Changes of intraocular lens position induced by Nd:YAG capsulotomy
M. Fus, S. Pitrova, K. Maresova, J. Lestak
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
Medline Complete (EBSCOhost)
od 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
33724262
DOI
10.5507/bp.2021.014
Knihovny.cz E-zdroje
- MeSH
- fakoemulzifikace * MeSH
- implantace nitrooční čočky metody MeSH
- laserová terapie * MeSH
- lidé MeSH
- nitrooční čočky * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: The aim of this study was to evaluate the changes in IOL position (axial shift, tilt and decentration) in the capsular bag after Nd:YAG laser capsulotomy and to create a user-friendly software that is optimized for the output of available imaging technology, then verify the relationship between the biometric parameters of the eye and the extent of changes in the IOL position. PATIENTS AND METHODS: The study included 35 artephakic eyes that underwent laser capsulotomy. Before and at least one hour after capsulotomy, all patients underwent the following assessments: optical biometry (Lenstar LS900), OCT with anterior segment module (Optovue Avanti) and IOL photography in infrared mode using reference unit (Verion). The original software solution was designed for the graphical evaluation of the differences between centering, axial displacement and tilt of IOL. Changes in IOL position were evaluated as simple differences before and after the laser procedure and as differences in absolute values (abs). RESULTS: The following results show the average differences in IOL position: ACD=0.02±0.23 mm (abs=0.11±0.20 mm), IOL decentration in x-axis = -0.001±0.091 mm (abs=0.065±0.063 mm), IOL decentration in y-axis =0.012±0.119 mm (abs=0.048±0.53 mm), tilt in horizontal plane TILT-H=0.11±0.83° (abs=0.51±0.66°) and tilt in vertical plane TILT-V = -0.14±0.49° (abs=0.26±0.44°). All changes were insignificant (P>>0.05). In total, 74.29% of IOLs showed a hypermetropic shift. A moderate positive correlation was found between the absolute differences in horizontal tilt and keratometry (r=0.45). Relationship with other changes and parameters were weak. CONCLUSION: In conclusion, the use of the original software solution developed by the authors showed that changes in IOL centering, axial displacement and tilt occur after Nd:YAG capsulotomy, but average differences were insignificant. In almost 3/4 cases, there was a hypermetropic axial displacement of the IOL.
Eye Clinic JL FBMI CVUT Prague Czech Republic
Faculty of Biomedical Engineering CVTU Prague Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22014554
- 003
- CZ-PrNML
- 005
- 20230308094433.0
- 007
- ta
- 008
- 220602s2022 xr a f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2021.014 $2 doi
- 035 __
- $a (PubMed)33724262
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Fůs, Martin $u Eye Clinic JL FBMI CVUT Prague, Czech Republic $u Faculty of Biomedical Engineering, CVTU in Prague, Czech Republic $7 xx0227865
- 245 10
- $a Changes of intraocular lens position induced by Nd:YAG capsulotomy / $c M. Fus, S. Pitrova, K. Maresova, J. Lestak
- 520 9_
- $a AIMS: The aim of this study was to evaluate the changes in IOL position (axial shift, tilt and decentration) in the capsular bag after Nd:YAG laser capsulotomy and to create a user-friendly software that is optimized for the output of available imaging technology, then verify the relationship between the biometric parameters of the eye and the extent of changes in the IOL position. PATIENTS AND METHODS: The study included 35 artephakic eyes that underwent laser capsulotomy. Before and at least one hour after capsulotomy, all patients underwent the following assessments: optical biometry (Lenstar LS900), OCT with anterior segment module (Optovue Avanti) and IOL photography in infrared mode using reference unit (Verion). The original software solution was designed for the graphical evaluation of the differences between centering, axial displacement and tilt of IOL. Changes in IOL position were evaluated as simple differences before and after the laser procedure and as differences in absolute values (abs). RESULTS: The following results show the average differences in IOL position: ACD=0.02±0.23 mm (abs=0.11±0.20 mm), IOL decentration in x-axis = -0.001±0.091 mm (abs=0.065±0.063 mm), IOL decentration in y-axis =0.012±0.119 mm (abs=0.048±0.53 mm), tilt in horizontal plane TILT-H=0.11±0.83° (abs=0.51±0.66°) and tilt in vertical plane TILT-V = -0.14±0.49° (abs=0.26±0.44°). All changes were insignificant (P>>0.05). In total, 74.29% of IOLs showed a hypermetropic shift. A moderate positive correlation was found between the absolute differences in horizontal tilt and keratometry (r=0.45). Relationship with other changes and parameters were weak. CONCLUSION: In conclusion, the use of the original software solution developed by the authors showed that changes in IOL centering, axial displacement and tilt occur after Nd:YAG capsulotomy, but average differences were insignificant. In almost 3/4 cases, there was a hypermetropic axial displacement of the IOL.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a laserová terapie $7 D053685
- 650 _2
- $a implantace nitrooční čočky $x metody $7 D019654
- 650 12
- $a nitrooční čočky $7 D007910
- 650 12
- $a fakoemulzifikace $7 D018918
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Pitrová, Šárka, $u Eye Clinic JL FBMI CVUT Prague, Czech Republic $u Faculty of Biomedical Engineering, CVTU in Prague, Czech Republic $d 1947- $7 mzk2006348964
- 700 1_
- $a Marešová, Klára $u Department of Ophthalmology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, Czech Republic $7 nlk20060174069
- 700 1_
- $a Lešták, Ján, $u Eye Clinic JL FBMI CVUT Prague, Czech Republic $u Faculty of Biomedical Engineering, CVTU in Prague, Czech Republic $d 1955- $7 xx0057880
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $x 1213-8118 $g Roč. 166, č. 2 (2022), s. 211-216
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33724262 $y Pubmed
- 910 __
- $a ABA008 $b A 1502 $c 958 $y p $z 0
- 990 __
- $a 20220602 $b ABA008
- 991 __
- $a 20230308094428 $b ABA008
- 999 __
- $a ok $b bmc $g 1824809 $s 1165775
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 166 $c 2 $d 211-216 $e 20210312 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK198 $a Pubmed-20220602