The exactness of intraocular lens power calculation formulas for short eyes and correlation between method accuracy and eyeball axial length
W. Stopyra
Jazyk angličtina Země Česko
- Klíčová slova
- Hoffer Q formula,
- MeSH
- axiální délka oka MeSH
- biometrie * metody MeSH
- fakoemulzifikace MeSH
- hypermetropie MeSH
- implantace nitrooční čočky * MeSH
- lidé MeSH
- refrakce oka fyziologie MeSH
- refrakční vady * MeSH
- Check Tag
- lidé MeSH
Purpose: To compare the accuracy of intraocular lens power calculation formulas and to examine the correlation of this exactness with the axial length for eyes shorter than 22.00 mm Methods: The data of hyperopic patients who underwent uneventful phacoemulsification between October 2015 and June 2019 were reviewed. The intraocular lens power for each patient was calculated using 6 formulas (Holladay1, SRK/T, Hoffer Q, Holladay 2, Haigis and Barrett Universal II) before cataract surgery. Postoperative refraction was measured, and refractive prediction error was calculated 3 months after phacoemulsification. The correlation between axial length and absolute error was evaluated. Results: Fifty-six patients (62 eyes) whose ocular axial length ranged between 20.58 mm and 21.97 mm were included in the study. The Hoffer Q formula achieved the lowest mean absolute error of 0.09 (±0.08 D). A significant correlation for the Hoffer Q (ρ = -0.329, p = 0.009) and the SRK/T (ρ = 0.321, p = 0.011) formula was observed. Conclusions: 1. The Hoffer Q formula obtained the lowest absolute error and was recommended for intraocular lens power calculation for eyeballs with axial length shorter than 22.0 mm. 2. The correlation between axial length and absolute error is a factor which should be considered when calculating intraocular lens power.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22024114
- 003
- CZ-PrNML
- 005
- 20221207152922.0
- 007
- ta
- 008
- 221017s2022 xr cd f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.31348/2022/24 $2 doi
- 035 __
- $a (PubMed)36220363
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Stopyra, Wiktor $u MW med Eye Centre, Cracow, Poland
- 245 14
- $a The exactness of intraocular lens power calculation formulas for short eyes and correlation between method accuracy and eyeball axial length / $c W. Stopyra
- 520 9_
- $a Purpose: To compare the accuracy of intraocular lens power calculation formulas and to examine the correlation of this exactness with the axial length for eyes shorter than 22.00 mm Methods: The data of hyperopic patients who underwent uneventful phacoemulsification between October 2015 and June 2019 were reviewed. The intraocular lens power for each patient was calculated using 6 formulas (Holladay1, SRK/T, Hoffer Q, Holladay 2, Haigis and Barrett Universal II) before cataract surgery. Postoperative refraction was measured, and refractive prediction error was calculated 3 months after phacoemulsification. The correlation between axial length and absolute error was evaluated. Results: Fifty-six patients (62 eyes) whose ocular axial length ranged between 20.58 mm and 21.97 mm were included in the study. The Hoffer Q formula achieved the lowest mean absolute error of 0.09 (±0.08 D). A significant correlation for the Hoffer Q (ρ = -0.329, p = 0.009) and the SRK/T (ρ = 0.321, p = 0.011) formula was observed. Conclusions: 1. The Hoffer Q formula obtained the lowest absolute error and was recommended for intraocular lens power calculation for eyeballs with axial length shorter than 22.0 mm. 2. The correlation between axial length and absolute error is a factor which should be considered when calculating intraocular lens power.
- 650 17
- $a implantace nitrooční čočky $7 D019654 $2 czmesh
- 650 _7
- $a hypermetropie $7 D006956 $2 czmesh
- 650 _7
- $a fakoemulzifikace $7 D018918 $2 czmesh
- 650 _7
- $a axiální délka oka $7 D058452 $2 czmesh
- 650 17
- $a biometrie $x metody $7 D001699 $2 czmesh
- 650 _7
- $a refrakce oka $x fyziologie $7 D012029 $2 czmesh
- 650 _7
- $a lidé $7 D006801 $2 czmesh
- 650 17
- $a refrakční vady $7 D012030 $2 czmesh
- 653 00
- $a Hoffer Q formula
- 773 0_
- $w MED00010980 $t Česká a slovenská oftalmologie $x 1211-9059 $g Roč. 78, č. 5 (2022), s. 236-240
- 856 41
- $u https://www.prolekare.cz/casopisy/ceska-slovenska-oftalmologie/2022-5-2/the-exactness-of-intraocular-lens-power-calculation-formulas-for-short-eyes-and-correlation-between-method-accuracy-and-eyeball-axial-length-131896 $y plný text volně dostupný
- 910 __
- $a ABA008 $b A 202 $c 639 $y p $z 0
- 990 __
- $a 20221017 $b ABA008
- 991 __
- $a 20221207152917 $b ABA008
- 999 __
- $a ok $b bmc $g 1852122 $s 1175404
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 78 $c 5 $d 236-240 $i 1211-9059 $m Česká a slovenská oftalmologie $x MED00010980 $y 131896
- LZP __
- $c NLK108 $d 20221207 $b NLK111 $a Meditorial-20221017