-
Je něco špatně v tomto záznamu ?
Analyses of the Tympanic Membrane Impulse Response Measured with High-Speed Holography
H. Tang, P. Psota, JJ. Rosowski, C. Furlong, JT. Cheng
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, Research Support, N.I.H., Extramural
Grantová podpora
R01 DC016079
NIDCD NIH HHS - United States
- MeSH
- akustická stimulace MeSH
- holografie * MeSH
- membrana tympani * diagnostické zobrazování MeSH
- střední ucho MeSH
- vibrace MeSH
- zvuk MeSH
- Publikační typ
- časopisecké články MeSH
- Research Support, N.I.H., Extramural MeSH
The Tympanic Membrane (TM) transforms acoustic energy to ossicular vibration. The shape and the displacement of the TM play an important role in this process. We developed a High-speed Digital Holography (HDH) system to measure the shape and transient displacements of the TM induced by acoustic clicks. The displacements were further normalized by the measured shape to derive surface normal displacements at over 100,000 points on the TM surface. Frequency and impulse response analyses were performed at each TM point, which enable us to describe 2D surface maps of four new TM mechanical parameters. From frequency domain analyses, we describe the (i) dominant frequencies of the displacement per sound pressure based on Frequency Response Function (FRF) at each surface point. From time domain analyses, we describe the (ii) rising time, (iii) exponential decay time, and the (iv) root-mean-square (rms) displacement of the TM based on Impulse Response Function (IRF) at each surface point. The resultant 2D maps show that a majority of the TM surface has a dominant frequency of around 1.5 kHz. The rising times suggest that much of the TM surface is set into motion within 50 μs of an impulsive stimulus. The maps of the exponential decay time of the IRF illustrate spatial variations in damping, the least known TM mechanical property. The damping ratios at locations with varied dominant frequencies are quantified and compared.
Department of Otolaryngology Head and Neck Surgery Harvard Medical School Boston MA United States
Eaton Peabody Laboratory Massachusetts Eye and Ear Infirmary Boston MA United States
Mechanical Engineering Department Worcester Polytechnic Institute Worcester MA United States
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22012144
- 003
- CZ-PrNML
- 005
- 20220506125927.0
- 007
- ta
- 008
- 220425s2021 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.heares.2021.108335 $2 doi
- 035 __
- $a (PubMed)34450569
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Tang, H $u Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester Polytechnic Institute, Worcester, MA United States; Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA United States; Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States. Electronic address: htang3@wpi.edu
- 245 10
- $a Analyses of the Tympanic Membrane Impulse Response Measured with High-Speed Holography / $c H. Tang, P. Psota, JJ. Rosowski, C. Furlong, JT. Cheng
- 520 9_
- $a The Tympanic Membrane (TM) transforms acoustic energy to ossicular vibration. The shape and the displacement of the TM play an important role in this process. We developed a High-speed Digital Holography (HDH) system to measure the shape and transient displacements of the TM induced by acoustic clicks. The displacements were further normalized by the measured shape to derive surface normal displacements at over 100,000 points on the TM surface. Frequency and impulse response analyses were performed at each TM point, which enable us to describe 2D surface maps of four new TM mechanical parameters. From frequency domain analyses, we describe the (i) dominant frequencies of the displacement per sound pressure based on Frequency Response Function (FRF) at each surface point. From time domain analyses, we describe the (ii) rising time, (iii) exponential decay time, and the (iv) root-mean-square (rms) displacement of the TM based on Impulse Response Function (IRF) at each surface point. The resultant 2D maps show that a majority of the TM surface has a dominant frequency of around 1.5 kHz. The rising times suggest that much of the TM surface is set into motion within 50 μs of an impulsive stimulus. The maps of the exponential decay time of the IRF illustrate spatial variations in damping, the least known TM mechanical property. The damping ratios at locations with varied dominant frequencies are quantified and compared.
- 650 _2
- $a akustická stimulace $7 D000161
- 650 _2
- $a střední ucho $7 D004432
- 650 12
- $a holografie $7 D006696
- 650 _2
- $a zvuk $7 D013016
- 650 12
- $a membrana tympani $x diagnostické zobrazování $7 D014432
- 650 _2
- $a vibrace $7 D014732
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a Research Support, N.I.H., Extramural $7 D052061
- 700 1_
- $a Psota, P $u Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic
- 700 1_
- $a Rosowski, J J $u Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
- 700 1_
- $a Furlong, C $u Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester Polytechnic Institute, Worcester, MA United States; Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA United States; Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
- 700 1_
- $a Cheng, J T $u Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
- 773 0_
- $w MED00002002 $t Hearing research $x 1878-5891 $g Roč. 410, č. - (2021), s. 108335
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34450569 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220425 $b ABA008
- 991 __
- $a 20220506125920 $b ABA008
- 999 __
- $a ok $b bmc $g 1789648 $s 1163345
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 410 $c - $d 108335 $e 20210811 $i 1878-5891 $m Hearing research $n Hear Res $x MED00002002
- GRA __
- $a R01 DC016079 $p NIDCD NIH HHS $2 United States
- LZP __
- $a Pubmed-20220425