Je něco špatně v tomto záznamu ?
Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens
M. Fus, S. Pitrova
Jazyk angličtina Země Nový Zéland
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2007
Free Medical Journals
od 2007
Freely Accessible Science Journals
od 2007
PubMed Central
od 2007
Europe PubMed Central
od 2007
ProQuest Central
od 2007-01-01
Open Access Digital Library
od 2007-01-01
Open Access Digital Library
od 2007-01-01
Taylor & Francis Open Access
od 2007-12-01
Health & Medicine (ProQuest)
od 2007-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2007
PubMed
34983999
DOI
10.2147/opth.s346968
Knihovny.cz E-zdroje
- Publikační typ
- časopisecké články MeSH
Purpose: The aim of this study was to develop software for the universal objective evaluation of factors influencing intraocular correction of astigmatism, such as decentration, tilt, axial position and angular orientation the toric intraocular lens (IOL). Patients and Methods: Software was developed using the MS Visual Studio environment. The analysis was presented using images of 67 eyes with an implanted IOLs of the SN6ATx model series. Decentration and angular position of the lens were obtained from images of the anterior segment of the eye, using a Visucam unit. Tilt was measured on tomographic images from OCT Avanti (in meridian of highest tilt and perpendicular meridian) and preoperative biometry parameters of eye (axial length, anterior chamber depth - ACD, ocular lens thickness - LT, limbus diameter and mean keratometry value) including postoperative anterior chamber depth (pACD) were measured using Lenstar LS900. Results: Applying the software methodology to the evaluation of individual toric IOL parameters, the following results were obtained: mean decentration 0.25 ± 0.17 mm which was observed in 61.19% of eyes, mean misalignment to the planned axis equal to 3.8 ± 3.6 degrees, mean highest inclination equal to 3.7 ± 1.2 degrees and mean difference of pACD and ACD was equal to 1.46 ± 0.31 mm. There was only a weak nonsignificant correlation between preoperative ACD versus decentration and tilt of IOL or a weak significant correlation between preoperative LT and both decentration and misalignment of IOL. Conclusion: The use of the presented methodology for determining the positional parameters of the toric IOL provided comparable results with the results of recent studies. Software design can be considered as a suitable alternative to previously published techniques, with the significant advantage of the possibility of using universal input images, their graphical editing and especially the possibility of comprehensive analysis of all parameters.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22010433
- 003
- CZ-PrNML
- 005
- 20220425131828.0
- 007
- ta
- 008
- 220420s2021 nz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.2147/OPTH.S346968 $2 doi
- 035 __
- $a (PubMed)34983999
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a nz
- 100 1_
- $a Fus, Martin $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic $1 https://orcid.org/0000000332454544
- 245 10
- $a Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens / $c M. Fus, S. Pitrova
- 520 9_
- $a Purpose: The aim of this study was to develop software for the universal objective evaluation of factors influencing intraocular correction of astigmatism, such as decentration, tilt, axial position and angular orientation the toric intraocular lens (IOL). Patients and Methods: Software was developed using the MS Visual Studio environment. The analysis was presented using images of 67 eyes with an implanted IOLs of the SN6ATx model series. Decentration and angular position of the lens were obtained from images of the anterior segment of the eye, using a Visucam unit. Tilt was measured on tomographic images from OCT Avanti (in meridian of highest tilt and perpendicular meridian) and preoperative biometry parameters of eye (axial length, anterior chamber depth - ACD, ocular lens thickness - LT, limbus diameter and mean keratometry value) including postoperative anterior chamber depth (pACD) were measured using Lenstar LS900. Results: Applying the software methodology to the evaluation of individual toric IOL parameters, the following results were obtained: mean decentration 0.25 ± 0.17 mm which was observed in 61.19% of eyes, mean misalignment to the planned axis equal to 3.8 ± 3.6 degrees, mean highest inclination equal to 3.7 ± 1.2 degrees and mean difference of pACD and ACD was equal to 1.46 ± 0.31 mm. There was only a weak nonsignificant correlation between preoperative ACD versus decentration and tilt of IOL or a weak significant correlation between preoperative LT and both decentration and misalignment of IOL. Conclusion: The use of the presented methodology for determining the positional parameters of the toric IOL provided comparable results with the results of recent studies. Software design can be considered as a suitable alternative to previously published techniques, with the significant advantage of the possibility of using universal input images, their graphical editing and especially the possibility of comprehensive analysis of all parameters.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Pitrova, Sarka $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
- 773 0_
- $w MED00165196 $t Clinical ophthalmology (Auckland, N.Z.) $x 1177-5467 $g Roč. 15, č. - (2021), s. 4755-4761
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34983999 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20220420 $b ABA008
- 991 __
- $a 20220425131826 $b ABA008
- 999 __
- $a ind $b bmc $g 1784590 $s 1161631
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 15 $c - $d 4755-4761 $e 20211219 $i 1177-5467 $m Clinical ophthalmology $n Clin Ophthalmol $x MED00165196
- LZP __
- $a Pubmed-20220420