Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Extremity compartment syndrome: A review with a focus on non-invasive methods of diagnosis

M. Novak, M. Penhaker, P. Raska, L. Pleva, M. Schmidt

. 2022 ; 10 (-) : 801586. [pub] 20220718

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc22023696

The article deals with an overview of acute extremity compartment syndrome with a focus on the option of non-invasive detection of the syndrome. Acute extremity compartment syndrome (ECS) is an urgent complication that occurs most often in fractures or high-energy injuries. There is still no reliable method for detecting ECS. The only objective measurement method used in clinical practice is an invasive measurement of intramuscular pressure (IMP). The purpose of this paper is to summarize the current state of research into non-invasive measurement methods that could allow simple and reliable continuous monitoring of patients at risk of developing ECS. Clinical trials are currently underway to verify the suitability of the most studied method, near-infrared spectroscopy (NIRS), which is a method for measuring the local oxygenation of muscle compartments. Less explored methods include the use of ultrasound, ultrasound elastography, bioimpedance measurements, and quantitative tissue hardness measurements. Finding a suitable method for continuous non-invasive monitoring of the syndrome would greatly improve the quality of care for patients at risk. ECS must be diagnosed quickly and accurately to prevent irreversible tissue damage that can occur within hours of syndrome onset and may even warrant amputation if neglected.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22023696
003      
CZ-PrNML
005      
20221031095100.0
007      
ta
008      
221010s2022 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3389/fbioe.2022.801586 $2 doi
035    __
$a (PubMed)35923576
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Novak, Martin $u Trauma Surgery Clinic, University Hospital Ostrava, Ostrava, Czechia
245    10
$a Extremity compartment syndrome: A review with a focus on non-invasive methods of diagnosis / $c M. Novak, M. Penhaker, P. Raska, L. Pleva, M. Schmidt
520    9_
$a The article deals with an overview of acute extremity compartment syndrome with a focus on the option of non-invasive detection of the syndrome. Acute extremity compartment syndrome (ECS) is an urgent complication that occurs most often in fractures or high-energy injuries. There is still no reliable method for detecting ECS. The only objective measurement method used in clinical practice is an invasive measurement of intramuscular pressure (IMP). The purpose of this paper is to summarize the current state of research into non-invasive measurement methods that could allow simple and reliable continuous monitoring of patients at risk of developing ECS. Clinical trials are currently underway to verify the suitability of the most studied method, near-infrared spectroscopy (NIRS), which is a method for measuring the local oxygenation of muscle compartments. Less explored methods include the use of ultrasound, ultrasound elastography, bioimpedance measurements, and quantitative tissue hardness measurements. Finding a suitable method for continuous non-invasive monitoring of the syndrome would greatly improve the quality of care for patients at risk. ECS must be diagnosed quickly and accurately to prevent irreversible tissue damage that can occur within hours of syndrome onset and may even warrant amputation if neglected.
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Penhaker, Marek $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, Ostrava, Czechia
700    1_
$a Raska, Pavel $u Department of Occupational and Process Safety, Faculty of Safety Engineering, VSB-Technical University of Ostrava, Ostrava, Czechia
700    1_
$a Pleva, Leopold $u Trauma Surgery Clinic, University Hospital Ostrava, Ostrava, Czechia
700    1_
$a Schmidt, Martin $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, Ostrava, Czechia
773    0_
$w MED00188064 $t Frontiers in bioengineering and biotechnology $x 2296-4185 $g Roč. 10, č. - (2022), s. 801586
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35923576 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20221010 $b ABA008
991    __
$a 20221031095058 $b ABA008
999    __
$a ind $b bmc $g 1853979 $s 1174984
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 10 $c - $d 801586 $e 20220718 $i 2296-4185 $m Frontiers in bioengineering and biotechnology $n Front Bioeng Biotechnol $x MED00188064
LZP    __
$a Pubmed-20221010

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...