. 2022 ; 78 (5) : 236-240.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc22024114

Purpose: To compare the accuracy of intraocular lens power calculation formulas and to examine the correlation of this exactness with the axial length for eyes shorter than 22.00 mm Methods: The data of hyperopic patients who underwent uneventful phacoemulsification between October 2015 and June 2019 were reviewed. The intraocular lens power for each patient was calculated using 6 formulas (Holladay1, SRK/T, Hoffer Q, Holladay 2, Haigis and Barrett Universal II) before cataract surgery. Postoperative refraction was measured, and refractive prediction error was calculated 3 months after phacoemulsification. The correlation between axial length and absolute error was evaluated. Results: Fifty-six patients (62 eyes) whose ocular axial length ranged between 20.58 mm and 21.97 mm were included in the study. The Hoffer Q formula achieved the lowest mean absolute error of 0.09 (±0.08 D). A significant correlation for the Hoffer Q (ρ = -0.329, p = 0.009) and the SRK/T (ρ = 0.321, p = 0.011) formula was observed. Conclusions: 1. The Hoffer Q formula obtained the lowest absolute error and was recommended for intraocular lens power calculation for eyeballs with axial length shorter than 22.0 mm. 2. The correlation between axial length and absolute error is a factor which should be considered when calculating intraocular lens power.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22024114
003      
CZ-PrNML
005      
20221207152922.0
007      
ta
008      
221017s2022 xr cd f 000 0|eng||
009      
AR
024    7_
$a 10.31348/2022/24 $2 doi
035    __
$a (PubMed)36220363
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Stopyra, Wiktor $u MW med Eye Centre, Cracow, Poland
245    14
$a The exactness of intraocular lens power calculation formulas for short eyes and correlation between method accuracy and eyeball axial length / $c W. Stopyra
520    9_
$a Purpose: To compare the accuracy of intraocular lens power calculation formulas and to examine the correlation of this exactness with the axial length for eyes shorter than 22.00 mm Methods: The data of hyperopic patients who underwent uneventful phacoemulsification between October 2015 and June 2019 were reviewed. The intraocular lens power for each patient was calculated using 6 formulas (Holladay1, SRK/T, Hoffer Q, Holladay 2, Haigis and Barrett Universal II) before cataract surgery. Postoperative refraction was measured, and refractive prediction error was calculated 3 months after phacoemulsification. The correlation between axial length and absolute error was evaluated. Results: Fifty-six patients (62 eyes) whose ocular axial length ranged between 20.58 mm and 21.97 mm were included in the study. The Hoffer Q formula achieved the lowest mean absolute error of 0.09 (±0.08 D). A significant correlation for the Hoffer Q (ρ = -0.329, p = 0.009) and the SRK/T (ρ = 0.321, p = 0.011) formula was observed. Conclusions: 1. The Hoffer Q formula obtained the lowest absolute error and was recommended for intraocular lens power calculation for eyeballs with axial length shorter than 22.0 mm. 2. The correlation between axial length and absolute error is a factor which should be considered when calculating intraocular lens power.
650    17
$a implantace nitrooční čočky $7 D019654 $2 czmesh
650    _7
$a hypermetropie $7 D006956 $2 czmesh
650    _7
$a fakoemulzifikace $7 D018918 $2 czmesh
650    _7
$a axiální délka oka $7 D058452 $2 czmesh
650    17
$a biometrie $x metody $7 D001699 $2 czmesh
650    _7
$a refrakce oka $x fyziologie $7 D012029 $2 czmesh
650    _7
$a lidé $7 D006801 $2 czmesh
650    17
$a refrakční vady $7 D012030 $2 czmesh
653    00
$a Hoffer Q formula
773    0_
$w MED00010980 $t Česká a slovenská oftalmologie $x 1211-9059 $g Roč. 78, č. 5 (2022), s. 236-240
856    41
$u https://www.prolekare.cz/casopisy/ceska-slovenska-oftalmologie/2022-5-2/the-exactness-of-intraocular-lens-power-calculation-formulas-for-short-eyes-and-correlation-between-method-accuracy-and-eyeball-axial-length-131896 $y plný text volně dostupný
910    __
$a ABA008 $b A 202 $c 639 $y p $z 0
990    __
$a 20221017 $b ABA008
991    __
$a 20221207152917 $b ABA008
999    __
$a ok $b bmc $g 1852122 $s 1175404
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 78 $c 5 $d 236-240 $i 1211-9059 $m Česká a slovenská oftalmologie $x MED00010980 $y 131896
LZP    __
$c NLK108 $d 20221207 $b NLK111 $a Meditorial-20221017

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...