-
Je něco špatně v tomto záznamu ?
Porcine spleen as a model organ for blunt injury impact tests: An experimental and histological study
P. Kochová, A. Malečková, R. Pálek, V. Liška, T. Bońkowski, M. Horák, M. Grajciarová, Z. Tonar
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články
Grantová podpora
CZ.02.1.01/0.0/0.0/17_048/0007280
European Regional Development Fund
ProgresQ39
Univerzita Karlova v Praze
CooperatioMED/DIAG
Univerzita Karlova v Praze
SVV260536
Univerzita Karlova v Praze
GAUK1098120
Univerzita Karlova v Praze
UNCE/MED/006
Univerzita Karlova v Praze
SGS-2022-008
Západočeská Univerzita v Plzni
PubMed
35751561
DOI
10.1111/ahe.12831
Knihovny.cz E-zdroje
- MeSH
- lidé MeSH
- nemoci prasat * MeSH
- prasata MeSH
- slezina MeSH
- tupá poranění * veterinární MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
The spleen is a large and highly vascularized secondary lymphatic organ. Spleen injuries are among the most frequent trauma-related injuries in the abdominal region. The aims of the study were to assess the volume fractions of the main splenic tissue components (red pulp, white pulp, trabeculae and reticular fibres) and to determine the severity of splenic injury due to the experimental impact test. Porcine spleens (n = 17) were compressed by 6.22 kg wooden plate using a drop tower technique from three impact heights (50, 100 and 150 mm corresponding to velocities 0.79, 1.24 and 1.58 m/s). The pressure was measured via catheters placed in the splenic vein. The impact velocity was measured using lasers. The severity of induced injuries was analysed on the macroscopic level. The volume fractions of splenic components were assessed microscopically using stereology. The volume fraction of the red pulp was 76.4%, white pulp 21.3% and trabeculae 2.7% respectively. All impact tests, even with the low impact velocities, led to injuries that occurred mostly in the dorsal extremity of the spleen, and were accompanied by bleeding, capsule rupture and parenchyma crushing. Higher impact height (impact velocity and impact energy) caused more severe injury. Porcine spleen had the same volume fraction of tissue components as human spleen, therefore we concluded that the porcine spleen was a suitable organ model for mechanical experiments. Based on our observations, regions around hilum and the diaphragmatic surface of the dorsal extremity, that contained fissures and notches, were the most prone to injury and required considerable attention during splenic examination after injury. The primary mechanical data are now available for the researchers focused on the splenic trauma modelling.
Department of Mechanics Faculty of Applied Sciences University of West Bohemia Pilsen Czech Republic
New Technologies Research Centre University of West Bohemia Pilsen Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22024506
- 003
- CZ-PrNML
- 005
- 20221031100352.0
- 007
- ta
- 008
- 221017s2022 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/ahe.12831 $2 doi
- 035 __
- $a (PubMed)35751561
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Kochová, Petra $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic
- 245 10
- $a Porcine spleen as a model organ for blunt injury impact tests: An experimental and histological study / $c P. Kochová, A. Malečková, R. Pálek, V. Liška, T. Bońkowski, M. Horák, M. Grajciarová, Z. Tonar
- 520 9_
- $a The spleen is a large and highly vascularized secondary lymphatic organ. Spleen injuries are among the most frequent trauma-related injuries in the abdominal region. The aims of the study were to assess the volume fractions of the main splenic tissue components (red pulp, white pulp, trabeculae and reticular fibres) and to determine the severity of splenic injury due to the experimental impact test. Porcine spleens (n = 17) were compressed by 6.22 kg wooden plate using a drop tower technique from three impact heights (50, 100 and 150 mm corresponding to velocities 0.79, 1.24 and 1.58 m/s). The pressure was measured via catheters placed in the splenic vein. The impact velocity was measured using lasers. The severity of induced injuries was analysed on the macroscopic level. The volume fractions of splenic components were assessed microscopically using stereology. The volume fraction of the red pulp was 76.4%, white pulp 21.3% and trabeculae 2.7% respectively. All impact tests, even with the low impact velocities, led to injuries that occurred mostly in the dorsal extremity of the spleen, and were accompanied by bleeding, capsule rupture and parenchyma crushing. Higher impact height (impact velocity and impact energy) caused more severe injury. Porcine spleen had the same volume fraction of tissue components as human spleen, therefore we concluded that the porcine spleen was a suitable organ model for mechanical experiments. Based on our observations, regions around hilum and the diaphragmatic surface of the dorsal extremity, that contained fissures and notches, were the most prone to injury and required considerable attention during splenic examination after injury. The primary mechanical data are now available for the researchers focused on the splenic trauma modelling.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a slezina $7 D013154
- 650 _2
- $a prasata $7 D013552
- 650 12
- $a nemoci prasat $7 D013553
- 650 12
- $a tupá poranění $x veterinární $7 D014949
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Malečková, Anna $u Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic $1 https://orcid.org/https://orcid.org/0000000326746268
- 700 1_
- $a Pálek, Richard $u Department of Surgery and Biomedical Center, Faculty of Medicine and University Hospital in Pilsen, Charles University, Pilsen, Czech Republic
- 700 1_
- $a Liška, Václav $u Department of Surgery and Biomedical Center, Faculty of Medicine and University Hospital in Pilsen, Charles University, Pilsen, Czech Republic
- 700 1_
- $a Bońkowski, Tomasz $u New Technologies - Research Centre, University of West Bohemia, Pilsen, Czech Republic
- 700 1_
- $a Horák, Miroslav $u Department of Mechanics, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic
- 700 1_
- $a Grajciarová, Martina $u Department of Histology and Embryology and Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
- 700 1_
- $a Tonar, Zbyněk $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic
- 773 0_
- $w MED00006253 $t Anatomia, histologia, embryologia $x 1439-0264 $g Roč. 51, č. 5 (2022), s. 576-586
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35751561 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20221017 $b ABA008
- 991 __
- $a 20221031100350 $b ABA008
- 999 __
- $a ok $b bmc $g 1854300 $s 1175796
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 51 $c 5 $d 576-586 $e 20220625 $i 1439-0264 $m Anatomia, Histologia, Embryologia $n Anat Histol Embryol $x MED00006253
- GRA __
- $a CZ.02.1.01/0.0/0.0/17_048/0007280 $p European Regional Development Fund
- GRA __
- $a ProgresQ39 $p Univerzita Karlova v Praze
- GRA __
- $a CooperatioMED/DIAG $p Univerzita Karlova v Praze
- GRA __
- $a SVV260536 $p Univerzita Karlova v Praze
- GRA __
- $a GAUK1098120 $p Univerzita Karlova v Praze
- GRA __
- $a UNCE/MED/006 $p Univerzita Karlova v Praze
- GRA __
- $a SGS-2022-008 $p Západočeská Univerzita v Plzni
- LZP __
- $a Pubmed-20221017