-
Something wrong with this record ?
Pulse Oximeter Performance during Rapid Desaturation
L. Horakova, K. Roubik
Language English Country Switzerland
Document type Journal Article
Grant support
SGS20/202/OHK4/3T/17
Czech Technical University in Prague
NLK
Directory of Open Access Journals
from 2001
PubMed Central
from 2003
Europe PubMed Central
from 2003
ProQuest Central
from 2001-01-01
Open Access Digital Library
from 2001-01-01
Open Access Digital Library
from 2003-01-01
Health & Medicine (ProQuest)
from 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2001
PubMed
35684858
DOI
10.3390/s22114236
Knihovny.cz E-resources
- MeSH
- Hypoxia diagnosis MeSH
- Oxygen * MeSH
- Humans MeSH
- Monitoring, Physiologic MeSH
- Oximetry * MeSH
- Reproducibility of Results MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
The reliability of pulse oximetry is crucial, especially in cases of rapid changes in body oxygenation. In order to evaluate the performance of pulse oximeters during rapidly developing short periods of concurrent hypoxemia and hypercapnia, 13 healthy volunteers underwent 3 breathing phases during outdoor experiments (39 phases in total), monitored simultaneously by five different pulse oximeters. A significant incongruity in values displayed by the tested pulse oximeters was observed, even when the accuracy declared by the manufacturers were considered. In 28.2% of breathing phases, the five used devices did not show any congruent values. The longest uninterrupted congruent period formed 74.4% of total recorded time. Moreover, the congruent periods were rarely observed during the critical desaturation phase of the experiment. The time difference between the moments when the first and the last pulse oximeter showed the typical study endpoint values of SpO2 85% and 75% was 32.1 ± 23.6 s and 24.7 ± 19.3 s, respectively. These results suggest that SpO2 might not be a reliable parameter as a study endpoint, or more importantly as a safety limit in outdoor experiments. In the design of future studies, more parameters and continuous clinical assessment should be included.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22018072
- 003
- CZ-PrNML
- 005
- 20220804134533.0
- 007
- ta
- 008
- 220720s2022 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s22114236 $2 doi
- 035 __
- $a (PubMed)35684858
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Horakova, Lenka $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic $1 https://orcid.org/0000000315108412 $7 xx0255519
- 245 10
- $a Pulse Oximeter Performance during Rapid Desaturation / $c L. Horakova, K. Roubik
- 520 9_
- $a The reliability of pulse oximetry is crucial, especially in cases of rapid changes in body oxygenation. In order to evaluate the performance of pulse oximeters during rapidly developing short periods of concurrent hypoxemia and hypercapnia, 13 healthy volunteers underwent 3 breathing phases during outdoor experiments (39 phases in total), monitored simultaneously by five different pulse oximeters. A significant incongruity in values displayed by the tested pulse oximeters was observed, even when the accuracy declared by the manufacturers were considered. In 28.2% of breathing phases, the five used devices did not show any congruent values. The longest uninterrupted congruent period formed 74.4% of total recorded time. Moreover, the congruent periods were rarely observed during the critical desaturation phase of the experiment. The time difference between the moments when the first and the last pulse oximeter showed the typical study endpoint values of SpO2 85% and 75% was 32.1 ± 23.6 s and 24.7 ± 19.3 s, respectively. These results suggest that SpO2 might not be a reliable parameter as a study endpoint, or more importantly as a safety limit in outdoor experiments. In the design of future studies, more parameters and continuous clinical assessment should be included.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hypoxie $x diagnóza $7 D000860
- 650 _2
- $a monitorování fyziologických funkcí $7 D008991
- 650 12
- $a oxymetrie $7 D010092
- 650 12
- $a kyslík $7 D010100
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Roubik, Karel $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic $1 https://orcid.org/0000000158136355
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 22, č. 11 (2022)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35684858 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804134527 $b ABA008
- 999 __
- $a ok $b bmc $g 1821909 $s 1169315
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 22 $c 11 $e 20220602 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- GRA __
- $a SGS20/202/OHK4/3T/17 $p Czech Technical University in Prague
- LZP __
- $a Pubmed-20220720