Detecting perturbations of a radiation field inside a head-sized phantom exposed to therapeutic carbon-ion beams through charged-fragment tracking
L. Ghesquière-Diérickx, R. Félix-Bautista, A. Schlechter, L. Kelleter, M. Reimold, G. Echner, P. Soukup, O. Jäkel, T. Gehrke, M. Martišíková
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
Grantová podpora
426970603
Deutsche Forschungsgemeinschaft
PubMed
35073413
DOI
10.1002/mp.15480
Knihovny.cz E-zdroje
- MeSH
- celková dávka radioterapie MeSH
- fantomy radiodiagnostické MeSH
- ionty MeSH
- lidé MeSH
- metoda Monte Carlo MeSH
- radiometrie MeSH
- radioterapie těžkými ionty * metody MeSH
- uhlík * terapeutické užití MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Noninvasive methods to monitor carbon-ion beams in patients are desired to fully exploit the advantages of carbon-ion radiotherapy. Prompt secondary ions produced in nuclear fragmentations of carbon ions are of particular interest for monitoring purposes as they can escape the patient and thus be detected and tracked to measure the radiation field in the irradiated object. This study aims to evaluate the performance of secondary-ion tracking to detect, visualize, and localize an internal air cavity used to mimic inter-fractional changes in the patient anatomy at different depths along the beam axis. METHODS: In this work, a homogeneous head phantom was irradiated with a realistic carbon-ion treatment plan with a typical prescribed fraction dose of 3 Gy(RBE). Secondary ions were detected by a mini-tracker with an active area of 2 cm2 , based on the Timepix3 semiconductor pixel detector technology. The mini-tracker was placed 120 mm behind the center of the target at an angle of 30 degrees with respect to the beam axis. To assess the performance of the developed method, a 2-mm thick air cavity was inserted in the head phantom at several depths: in front of as well as at the entrance, in the middle, and at the distal end of the target volume. Different reconstruction methods of secondary-ion emission profile were studied using the FLUKA Monte Carlo simulation package. The perturbations in the emission profiles caused by the air cavity were analyzed to detect the presence of the air cavity and localize its position. RESULTS: The perturbations in the radiation field mimicked by the 2-mm thick cavity were found to be significant. A detection significance of at least three standard deviations in terms of spatial distribution of the measured tracks was found for all investigated cavity depths, while the highest significance (six standard deviations) was obtained when the cavity was located upstream of the tumor. For a tracker with an eight-fold sensitive area, the detection significance rose to at least nine standard deviations and up to 17 standard deviations, respectively. The cavity could be detected at all depths and its position measured within 6.5 ± 1.4 mm, which is sufficient for the targeted clinical performance of 10 mm. CONCLUSION: The presented systematic study concerning the detection and localization of small inter-fractional structure changes in a realistic clinical setting demonstrates that secondary ions carry a large amount of information on the internal structure of the irradiated object and are thus attractive to be further studied for noninvasive monitoring of carbon-ion treatments.
Department of Medical Physics in Radiation Oncology German Cancer Research Center Heidelberg Germany
Department of Radiation Oncology Heidelberg University Hospital Heidelberg Germany
Department of Research and Development ADVACAM s r o Prague Czech Republic
Faculty of Physics and Astronomy Heidelberg University Heidelberg Germany
Heidelberg Institute for Radiation Oncology Heidelberg Germany
Heidelberg Ion Beam Therapy Center Heidelberg Germany
Helmholtz Zentrum Dresden Rossendorf Dresden Germany
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22010893
- 003
- CZ-PrNML
- 005
- 20220506130109.0
- 007
- ta
- 008
- 220425s2022 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/mp.15480 $2 doi
- 035 __
- $a (PubMed)35073413
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Ghesquière-Diérickx, Laura $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Medical Faculty, Heidelberg University, Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany $1 https://orcid.org/0000000303526887
- 245 10
- $a Detecting perturbations of a radiation field inside a head-sized phantom exposed to therapeutic carbon-ion beams through charged-fragment tracking / $c L. Ghesquière-Diérickx, R. Félix-Bautista, A. Schlechter, L. Kelleter, M. Reimold, G. Echner, P. Soukup, O. Jäkel, T. Gehrke, M. Martišíková
- 520 9_
- $a PURPOSE: Noninvasive methods to monitor carbon-ion beams in patients are desired to fully exploit the advantages of carbon-ion radiotherapy. Prompt secondary ions produced in nuclear fragmentations of carbon ions are of particular interest for monitoring purposes as they can escape the patient and thus be detected and tracked to measure the radiation field in the irradiated object. This study aims to evaluate the performance of secondary-ion tracking to detect, visualize, and localize an internal air cavity used to mimic inter-fractional changes in the patient anatomy at different depths along the beam axis. METHODS: In this work, a homogeneous head phantom was irradiated with a realistic carbon-ion treatment plan with a typical prescribed fraction dose of 3 Gy(RBE). Secondary ions were detected by a mini-tracker with an active area of 2 cm2 , based on the Timepix3 semiconductor pixel detector technology. The mini-tracker was placed 120 mm behind the center of the target at an angle of 30 degrees with respect to the beam axis. To assess the performance of the developed method, a 2-mm thick air cavity was inserted in the head phantom at several depths: in front of as well as at the entrance, in the middle, and at the distal end of the target volume. Different reconstruction methods of secondary-ion emission profile were studied using the FLUKA Monte Carlo simulation package. The perturbations in the emission profiles caused by the air cavity were analyzed to detect the presence of the air cavity and localize its position. RESULTS: The perturbations in the radiation field mimicked by the 2-mm thick cavity were found to be significant. A detection significance of at least three standard deviations in terms of spatial distribution of the measured tracks was found for all investigated cavity depths, while the highest significance (six standard deviations) was obtained when the cavity was located upstream of the tumor. For a tracker with an eight-fold sensitive area, the detection significance rose to at least nine standard deviations and up to 17 standard deviations, respectively. The cavity could be detected at all depths and its position measured within 6.5 ± 1.4 mm, which is sufficient for the targeted clinical performance of 10 mm. CONCLUSION: The presented systematic study concerning the detection and localization of small inter-fractional structure changes in a realistic clinical setting demonstrates that secondary ions carry a large amount of information on the internal structure of the irradiated object and are thus attractive to be further studied for noninvasive monitoring of carbon-ion treatments.
- 650 12
- $a uhlík $x terapeutické užití $7 D002244
- 650 12
- $a radioterapie těžkými ionty $x metody $7 D063193
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a ionty $7 D007477
- 650 _2
- $a metoda Monte Carlo $7 D009010
- 650 _2
- $a fantomy radiodiagnostické $7 D019047
- 650 _2
- $a radiometrie $7 D011874
- 650 _2
- $a celková dávka radioterapie $7 D011879
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Félix-Bautista, Renato $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany $u Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
- 700 1_
- $a Schlechter, Annika $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany $u Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
- 700 1_
- $a Kelleter, Laurent $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany $1 https://orcid.org/0000000343469741
- 700 1_
- $a Reimold, Marvin $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany $u Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany $u Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany $u Technische Universität Dresden, Dresden, Germany
- 700 1_
- $a Echner, Gernot $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany
- 700 1_
- $a Soukup, Pavel $u Department of Research and Development, ADVACAM s.r.o., Prague, Czech Republic
- 700 1_
- $a Jäkel, Oliver $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany $u Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg, Germany
- 700 1_
- $a Gehrke, Tim $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany $u Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany $1 https://orcid.org/0000000260058576
- 700 1_
- $a Martišíková, Maria $u Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany $u Heidelberg Institute for Radiation Oncology (HIRO), National Center for Research in Radiation Oncology (NCRO), Heidelberg, Germany
- 773 0_
- $w MED00003245 $t Medical physics $x 2473-4209 $g Roč. 49, č. 3 (2022), s. 1776-1792
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35073413 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220425 $b ABA008
- 991 __
- $a 20220506130101 $b ABA008
- 999 __
- $a ok $b bmc $g 1788827 $s 1162091
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 49 $c 3 $d 1776-1792 $e 20220207 $i 2473-4209 $m Medical physics $n Med Phys $x MED00003245
- GRA __
- $a 426970603 $p Deutsche Forschungsgemeinschaft
- LZP __
- $a Pubmed-20220425