-
Something wrong with this record ?
Percutaneous Endoluminal Radiofrequency Ablation of Occluded Biliary Metal Stent in Malignancy Using Monopolar Technique: A Feasibility Study
T. Rohan, T. Andrasina, P. Matkulcik, V. Bernard, V. Valek
Language English Country United States
Document type Journal Article
Grant support
NU21-08-00561
Ministerstvo Zdravotnictví Ceské Republiky
NLK
ProQuest Central
from 1997-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2003-02-01 to 1 year ago
Nursing & Allied Health Database (ProQuest)
from 1997-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 1997-01-01 to 1 year ago
- MeSH
- Cholestasis * diagnostic imaging etiology surgery MeSH
- Catheter Ablation * methods MeSH
- Humans MeSH
- Bile Duct Neoplasms * surgery MeSH
- Radiofrequency Ablation * MeSH
- Retrospective Studies MeSH
- Stents adverse effects MeSH
- Feasibility Studies MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
PURPOSE: To prove feasibility and safety of percutaneous endoluminal radiofrequency ablation (eRFA) using a monopolar approach in treatment of occluded biliary stent in malignancy. MATERIALS AND METHODS: The study included 11 patients with occluded biliary metal stent that had been implanted due to malignant biliary obstruction. All underwent metal stent recanalization by percutaneous eRFA in monopolar setting. Sixteen eRFA procedures were performed under fluoroscopic guidance with an EndoHPB 8F radiofrequency ablation catheter. The effect of stent recanalization was assessed based upon change from pre- to post-procedural diameter of the patent lumen of the metal stent (Wilcoxon test), primary and secondary stent patency (compared by log-rank test), catheter-free period, and overall survival. Adverse events were evaluated according to Common Terminology Criteria for Adverse Events (CTCEA) 4.0. RESULTS: Recanalization of the metal stent by monopolar radiofrequency ablation was successful in all 11 patients. Diameter of the patent lumen of the stent significantly widened after the eRFA inside the stent (median 2 vs. 7 mm, p = 0.003). Grade 1 complications were observed in one-third of procedures. Median stent patency after recanalization by eRFA was non-inferior to primary metal stent patency (154 vs. 161 days, p = 0.27). Median catheter-free survival and overall survival after stent recanalization were 149 and 210 days, respectively. CONCLUSION: Endoluminal radiofrequency ablation in monopolar setting was shown to be a feasible and safe method for recanalization of occluded biliary metal stents. LEVEL OF EVIDENCE: Level 4, Case Series.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22018111
- 003
- CZ-PrNML
- 005
- 20220804134549.0
- 007
- ta
- 008
- 220720s2022 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00270-022-03097-z $2 doi
- 035 __
- $a (PubMed)35217890
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Rohan, Tomas $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Brno, 625 00, Czech Republic
- 245 10
- $a Percutaneous Endoluminal Radiofrequency Ablation of Occluded Biliary Metal Stent in Malignancy Using Monopolar Technique: A Feasibility Study / $c T. Rohan, T. Andrasina, P. Matkulcik, V. Bernard, V. Valek
- 520 9_
- $a PURPOSE: To prove feasibility and safety of percutaneous endoluminal radiofrequency ablation (eRFA) using a monopolar approach in treatment of occluded biliary stent in malignancy. MATERIALS AND METHODS: The study included 11 patients with occluded biliary metal stent that had been implanted due to malignant biliary obstruction. All underwent metal stent recanalization by percutaneous eRFA in monopolar setting. Sixteen eRFA procedures were performed under fluoroscopic guidance with an EndoHPB 8F radiofrequency ablation catheter. The effect of stent recanalization was assessed based upon change from pre- to post-procedural diameter of the patent lumen of the metal stent (Wilcoxon test), primary and secondary stent patency (compared by log-rank test), catheter-free period, and overall survival. Adverse events were evaluated according to Common Terminology Criteria for Adverse Events (CTCEA) 4.0. RESULTS: Recanalization of the metal stent by monopolar radiofrequency ablation was successful in all 11 patients. Diameter of the patent lumen of the stent significantly widened after the eRFA inside the stent (median 2 vs. 7 mm, p = 0.003). Grade 1 complications were observed in one-third of procedures. Median stent patency after recanalization by eRFA was non-inferior to primary metal stent patency (154 vs. 161 days, p = 0.27). Median catheter-free survival and overall survival after stent recanalization were 149 and 210 days, respectively. CONCLUSION: Endoluminal radiofrequency ablation in monopolar setting was shown to be a feasible and safe method for recanalization of occluded biliary metal stents. LEVEL OF EVIDENCE: Level 4, Case Series.
- 650 12
- $a nádory žlučových cest $x chirurgie $7 D001650
- 650 12
- $a katetrizační ablace $x metody $7 D017115
- 650 12
- $a cholestáza $x diagnostické zobrazování $x etiologie $x chirurgie $7 D002779
- 650 _2
- $a studie proveditelnosti $7 D005240
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a radiofrekvenční ablace $7 D000078703
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a stenty $x škodlivé účinky $7 D015607
- 650 _2
- $a výsledek terapie $7 D016896
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Andrasina, Tomas $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Brno, 625 00, Czech Republic. andrasina.tomas@fnbrno.cz $1 https://orcid.org/0000000157235175 $7 xx0074370
- 700 1_
- $a Matkulcik, Peter $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Brno, 625 00, Czech Republic
- 700 1_
- $a Bernard, Vladan $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno, 625 00, Czech Republic
- 700 1_
- $a Valek, Vlastimil $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Brno, 625 00, Czech Republic
- 773 0_
- $w MED00001056 $t Cardiovascular and interventional radiology $x 1432-086X $g Roč. 45, č. 6 (2022), s. 873-878
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35217890 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804134543 $b ABA008
- 999 __
- $a ok $b bmc $g 1821941 $s 1169354
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 45 $c 6 $d 873-878 $e 20220225 $i 1432-086X $m Cardiovascular and interventional radiology $n Cardiovasc Intervent Radiol $x MED00001056
- GRA __
- $a NU21-08-00561 $p Ministerstvo Zdravotnictví Ceské Republiky
- LZP __
- $a Pubmed-20220720