• Je něco špatně v tomto záznamu ?

Analyses of the Tympanic Membrane Impulse Response Measured with High-Speed Holography

H. Tang, P. Psota, JJ. Rosowski, C. Furlong, JT. Cheng

. 2021 ; 410 (-) : 108335. [pub] 20210811

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, Research Support, N.I.H., Extramural

Perzistentní odkaz   https://www.medvik.cz/link/bmc22012144

Grantová podpora
R01 DC016079 NIDCD NIH HHS - United States

The Tympanic Membrane (TM) transforms acoustic energy to ossicular vibration. The shape and the displacement of the TM play an important role in this process. We developed a High-speed Digital Holography (HDH) system to measure the shape and transient displacements of the TM induced by acoustic clicks. The displacements were further normalized by the measured shape to derive surface normal displacements at over 100,000 points on the TM surface. Frequency and impulse response analyses were performed at each TM point, which enable us to describe 2D surface maps of four new TM mechanical parameters. From frequency domain analyses, we describe the (i) dominant frequencies of the displacement per sound pressure based on Frequency Response Function (FRF) at each surface point. From time domain analyses, we describe the (ii) rising time, (iii) exponential decay time, and the (iv) root-mean-square (rms) displacement of the TM based on Impulse Response Function (IRF) at each surface point. The resultant 2D maps show that a majority of the TM surface has a dominant frequency of around 1.5 kHz. The rising times suggest that much of the TM surface is set into motion within 50 μs of an impulsive stimulus. The maps of the exponential decay time of the IRF illustrate spatial variations in damping, the least known TM mechanical property. The damping ratios at locations with varied dominant frequencies are quantified and compared.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22012144
003      
CZ-PrNML
005      
20220506125927.0
007      
ta
008      
220425s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.heares.2021.108335 $2 doi
035    __
$a (PubMed)34450569
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Tang, H $u Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester Polytechnic Institute, Worcester, MA United States; Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA United States; Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States. Electronic address: htang3@wpi.edu
245    10
$a Analyses of the Tympanic Membrane Impulse Response Measured with High-Speed Holography / $c H. Tang, P. Psota, JJ. Rosowski, C. Furlong, JT. Cheng
520    9_
$a The Tympanic Membrane (TM) transforms acoustic energy to ossicular vibration. The shape and the displacement of the TM play an important role in this process. We developed a High-speed Digital Holography (HDH) system to measure the shape and transient displacements of the TM induced by acoustic clicks. The displacements were further normalized by the measured shape to derive surface normal displacements at over 100,000 points on the TM surface. Frequency and impulse response analyses were performed at each TM point, which enable us to describe 2D surface maps of four new TM mechanical parameters. From frequency domain analyses, we describe the (i) dominant frequencies of the displacement per sound pressure based on Frequency Response Function (FRF) at each surface point. From time domain analyses, we describe the (ii) rising time, (iii) exponential decay time, and the (iv) root-mean-square (rms) displacement of the TM based on Impulse Response Function (IRF) at each surface point. The resultant 2D maps show that a majority of the TM surface has a dominant frequency of around 1.5 kHz. The rising times suggest that much of the TM surface is set into motion within 50 μs of an impulsive stimulus. The maps of the exponential decay time of the IRF illustrate spatial variations in damping, the least known TM mechanical property. The damping ratios at locations with varied dominant frequencies are quantified and compared.
650    _2
$a akustická stimulace $7 D000161
650    _2
$a střední ucho $7 D004432
650    12
$a holografie $7 D006696
650    _2
$a zvuk $7 D013016
650    12
$a membrana tympani $x diagnostické zobrazování $7 D014432
650    _2
$a vibrace $7 D014732
655    _2
$a časopisecké články $7 D016428
655    _2
$a Research Support, N.I.H., Extramural $7 D052061
700    1_
$a Psota, P $u Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic
700    1_
$a Rosowski, J J $u Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
700    1_
$a Furlong, C $u Center for Holographic Studies and Laser Micro-mechaTronics (CHSLT), Worcester Polytechnic Institute, Worcester, MA United States; Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA United States; Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
700    1_
$a Cheng, J T $u Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA United States; Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Boston, MA, United States
773    0_
$w MED00002002 $t Hearing research $x 1878-5891 $g Roč. 410, č. - (2021), s. 108335
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34450569 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220425 $b ABA008
991    __
$a 20220506125920 $b ABA008
999    __
$a ok $b bmc $g 1789648 $s 1163345
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 410 $c - $d 108335 $e 20210811 $i 1878-5891 $m Hearing research $n Hear Res $x MED00002002
GRA    __
$a R01 DC016079 $p NIDCD NIH HHS $2 United States
LZP    __
$a Pubmed-20220425

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...