Changes of intraocular lens position induced by Nd:YAG capsulotomy

M. Fus, S. Pitrova, K. Maresova, J. Lestak

. 2022 ; 166 (2) : 211-216. [pub] 20210312

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22014554

AIMS: The aim of this study was to evaluate the changes in IOL position (axial shift, tilt and decentration) in the capsular bag after Nd:YAG laser capsulotomy and to create a user-friendly software that is optimized for the output of available imaging technology, then verify the relationship between the biometric parameters of the eye and the extent of changes in the IOL position. PATIENTS AND METHODS: The study included 35 artephakic eyes that underwent laser capsulotomy. Before and at least one hour after capsulotomy, all patients underwent the following assessments: optical biometry (Lenstar LS900), OCT with anterior segment module (Optovue Avanti) and IOL photography in infrared mode using reference unit (Verion). The original software solution was designed for the graphical evaluation of the differences between centering, axial displacement and tilt of IOL. Changes in IOL position were evaluated as simple differences before and after the laser procedure and as differences in absolute values (abs). RESULTS: The following results show the average differences in IOL position: ACD=0.02±0.23 mm (abs=0.11±0.20 mm), IOL decentration in x-axis = -0.001±0.091 mm (abs=0.065±0.063 mm), IOL decentration in y-axis =0.012±0.119 mm (abs=0.048±0.53 mm), tilt in horizontal plane TILT-H=0.11±0.83° (abs=0.51±0.66°) and tilt in vertical plane TILT-V = -0.14±0.49° (abs=0.26±0.44°). All changes were insignificant (P>>0.05). In total, 74.29% of IOLs showed a hypermetropic shift. A moderate positive correlation was found between the absolute differences in horizontal tilt and keratometry (r=0.45). Relationship with other changes and parameters were weak. CONCLUSION: In conclusion, the use of the original software solution developed by the authors showed that changes in IOL centering, axial displacement and tilt occur after Nd:YAG capsulotomy, but average differences were insignificant. In almost 3/4 cases, there was a hypermetropic axial displacement of the IOL.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22014554
003      
CZ-PrNML
005      
20230308094433.0
007      
ta
008      
220602s2022 xr a f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2021.014 $2 doi
035    __
$a (PubMed)33724262
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Fůs, Martin $u Eye Clinic JL FBMI CVUT Prague, Czech Republic $u Faculty of Biomedical Engineering, CVTU in Prague, Czech Republic $7 xx0227865
245    10
$a Changes of intraocular lens position induced by Nd:YAG capsulotomy / $c M. Fus, S. Pitrova, K. Maresova, J. Lestak
520    9_
$a AIMS: The aim of this study was to evaluate the changes in IOL position (axial shift, tilt and decentration) in the capsular bag after Nd:YAG laser capsulotomy and to create a user-friendly software that is optimized for the output of available imaging technology, then verify the relationship between the biometric parameters of the eye and the extent of changes in the IOL position. PATIENTS AND METHODS: The study included 35 artephakic eyes that underwent laser capsulotomy. Before and at least one hour after capsulotomy, all patients underwent the following assessments: optical biometry (Lenstar LS900), OCT with anterior segment module (Optovue Avanti) and IOL photography in infrared mode using reference unit (Verion). The original software solution was designed for the graphical evaluation of the differences between centering, axial displacement and tilt of IOL. Changes in IOL position were evaluated as simple differences before and after the laser procedure and as differences in absolute values (abs). RESULTS: The following results show the average differences in IOL position: ACD=0.02±0.23 mm (abs=0.11±0.20 mm), IOL decentration in x-axis = -0.001±0.091 mm (abs=0.065±0.063 mm), IOL decentration in y-axis =0.012±0.119 mm (abs=0.048±0.53 mm), tilt in horizontal plane TILT-H=0.11±0.83° (abs=0.51±0.66°) and tilt in vertical plane TILT-V = -0.14±0.49° (abs=0.26±0.44°). All changes were insignificant (P>>0.05). In total, 74.29% of IOLs showed a hypermetropic shift. A moderate positive correlation was found between the absolute differences in horizontal tilt and keratometry (r=0.45). Relationship with other changes and parameters were weak. CONCLUSION: In conclusion, the use of the original software solution developed by the authors showed that changes in IOL centering, axial displacement and tilt occur after Nd:YAG capsulotomy, but average differences were insignificant. In almost 3/4 cases, there was a hypermetropic axial displacement of the IOL.
650    _2
$a lidé $7 D006801
650    12
$a laserová terapie $7 D053685
650    _2
$a implantace nitrooční čočky $x metody $7 D019654
650    12
$a nitrooční čočky $7 D007910
650    12
$a fakoemulzifikace $7 D018918
655    _2
$a časopisecké články $7 D016428
700    1_
$a Pitrová, Šárka, $u Eye Clinic JL FBMI CVUT Prague, Czech Republic $u Faculty of Biomedical Engineering, CVTU in Prague, Czech Republic $d 1947- $7 mzk2006348964
700    1_
$a Marešová, Klára $u Department of Ophthalmology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, Czech Republic $7 nlk20060174069
700    1_
$a Lešták, Ján, $u Eye Clinic JL FBMI CVUT Prague, Czech Republic $u Faculty of Biomedical Engineering, CVTU in Prague, Czech Republic $d 1955- $7 xx0057880
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $x 1213-8118 $g Roč. 166, č. 2 (2022), s. 211-216
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33724262 $y Pubmed
910    __
$a ABA008 $b A 1502 $c 958 $y p $z 0
990    __
$a 20220602 $b ABA008
991    __
$a 20230308094428 $b ABA008
999    __
$a ok $b bmc $g 1824809 $s 1165775
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 166 $c 2 $d 211-216 $e 20210312 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK198 $a Pubmed-20220602

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...