Retrospective OSL Dosimetry With Common Pharmaceuticals and Food Supplements

D. Ekendahl, D. Reimitz

. 2022 ; 10 (-) : 908016. [pub] 20220616

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22025417

Several common pharmaceuticals such as ibuprofen, paracetamol, aspirin, oral contraceptives, drugs for the prevention of motion sickness and food supplements such as table vitamins and minerals have been studied for the purposes of retrospective dosimetry using optically stimulated luminescence (OSL). The essence is that the tablets with these drug substances contain additive crystalline materials which, after irradiation and stimulation, may exhibit luminescence. For most of the pharmaceuticals and food supplements, a radiation-induced dose-dependent OSL signal was detected. Subsequently, basic dosimetric characteristics of the materials were studied, specifically sensitivity changes during repeated OSL readings, dose response, zero-dose, minimum detectable dose (MDD) and fading. The most radiation sensitive materials were food supplements with Mg providing zero-dose and MDD values at the level of several mGy. For Mg supplements, considerable sensitivity changes in OSL signal were observed. Despite this, they could be corrected using a Single-Aliquot Regenerative-dose (SAR) protocol. The OSL signals of the other materials were relatively weak but they were well reproducible and exhibited linear dose response. The MDD values were variable among the materials and ranged from 0.1 to several Gy. However, for some of the pharmaceuticals, a very high and variable zero-dose of more than 3 Gy was observed that would rule out the possibility of dose reconstruction for triage purposes. The OSL signal exhibited a significant fading rate for most of the materials. The measurements for dose reconstruction should be performed as soon as possible after irradiation, i.e. within a maximum of a few days.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22025417
003      
CZ-PrNML
005      
20221031100533.0
007      
ta
008      
221017s2022 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3389/fpubh.2022.908016 $2 doi
035    __
$a (PubMed)35784234
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Ekendahl, Daniela $u Department of Dosimetry, National Radiation Protection Institute, Prague, Czechia
245    10
$a Retrospective OSL Dosimetry With Common Pharmaceuticals and Food Supplements / $c D. Ekendahl, D. Reimitz
520    9_
$a Several common pharmaceuticals such as ibuprofen, paracetamol, aspirin, oral contraceptives, drugs for the prevention of motion sickness and food supplements such as table vitamins and minerals have been studied for the purposes of retrospective dosimetry using optically stimulated luminescence (OSL). The essence is that the tablets with these drug substances contain additive crystalline materials which, after irradiation and stimulation, may exhibit luminescence. For most of the pharmaceuticals and food supplements, a radiation-induced dose-dependent OSL signal was detected. Subsequently, basic dosimetric characteristics of the materials were studied, specifically sensitivity changes during repeated OSL readings, dose response, zero-dose, minimum detectable dose (MDD) and fading. The most radiation sensitive materials were food supplements with Mg providing zero-dose and MDD values at the level of several mGy. For Mg supplements, considerable sensitivity changes in OSL signal were observed. Despite this, they could be corrected using a Single-Aliquot Regenerative-dose (SAR) protocol. The OSL signals of the other materials were relatively weak but they were well reproducible and exhibited linear dose response. The MDD values were variable among the materials and ranged from 0.1 to several Gy. However, for some of the pharmaceuticals, a very high and variable zero-dose of more than 3 Gy was observed that would rule out the possibility of dose reconstruction for triage purposes. The OSL signal exhibited a significant fading rate for most of the materials. The measurements for dose reconstruction should be performed as soon as possible after irradiation, i.e. within a maximum of a few days.
650    _2
$a potravní doplňky $7 D019587
650    12
$a dozimetrie opticky stimulovanou luminiscencí $x metody $7 D062791
650    _2
$a léčivé přípravky $7 D004364
650    _2
$a dávka záření $7 D011829
650    _2
$a retrospektivní studie $7 D012189
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Reimitz, Dan $u Department of Dosimetry, National Radiation Protection Institute, Prague, Czechia
773    0_
$w MED00186211 $t Frontiers in public health $x 2296-2565 $g Roč. 10, č. - (2022), s. 908016
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35784234 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20221017 $b ABA008
991    __
$a 20221031100531 $b ABA008
999    __
$a ok $b bmc $g 1854903 $s 1176707
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 10 $c - $d 908016 $e 20220616 $i 2296-2565 $m Frontiers in public health $n Front Public Health $x MED00186211
LZP    __
$a Pubmed-20221017

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...