R. Fiala, J. Špatenka
520    9_
$a Despite the wide choice of commercial heart valve prostheses, cryopreserved semilunar allograft heart valves (C-AHV) are required, and successfully transplanted in selected groups of patients. The expiration limit (EL) criteria have not been defined yet. Most Tissue Establishments (TE) use the EL of 5 years. From physiological, functional, and surgical point of view, the morphology and mechanical properties of aortic and pulmonary roots represent basic features limiting the EL of C-AHV. The aim of this work was to review methods of AHV tissue structural analysis and mechanical testing from the perspective of suitability for EL validation studies. Microscopic structure analysis of great arterial wall and semilunar leaflets tissue should clearly demonstrate cells as well as the extracellular matrix components by highly reproducible and specific histological staining procedures. Quantitative morphometry using stereological grids has proved to be effective, as the exact statistics was feasible. From mechanical testing methods, tensile test was the most suitable. Young's moduli of elasticity, ultimate stress and strain were shown to represent most important AHV tissue mechanical characteristics, suitable for exact statistical analysis. C-AHV are prepared by many different protocols, so as each TE has to work out own EL for C-AHV.
650    _2
$a alografty $7 D064591
650    _2
$a aorta $7 D001011
650    12
$a aortální chlopeň $x chirurgie $7 D001021
650    12
$a kryoprezervace $7 D015925
650    _2
$a modul pružnosti $7 D055119
650    _2
$a lidé $7 D006801
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Kochová, Petra $u Department of Transplantation and Tissue Banking, Czech National Allograft Heart Valve Bank, Department of Cardiovascular Surgery, Motol University Hospital, and Second Faculty of Medicine Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic. kochovap@ntc.zcu.cz $u NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Technická 8, Pilsen, Czech Republic. kochovap@ntc.zcu.cz
700    1_
$a Tonar, Zbyněk $u NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Technická 8, Pilsen, Czech Republic $u Department of Histology and Embryology, Biomedical Centre, Faculty of Medicine in Pilsen, Charles University in Prague, Karlovarská 48, 301 66, Pilsen, Czech Republic
700    1_
$a Cimrman, Robert $u NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Technická 8, Pilsen, Czech Republic
700    1_
$a Blassová, Tereza $u Department of Histology and Embryology, Biomedical Centre, Faculty of Medicine in Pilsen, Charles University in Prague, Karlovarská 48, 301 66, Pilsen, Czech Republic
700    1_
$a Jashari, Ramadan $u European Homograft Bank, Saint-Jean Clinic, Rue du Meridien 100, 1210, Brussels, Belgium
700    1_
$a Fiala, Radovan $u Department of Transplantation and Tissue Banking, Czech National Allograft Heart Valve Bank, Department of Cardiovascular Surgery, Motol University Hospital, and Second Faculty of Medicine Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic
700    1_
$a Špatenka, Jaroslav $u Department of Transplantation and Tissue Banking, Czech National Allograft Heart Valve Bank, Department of Cardiovascular Surgery, Motol University Hospital, and Second Faculty of Medicine Charles University in Prague, V Úvalu 84, 150 06, Prague, Czech Republic
773    0_
$w MED00007567 $t Cell and tissue banking $x 1573-6814 $g Roč. 22, č. 2 (2021), s. 161-184
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32583302 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127145408 $b ABA008
999    __
$a ok $b bmc $g 1751650 $s 1155402
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 22 $c 2 $d 161-184 $e 20200624 $i 1573-6814 $m Cell and tissue banking $n Cell Tissue Bank $x MED00007567
GRA    __
$a LO1506 $p Czech Ministry of Education, Youth and Sports - NPU I
GRA    __
$a LO1503 $p Czech Ministry of Education, Youth and Sports - NPU I
GRA    __
$a CZ.02.1.01/0.0/0.0/17_048/0007280 $p European Regional Development Fund-Project "Application of Modern Technologies in Medicine and Industry"
GRA    __
$a Progres Q39 $p Charles University Research Fund
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...