Validation of a single tube 3-colour immature red blood cell screening assay for the detection and enumeration of small, medium and large paroxysmal nocturnal haemoglobinuria clones by flow cytometry

I. Marinov, SJ. Richards, A. Pešek, AJ. Illingworth, DR. Sutherland

. 2022 ; 44 (5) : 868-874. [pub] 20220525

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22024280

INTRODUCTION: The reliable diagnosis of paroxysmal nocturnal haemoglobinuria (PNH) by flow cytometry is based on mandatory analysis of the erythroid, neutrophilic and monocytic lineages. In this study, we have evaluated the performance characteristics of a recently published immature red blood cell (iRBC) assay as a potential screening test for PNH by flow cytometry. METHODS: Intra- and inter-assay imprecision were determined in five replicates of small, medium and large PNH iRBC clones. Analytical and functional sensitivity was assessed by performing spiking tests for five replicates. Thirty healthy donors and 441 PNH patients were tested for evaluation of clinical specificity, sensitivity, positive and negative predictive values. RESULTS: Coefficients of variation (CV) for intra-/inter-assay imprecision analyses were 1.31/1.50, 3.19/2.61 and 3.99/1.58 for the big, medium and small clone sizes, respectively. Absolute values (100%) were found for both clinical specificity and sensitivity as well as for both positive and negative predictive values. The CV from 5 replicate results for 10 clustered events was 15.7%. The coefficient of determination (r2 ), Pearson's correlation coefficient (r) and Bland-Altman mean bias were 0.9436/0.9234/1.7 for PNH iRBC compared to PNH neutrophils and 0.9553/0.9387/2.1 for PNH iRBCs compared to PNH monocytes. CONCLUSION: Our results confirm very good performance characteristics, high analytical and functional sensitivity, absolute clinical specificity and sensitivity as well as favourable correlation between PNH iRBCs and both PNH neutrophils and monocytes, suggesting that this cost-effective 3-colour iRBC assay can be used as a reliable screening test for evaluation of small, medium and large PNH clones by flow cytometry.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22024280
003      
CZ-PrNML
005      
20221031100238.0
007      
ta
008      
221017s2022 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1111/ijlh.13877 $2 doi
035    __
$a (PubMed)35614534
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Marinov, Iuri $u Clinical Department, Institute of Haematology and Blood Transfusion, Prague, Czech Republic $1 https://orcid.org/https://orcid.org/0000000300253131
245    10
$a Validation of a single tube 3-colour immature red blood cell screening assay for the detection and enumeration of small, medium and large paroxysmal nocturnal haemoglobinuria clones by flow cytometry / $c I. Marinov, SJ. Richards, A. Pešek, AJ. Illingworth, DR. Sutherland
520    9_
$a INTRODUCTION: The reliable diagnosis of paroxysmal nocturnal haemoglobinuria (PNH) by flow cytometry is based on mandatory analysis of the erythroid, neutrophilic and monocytic lineages. In this study, we have evaluated the performance characteristics of a recently published immature red blood cell (iRBC) assay as a potential screening test for PNH by flow cytometry. METHODS: Intra- and inter-assay imprecision were determined in five replicates of small, medium and large PNH iRBC clones. Analytical and functional sensitivity was assessed by performing spiking tests for five replicates. Thirty healthy donors and 441 PNH patients were tested for evaluation of clinical specificity, sensitivity, positive and negative predictive values. RESULTS: Coefficients of variation (CV) for intra-/inter-assay imprecision analyses were 1.31/1.50, 3.19/2.61 and 3.99/1.58 for the big, medium and small clone sizes, respectively. Absolute values (100%) were found for both clinical specificity and sensitivity as well as for both positive and negative predictive values. The CV from 5 replicate results for 10 clustered events was 15.7%. The coefficient of determination (r2 ), Pearson's correlation coefficient (r) and Bland-Altman mean bias were 0.9436/0.9234/1.7 for PNH iRBC compared to PNH neutrophils and 0.9553/0.9387/2.1 for PNH iRBCs compared to PNH monocytes. CONCLUSION: Our results confirm very good performance characteristics, high analytical and functional sensitivity, absolute clinical specificity and sensitivity as well as favourable correlation between PNH iRBCs and both PNH neutrophils and monocytes, suggesting that this cost-effective 3-colour iRBC assay can be used as a reliable screening test for evaluation of small, medium and large PNH clones by flow cytometry.
650    _2
$a buněčné klony $7 D002999
650    _2
$a barva $7 D003116
650    _2
$a erytrocyty $7 D004912
650    _2
$a průtoková cytometrie $x metody $7 D005434
650    12
$a paroxysmální hemoglobinurie $x diagnóza $7 D006457
650    _2
$a lidé $7 D006801
655    _2
$a časopisecké články $7 D016428
700    1_
$a Richards, Stephen J $u Division of Haematology and Immunology, Leeds Institute of Medical Research at St James's, University of Leeds, Leeds, UK
700    1_
$a Pešek, Adam $u Clinical Department, Institute of Haematology and Blood Transfusion, Prague, Czech Republic
700    1_
$a Illingworth, Andrea J $u Dahl-Chase Diagnostic Services, Bangor, Maine, USA $1 https://orcid.org/https://orcid.org/0000000302373591
700    1_
$a Sutherland, D Robert $u Department of Laboratory Medicine, Toronto General Hospital, Toronto, Ontario, Canada
773    0_
$w MED00153487 $t International journal of laboratory hematology $x 1751-553X $g Roč. 44, č. 5 (2022), s. 868-874
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35614534 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20221017 $b ABA008
991    __
$a 20221031100236 $b ABA008
999    __
$a ok $b bmc $g 1854162 $s 1175570
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 44 $c 5 $d 868-874 $e 20220525 $i 1751-553X $m International journal of laboratory hematology $n Int J Lab Hematol $x MED00153487
LZP    __
$a Pubmed-20221017

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...