Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Dlouhodobé výsledky totální náhrady kolenního kloubu P.F.C. Sigma s celopolyetylenovou tibiální komponentou
[Long-Term Results of Total Knee Replacement Using P.F.C. Sigma System with an All-Polyethylene Tibial Component]

L. Nachtnebl, T. Tomáš, V. Apostolopoulos, L. Pazourek, M. Mahdal

. 2021 ; 88 (6) : 412-417. [pub] 20211220

Jazyk čeština Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22005928

Digitální knihovna NLK
Zdroj

E-zdroje Online

NLK Free Medical Journals od 2006

PURPOSE OF THE STUDY Use of an all-polyethylene (all-poly, AP) tibial component in primary total knee arthroplasty is still an attractive option considering the durability of replacement, the elimination of backside wear and the lower cost compared to modular metalbacked tibia. The purpose of the study was to evaluate the long-term results of the total knee replacement using the P.F.C. Sigma system with a monoblock all-polyethylene tibial component implanted at the 1st Orthopedic Department of the St. Anne's University Hospital and Masaryk University Brno in the period 1999-2010. MATERIAL AND METHODS In the monitored period, 911 total knee replacements using P.F.C. Sigma with an all-polyethylene tibial component were performed. This cohort of patients was evaluated at least 10 years after the primary replacement surgery. Altogether 323 knee replacements in 289 patients were evaluated. The clinical outcomes were assessed according to the Knee Society Clinical Rating System (KSS) and the Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. The replacement survival was evaluated using the Kaplan-Meier survival analysis. RESULTS In the evaluated group, the average KS was 82.6 points and the average functional score was 74.7 points. Excellent results were recorded in 213 cases, good results in 78 and satisfactory in 23 replacements. Poor clinical results were reported in 9 patients. The average range of motion was 105.8°. In 5 knees (1.5%) revision surgery was performed for infection complications, 3 cases were complicated due to periprosthetic fractures, 4 replacements were revised due to anterior knee pain and 8 knees showed a limited range of motion. Only 1 replacement was revised for aseptic loosening, with no need for reimplantation of the component. The survivorship of the implant was 98.5 % at the follow-up of 12.8 years, including the reasons of reimplantation. DISCUSSION Total knee replacement with an all-polyethylene tibial component is not so popular as the metal-backed modular implants. The all-polyethylene tibial component has certain advantages: lower unit costs, no backside wear, no liner dislocation, possibility of conservative bone resection. On the other hand, this type of implant is not modular and augmentations or longer stems cannot be used. Even though this type of endoprosthesis is recommended exclusively for elderly patients with a lower level of activity, the current mid- and long-term results show that indications for all-poly implants are much broader. CONCLUSIONS The total knee replacement with an all-polyethylene tibial component shows very good long-term clinical outcomes with an excellent survival rate. The all-poly design is cost-effective and may be used not only in elderly patients. Key words: total knee replacement, all-polyethylene tibial component, long-term results.

Long-Term Results of Total Knee Replacement Using P.F.C. Sigma System with an All-Polyethylene Tibial Component

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc22005928
003      
CZ-PrNML
005      
20220224144211.0
007      
ta
008      
220207s2021 xr ad f 000 0|cze||
009      
AR
024    7_
$2 doi $a 10.55095/achot2021/061
035    __
$a (PubMed)34998443
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Nachtnebl, Luboš $7 xx0106708 $u I. ortopedická klinika Fakultní nemocnice U sv. Anny v Brně, Lékařská fakulta Masarykovy univerzity, Brno
245    10
$a Dlouhodobé výsledky totální náhrady kolenního kloubu P.F.C. Sigma s celopolyetylenovou tibiální komponentou / $c L. Nachtnebl, T. Tomáš, V. Apostolopoulos, L. Pazourek, M. Mahdal
246    31
$a Long-Term Results of Total Knee Replacement Using P.F.C. Sigma System with an All-Polyethylene Tibial Component
504    __
$a Literatura
520    9_
$a PURPOSE OF THE STUDY Use of an all-polyethylene (all-poly, AP) tibial component in primary total knee arthroplasty is still an attractive option considering the durability of replacement, the elimination of backside wear and the lower cost compared to modular metalbacked tibia. The purpose of the study was to evaluate the long-term results of the total knee replacement using the P.F.C. Sigma system with a monoblock all-polyethylene tibial component implanted at the 1st Orthopedic Department of the St. Anne's University Hospital and Masaryk University Brno in the period 1999-2010. MATERIAL AND METHODS In the monitored period, 911 total knee replacements using P.F.C. Sigma with an all-polyethylene tibial component were performed. This cohort of patients was evaluated at least 10 years after the primary replacement surgery. Altogether 323 knee replacements in 289 patients were evaluated. The clinical outcomes were assessed according to the Knee Society Clinical Rating System (KSS) and the Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. The replacement survival was evaluated using the Kaplan-Meier survival analysis. RESULTS In the evaluated group, the average KS was 82.6 points and the average functional score was 74.7 points. Excellent results were recorded in 213 cases, good results in 78 and satisfactory in 23 replacements. Poor clinical results were reported in 9 patients. The average range of motion was 105.8°. In 5 knees (1.5%) revision surgery was performed for infection complications, 3 cases were complicated due to periprosthetic fractures, 4 replacements were revised due to anterior knee pain and 8 knees showed a limited range of motion. Only 1 replacement was revised for aseptic loosening, with no need for reimplantation of the component. The survivorship of the implant was 98.5 % at the follow-up of 12.8 years, including the reasons of reimplantation. DISCUSSION Total knee replacement with an all-polyethylene tibial component is not so popular as the metal-backed modular implants. The all-polyethylene tibial component has certain advantages: lower unit costs, no backside wear, no liner dislocation, possibility of conservative bone resection. On the other hand, this type of implant is not modular and augmentations or longer stems cannot be used. Even though this type of endoprosthesis is recommended exclusively for elderly patients with a lower level of activity, the current mid- and long-term results show that indications for all-poly implants are much broader. CONCLUSIONS The total knee replacement with an all-polyethylene tibial component shows very good long-term clinical outcomes with an excellent survival rate. The all-poly design is cost-effective and may be used not only in elderly patients. Key words: total knee replacement, all-polyethylene tibial component, long-term results.
650    _2
$a senioři $7 D000368
650    12
$a totální endoprotéza kolene $x škodlivé účinky $7 D019645
650    _2
$a následné studie $7 D005500
650    _2
$a lidé $7 D006801
650    12
$a protézy kolene $7 D007720
650    _2
$a polyethylen $7 D020959
650    _2
$a protézy - design $7 D011474
650    _2
$a selhání protézy $7 D011475
650    _2
$a reoperace $7 D012086
650    _2
$a tibie $x chirurgie $7 D013977
655    _2
$a časopisecké články $7 D016428
700    1_
$a Tomáš, Tomáš $7 ola2006319238 $u I. ortopedická klinika Fakultní nemocnice U sv. Anny v Brně, Lékařská fakulta Masarykovy univerzity, Brno
700    1_
$a Apostolopoulos, Vasileios. $7 xx0269825 $u I. ortopedická klinika Fakultní nemocnice U sv. Anny v Brně, Lékařská fakulta Masarykovy univerzity, Brno
700    1_
$a Pazourek, Lukáš $7 xx0123254 $u I. ortopedická klinika Fakultní nemocnice U sv. Anny v Brně, Lékařská fakulta Masarykovy univerzity, Brno
700    1_
$a Mahdal, Michal $7 xx0254094 $u I. ortopedická klinika Fakultní nemocnice U sv. Anny v Brně, Lékařská fakulta Masarykovy univerzity, Brno
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca $x 0001-5415 $g Roč. 88, č. 6 (2021), s. 412-417
856    41
$u https://achot.cz/pdfs/ach/2021/06/02.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 8 $c 507 $y p $z 0
990    __
$a 20220207 $b ABA008
991    __
$a 20220224144159 $b ABA008
999    __
$a ok $b bmc $g 1763610 $s 1157080
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 88 $c 6 $d 412-417 $e 20211220 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$b NLK118 $a Pubmed-20220207

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...