Assessment of left ventricular volumes and ejection fraction using ultra-low-dose thallium-201 SPECT on a CZT camera: a comparison with magnetic resonance imaging
M. Sala, V. Kincl, M. Kamínek, J. Vašina, J. Máchal, R. Panovský, V. Feitová, L. Opatřil, T. Holeček
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- funkce levé komory srdeční * MeSH
- jednofotonová emisní výpočetní tomografie * metody MeSH
- kadmium MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- radioizotopy thallia MeSH
- telur MeSH
- tepový objem MeSH
- zinek MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Cadmium-Zinc-Telluride (CZT) technology allows use of low activities of radiopharmaceuticals. The aim was to verify the values of left ventricular volume parameters, obtained via ultra-low-dose thallium Single Photon Emission Computed Tomography (SPECT) using a CZT camera. METHODS AND RESULTS: Forty-five patients referred for an assessment of myocardial perfusion or viability imaging were examined using CZT-SPECT and 1.5 T magnetic resonance (MRI) scanner. The ultra-low-dose protocol with 0.5 Mbq 201-Tl per kg of body weight was used. The values of end-systolic (ESV) and end-diastolic volumes (EDV), left ventricular ejection fraction (EF) and myocardial mass (MM) were assessed using both techniques. A very good correlation was found between the EF, ESV, and EDV values assessed with CZT-SPECT and cardiac magnetic resonance MRI; the Pearson coefficients were 0.86, 0.95, and 0.91, respectively. A moderate correlation was found for myocardial mass, r = 0.57. Compared to MRI, SPECT systematically overestimated ESV and MM, while it underestimates the EF, with P ≤ .001 in all cases. There was no difference in EDV estimation. CONCLUSIONS: Left ventricular volumes and ejection fraction assessed via ultra-low-dose CZT-SPECT showed very good correlation with the values obtained by MRI. A moderate correlation was found for myocardial mass.
Department of Medical Imaging St Anne ́s University Hospital Masaryk University Brno Czech Republic
Department of Nuclear Medicine Masaryk Memorial Cancer Center Brno Czech Republic
Department of Nuclear Medicine University Hospital Olomouc Palacký University Olomouc Czech Republic
Department of Pathological Physiology Masaryk University Brno Czech Republic
International Clinical Research Center St Anne ́s University Hospital Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22019436
- 003
- CZ-PrNML
- 005
- 20220804135644.0
- 007
- ta
- 008
- 220720s2022 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s12350-020-02161-w $2 doi
- 035 __
- $a (PubMed)32410056
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Sala, Marek $u Department of Internal Medicine/Cardiology, St. Anne ́s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic
- 245 10
- $a Assessment of left ventricular volumes and ejection fraction using ultra-low-dose thallium-201 SPECT on a CZT camera: a comparison with magnetic resonance imaging / $c M. Sala, V. Kincl, M. Kamínek, J. Vašina, J. Máchal, R. Panovský, V. Feitová, L. Opatřil, T. Holeček
- 520 9_
- $a BACKGROUND: Cadmium-Zinc-Telluride (CZT) technology allows use of low activities of radiopharmaceuticals. The aim was to verify the values of left ventricular volume parameters, obtained via ultra-low-dose thallium Single Photon Emission Computed Tomography (SPECT) using a CZT camera. METHODS AND RESULTS: Forty-five patients referred for an assessment of myocardial perfusion or viability imaging were examined using CZT-SPECT and 1.5 T magnetic resonance (MRI) scanner. The ultra-low-dose protocol with 0.5 Mbq 201-Tl per kg of body weight was used. The values of end-systolic (ESV) and end-diastolic volumes (EDV), left ventricular ejection fraction (EF) and myocardial mass (MM) were assessed using both techniques. A very good correlation was found between the EF, ESV, and EDV values assessed with CZT-SPECT and cardiac magnetic resonance MRI; the Pearson coefficients were 0.86, 0.95, and 0.91, respectively. A moderate correlation was found for myocardial mass, r = 0.57. Compared to MRI, SPECT systematically overestimated ESV and MM, while it underestimates the EF, with P ≤ .001 in all cases. There was no difference in EDV estimation. CONCLUSIONS: Left ventricular volumes and ejection fraction assessed via ultra-low-dose CZT-SPECT showed very good correlation with the values obtained by MRI. A moderate correlation was found for myocardial mass.
- 650 _2
- $a kadmium $7 D002104
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a magnetická rezonanční tomografie $x metody $7 D008279
- 650 _2
- $a tepový objem $7 D013318
- 650 _2
- $a telur $7 D013691
- 650 _2
- $a radioizotopy thallia $7 D013794
- 650 12
- $a jednofotonová emisní výpočetní tomografie $x metody $7 D015899
- 650 12
- $a funkce levé komory srdeční $7 D016277
- 650 _2
- $a zinek $7 D015032
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kincl, Vladimír $u Department of Internal Medicine/Cardiology, St. Anne ́s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic. vladimir.kincl@fnusa.cz $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic. vladimir.kincl@fnusa.cz
- 700 1_
- $a Kamínek, Milan $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic $u Department of Nuclear Medicine, University Hospital Olomouc, Palacký University, Olomouc, Czech Republic
- 700 1_
- $a Vašina, Jiří $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic $u Department of Nuclear Medicine, Masaryk Memorial Cancer Center, Brno, Czech Republic
- 700 1_
- $a Máchal, Jan $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic $u Department of Pathological Physiology, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Panovský, Roman $u Department of Internal Medicine/Cardiology, St. Anne ́s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic
- 700 1_
- $a Feitová, Věra $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic $u Department of Medical Imaging, St. Anne ́s University Hospital, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Opatřil, Lukáš $u Department of Internal Medicine/Cardiology, St. Anne ́s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic
- 700 1_
- $a Holeček, Tomáš $u International Clinical Research Center, St. Anne ́s University Hospital, Brno, Czech Republic $u Department of Medical Imaging, St. Anne ́s University Hospital, Masaryk University, Brno, Czech Republic
- 773 0_
- $w MED00002849 $t Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology $x 1532-6551 $g Roč. 29, č. 1 (2022), s. 181-187
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32410056 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804135638 $b ABA008
- 999 __
- $a ok $b bmc $g 1822859 $s 1170679
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 29 $c 1 $d 181-187 $e 20200514 $i 1532-6551 $m Journal of nuclear cardiology $n J Nucl Cardiol $x MED00002849
- LZP __
- $a Pubmed-20220720