-
Je něco špatně v tomto záznamu ?
Comparable respiratory activity in attached and suspended human fibroblasts
L. Zdrazilova, H. Hansikova, E. Gnaiger
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2006
Free Medical Journals
od 2006
Public Library of Science (PLoS)
od 2006
PubMed Central
od 2006
Europe PubMed Central
od 2006
ProQuest Central
od 2006-12-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-10-01
Medline Complete (EBSCOhost)
od 2008-01-01
Nursing & Allied Health Database (ProQuest)
od 2006-12-01
Health & Medicine (ProQuest)
od 2006-12-01
Public Health Database (ProQuest)
od 2006-12-01
ROAD: Directory of Open Access Scholarly Resources
od 2006
- MeSH
- buněčné dýchání * fyziologie MeSH
- fibroblasty MeSH
- lidé MeSH
- oxidativní fosforylace * MeSH
- reprodukovatelnost výsledků MeSH
- spotřeba kyslíku fyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Measurement of oxygen consumption of cultured cells is widely used for diagnosis of mitochondrial diseases, drug testing, biotechnology, and toxicology. Fibroblasts are cultured in monolayers, but physiological measurements are carried out in suspended or attached cells. We address the question whether respiration differs in attached versus suspended cells using multiwell respirometry (Agilent Seahorse XF24) and high-resolution respirometry (Oroboros O2k), respectively. Respiration of human dermal fibroblasts measured in culture medium was baseline-corrected for residual oxygen consumption and expressed as oxygen flow per cell. No differences were observed between attached and suspended cells in ROUTINE respiration of living cells and LEAK respiration obtained after inhibition of ATP synthase by oligomycin. The electron transfer capacity was higher in the O2k than in the XF24. This could be explained by a limitation to two uncoupler titrations in the XF24 which led to an underestimation compared to multiple titration steps in the O2k. A quantitative evaluation of respiration measured via different platforms revealed that short-term suspension of fibroblasts did not affect respiratory activity and coupling control. Evaluation of results obtained by different platforms provides a test for reproducibility beyond repeatability. Repeatability and reproducibility are required for building a validated respirometric database.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22019232
- 003
- CZ-PrNML
- 005
- 20220804135443.0
- 007
- ta
- 008
- 220720s2022 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1371/journal.pone.0264496 $2 doi
- 035 __
- $a (PubMed)35239701
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Zdrazilova, Lucie $u Department of Pediatrics and Inherited Metabolic Disorders, First Faculty of Medicine, Charles University and General Hospital in Prague, Prague, Czechia $1 https://orcid.org/0000000281032498
- 245 10
- $a Comparable respiratory activity in attached and suspended human fibroblasts / $c L. Zdrazilova, H. Hansikova, E. Gnaiger
- 520 9_
- $a Measurement of oxygen consumption of cultured cells is widely used for diagnosis of mitochondrial diseases, drug testing, biotechnology, and toxicology. Fibroblasts are cultured in monolayers, but physiological measurements are carried out in suspended or attached cells. We address the question whether respiration differs in attached versus suspended cells using multiwell respirometry (Agilent Seahorse XF24) and high-resolution respirometry (Oroboros O2k), respectively. Respiration of human dermal fibroblasts measured in culture medium was baseline-corrected for residual oxygen consumption and expressed as oxygen flow per cell. No differences were observed between attached and suspended cells in ROUTINE respiration of living cells and LEAK respiration obtained after inhibition of ATP synthase by oligomycin. The electron transfer capacity was higher in the O2k than in the XF24. This could be explained by a limitation to two uncoupler titrations in the XF24 which led to an underestimation compared to multiple titration steps in the O2k. A quantitative evaluation of respiration measured via different platforms revealed that short-term suspension of fibroblasts did not affect respiratory activity and coupling control. Evaluation of results obtained by different platforms provides a test for reproducibility beyond repeatability. Repeatability and reproducibility are required for building a validated respirometric database.
- 650 12
- $a buněčné dýchání $x fyziologie $7 D019069
- 650 _2
- $a fibroblasty $7 D005347
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a oxidativní fosforylace $7 D010085
- 650 _2
- $a spotřeba kyslíku $x fyziologie $7 D010101
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Hansikova, Hana $u Department of Pediatrics and Inherited Metabolic Disorders, First Faculty of Medicine, Charles University and General Hospital in Prague, Prague, Czechia $1 https://orcid.org/000000022734225X $7 xx0064303
- 700 1_
- $a Gnaiger, Erich $u Oroboros Instruments, Innsbruck, Austria
- 773 0_
- $w MED00180950 $t PloS one $x 1932-6203 $g Roč. 17, č. 3 (2022), s. e0264496
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35239701 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804135437 $b ABA008
- 999 __
- $a ok $b bmc $g 1822712 $s 1170475
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 17 $c 3 $d e0264496 $e 20220303 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
- LZP __
- $a Pubmed-20220720