Contactless Measurement of Integrity of Silicone Coating on Self-Expandable Esophageal Nitinol Stents

M. Kopeček, J. Záhora, A. Bezrouk

. 2022 ; 65 (1) : 18-24. [pub] -

Language English Country Czech Republic

Document type Journal Article

Grant support
PROGRES Q40-09 Univerzita Karlova v Praze
SVV-260397/2021 Univerzita Karlova v Praze

OBJECTIVES: A stent is a mesh tube inserted into a natural passage in the body to prevent disease induction. Self-expandable esophageal nitinol stents such as SX-ELLA Stent Esophageal HV (HV Stent Plus) can be indicated for palliation of malignant esophageal strictures, for the treatment of benign esophageal strictures that are refractory to standard therapy and for the treatment of esophago-respiratory fistulas. A silicone-stent coating is used for tumor in-growth prevention and esophago-respiratory fistula occlusion. The thickness of the stent and the overall integrity of the silicone coating of all wires indicate the overall mechanical properties of the esophageal stent and the resistance to external adverse events such as corrosion and mechanical and chemical resistance. METHODS: The polymer multicomponent epoxy resin - a mixture of Epon and Durcupan - was used as a method for robust sample stabilization. A cutting system using a thin water beam with a powder (Blue Line) was chosen as the best variant to obtain 6 samples for both-sided measurement (10 measuring sides). The optical microscopic reflective light method was used to examine wire crossing points in the sections. Fifty values were measured on either sample side for the internal, external and mesh thickness of the silicone stent layer. The wire crossing points were selected so that the silicone layer structure could be clearly seen, and the wires approached each other most closely. Only approximately 4 to 8 crossing points in each section could be measured when applying this approach. The resolution of the microscope and calibration (based on the camera used) was 0.677 μm/pixel. RESULTS: Additional data could be obtained on 8 planes. Two boundary samples were destroyed by the cutting process. Whole coating of the stent was around all mesh wires, especially in areas with higher mechanical stress (wire crossing). The minimum detectable and admissible value determined for all 3 measuring areas (internal, external, mesh) on the wire crossings was 6.77 μm, i.e., 10 pixels, based on the microscope resolution and manufacturer's methodology. The results were characterized by p < 0.001 for all 3 parameters. We tested opposite samples in each section to verify the section quality and data consistency. For the 4 areas, the data were significantly different, but the thickness differences were only on the order of units percent, so the measurements were not appreciably affected. We assume that the material cutting loss, making up 1-2 mm, contributed to the differences in the sections. CONCLUSION: We examined the overall integrity of the silicone coating of the esophageal stent. The method of HV stent anchoring in a polymeric bath followed by cutting with a waterjet and sample measurement under an optical microscope proved to be very simple and reliable. Sufficient thicknesses of the silicone layer on the wire cross sections were verified. The coated silicone layer thickness appeared to be significantly different along the stent from the proximal part to the distant part, presumably due to the manufacturing technology.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22016359
003      
CZ-PrNML
005      
20221014133145.0
007      
ta
008      
220714s2022 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14712/18059694.2022.11 $2 doi
035    __
$a (PubMed)35793504
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Kopeček, Martin $u Department of Medical Biophysics, Charles University, Faculty of Medicine in Hradec Králové, Hradec Králové, Czech Republic. kopecema@lfhk.cuni.cz $7 xx0256423
245    10
$a Contactless Measurement of Integrity of Silicone Coating on Self-Expandable Esophageal Nitinol Stents / $c M. Kopeček, J. Záhora, A. Bezrouk
520    9_
$a OBJECTIVES: A stent is a mesh tube inserted into a natural passage in the body to prevent disease induction. Self-expandable esophageal nitinol stents such as SX-ELLA Stent Esophageal HV (HV Stent Plus) can be indicated for palliation of malignant esophageal strictures, for the treatment of benign esophageal strictures that are refractory to standard therapy and for the treatment of esophago-respiratory fistulas. A silicone-stent coating is used for tumor in-growth prevention and esophago-respiratory fistula occlusion. The thickness of the stent and the overall integrity of the silicone coating of all wires indicate the overall mechanical properties of the esophageal stent and the resistance to external adverse events such as corrosion and mechanical and chemical resistance. METHODS: The polymer multicomponent epoxy resin - a mixture of Epon and Durcupan - was used as a method for robust sample stabilization. A cutting system using a thin water beam with a powder (Blue Line) was chosen as the best variant to obtain 6 samples for both-sided measurement (10 measuring sides). The optical microscopic reflective light method was used to examine wire crossing points in the sections. Fifty values were measured on either sample side for the internal, external and mesh thickness of the silicone stent layer. The wire crossing points were selected so that the silicone layer structure could be clearly seen, and the wires approached each other most closely. Only approximately 4 to 8 crossing points in each section could be measured when applying this approach. The resolution of the microscope and calibration (based on the camera used) was 0.677 μm/pixel. RESULTS: Additional data could be obtained on 8 planes. Two boundary samples were destroyed by the cutting process. Whole coating of the stent was around all mesh wires, especially in areas with higher mechanical stress (wire crossing). The minimum detectable and admissible value determined for all 3 measuring areas (internal, external, mesh) on the wire crossings was 6.77 μm, i.e., 10 pixels, based on the microscope resolution and manufacturer's methodology. The results were characterized by p < 0.001 for all 3 parameters. We tested opposite samples in each section to verify the section quality and data consistency. For the 4 areas, the data were significantly different, but the thickness differences were only on the order of units percent, so the measurements were not appreciably affected. We assume that the material cutting loss, making up 1-2 mm, contributed to the differences in the sections. CONCLUSION: We examined the overall integrity of the silicone coating of the esophageal stent. The method of HV stent anchoring in a polymeric bath followed by cutting with a waterjet and sample measurement under an optical microscope proved to be very simple and reliable. Sufficient thicknesses of the silicone layer on the wire cross sections were verified. The coated silicone layer thickness appeared to be significantly different along the stent from the proximal part to the distant part, presumably due to the manufacturing technology.
650    12
$a obstrukce dýchacích cest $7 D000402
650    _2
$a slitiny $7 D000497
650    _2
$a stenóza $7 D003251
650    _2
$a lidé $7 D006801
650    12
$a silikony $7 D012828
650    _2
$a stenty $7 D015607
655    _2
$a časopisecké články $7 D016428
700    1_
$a Záhora, Jiří $u Department of Medical Biophysics, Charles University, Faculty of Medicine in Hradec Králové, Hradec Králové, Czech Republic $7 xx0179375
700    1_
$a Bezrouk, Aleš $u Department of Medical Biophysics, Charles University, Faculty of Medicine in Hradec Králové, Hradec Králové, Czech Republic $7 xx0193795
773    0_
$w MED00010947 $t Acta Medica $x 1805-9694 $g Roč. 65, č. 1 (2022), s. 18-24
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35793504 $y Pubmed
910    __
$a ABA008 $b A 3077 $c 1072 $y p $z 0
990    __
$a 20220714 $b ABA008
991    __
$a 20221014133137 $b ABA008
999    __
$a ok $b bmc $g 1848312 $s 1167601
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 65 $c 1 $d 18-24 $e - $i 1805-9694 $m Acta Medica $n Acta Med. (Hradec Král.) $x MED00010947
GRA    __
$a PROGRES Q40-09 $p Univerzita Karlova v Praze
GRA    __
$a SVV-260397/2021 $p Univerzita Karlova v Praze
LZP    __
$b NLK138 $a Pubmed-20220714

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...