• Je něco špatně v tomto záznamu ?

Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens

M. Fus, S. Pitrova

. 2021 ; 15 (-) : 4755-4761. [pub] 20211219

Jazyk angličtina Země Nový Zéland

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22010433

Purpose: The aim of this study was to develop software for the universal objective evaluation of factors influencing intraocular correction of astigmatism, such as decentration, tilt, axial position and angular orientation the toric intraocular lens (IOL). Patients and Methods: Software was developed using the MS Visual Studio environment. The analysis was presented using images of 67 eyes with an implanted IOLs of the SN6ATx model series. Decentration and angular position of the lens were obtained from images of the anterior segment of the eye, using a Visucam unit. Tilt was measured on tomographic images from OCT Avanti (in meridian of highest tilt and perpendicular meridian) and preoperative biometry parameters of eye (axial length, anterior chamber depth - ACD, ocular lens thickness - LT, limbus diameter and mean keratometry value) including postoperative anterior chamber depth (pACD) were measured using Lenstar LS900. Results: Applying the software methodology to the evaluation of individual toric IOL parameters, the following results were obtained: mean decentration 0.25 ± 0.17 mm which was observed in 61.19% of eyes, mean misalignment to the planned axis equal to 3.8 ± 3.6 degrees, mean highest inclination equal to 3.7 ± 1.2 degrees and mean difference of pACD and ACD was equal to 1.46 ± 0.31 mm. There was only a weak nonsignificant correlation between preoperative ACD versus decentration and tilt of IOL or a weak significant correlation between preoperative LT and both decentration and misalignment of IOL. Conclusion: The use of the presented methodology for determining the positional parameters of the toric IOL provided comparable results with the results of recent studies. Software design can be considered as a suitable alternative to previously published techniques, with the significant advantage of the possibility of using universal input images, their graphical editing and especially the possibility of comprehensive analysis of all parameters.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22010433
003      
CZ-PrNML
005      
20220425131828.0
007      
ta
008      
220420s2021 nz f 000 0|eng||
009      
AR
024    7_
$a 10.2147/OPTH.S346968 $2 doi
035    __
$a (PubMed)34983999
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a nz
100    1_
$a Fus, Martin $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic $1 https://orcid.org/0000000332454544
245    10
$a Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens / $c M. Fus, S. Pitrova
520    9_
$a Purpose: The aim of this study was to develop software for the universal objective evaluation of factors influencing intraocular correction of astigmatism, such as decentration, tilt, axial position and angular orientation the toric intraocular lens (IOL). Patients and Methods: Software was developed using the MS Visual Studio environment. The analysis was presented using images of 67 eyes with an implanted IOLs of the SN6ATx model series. Decentration and angular position of the lens were obtained from images of the anterior segment of the eye, using a Visucam unit. Tilt was measured on tomographic images from OCT Avanti (in meridian of highest tilt and perpendicular meridian) and preoperative biometry parameters of eye (axial length, anterior chamber depth - ACD, ocular lens thickness - LT, limbus diameter and mean keratometry value) including postoperative anterior chamber depth (pACD) were measured using Lenstar LS900. Results: Applying the software methodology to the evaluation of individual toric IOL parameters, the following results were obtained: mean decentration 0.25 ± 0.17 mm which was observed in 61.19% of eyes, mean misalignment to the planned axis equal to 3.8 ± 3.6 degrees, mean highest inclination equal to 3.7 ± 1.2 degrees and mean difference of pACD and ACD was equal to 1.46 ± 0.31 mm. There was only a weak nonsignificant correlation between preoperative ACD versus decentration and tilt of IOL or a weak significant correlation between preoperative LT and both decentration and misalignment of IOL. Conclusion: The use of the presented methodology for determining the positional parameters of the toric IOL provided comparable results with the results of recent studies. Software design can be considered as a suitable alternative to previously published techniques, with the significant advantage of the possibility of using universal input images, their graphical editing and especially the possibility of comprehensive analysis of all parameters.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Pitrova, Sarka $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
773    0_
$w MED00165196 $t Clinical ophthalmology (Auckland, N.Z.) $x 1177-5467 $g Roč. 15, č. - (2021), s. 4755-4761
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34983999 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20220420 $b ABA008
991    __
$a 20220425131826 $b ABA008
999    __
$a ind $b bmc $g 1784590 $s 1161631
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 15 $c - $d 4755-4761 $e 20211219 $i 1177-5467 $m Clinical ophthalmology $n Clin Ophthalmol $x MED00165196
LZP    __
$a Pubmed-20220420

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...