Je něco špatně v tomto záznamu ?
Mechanical Analyses of Quadriceps Tendon Graft with Five Different Fixation Techniques on the Femoral Side: an Experimental Study on Sheep Knees [Mechanická analýza štěpu šlachy kvadricepsu fixovaného pěti různými technikami na femorální straně: experimentální studie na ovčích kolenech]
M. Çeti N, MS. Söylemez, BY. Öztürk, I. Mutlu, Ö. Karakuş
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
- MeSH
- biomechanika MeSH
- Equidae MeSH
- kostní šrouby * MeSH
- ovce MeSH
- šlachy transplantace MeSH
- titan * MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE OF THE STUDY We aimed to evaluate the biomechanical properties of quadriceps tendon graft with a bone plug ending (QTBP) and a quadriceps graft with a tendinous ending(QTT) fixed on the femoral side with different fixation devices. MATERIAL AND METHODS Twenty-five paired 2-year-old calf QTs and 25 paired 2-year-old sheep femurs were used for this study. 90x8 mm central part of the quadriceps tendons with or without a bone plug was harvested. 8×25 mm tunnel was placed in lateral condyles. The QTT was fixed with four different fixation devices, including the adjustable suspensory system (QTT-ASS, group 1), biodegradable interference screws (QTT-BIS, group 2), titanium interference screws (QTT-TIS, group 3), and an adjustable suspensory system + biodegradable interference screws (QTT-(ASS+BIS), group 4); QTBP was fixed with titanium interference screws (QTBP-TIS, group 5). All groups were tested in a servohydraulic materials testing machine. Stiffness(N/mm), slippage of the tendon(mm), and the ultimate tensile load-bearing ability(N) of the groups were tested. The Kruskal-Wallis H test was used with the Monte Carlo simulation technique to compare the nonparametric variables of stiffness, slippage, and ultimate tensile load. Dunn's test was used for the post hoc analyses. RESULTS Group 3 had the stiffest fixation (median 45.09 N/mm). The amount of slippage was highest in group 1(median 6.41mm). Group 1 was the most resistant group against a tensile load during the load-to-failure test(464 N). Fixing the QTT with the ASS and BIS in group 4 increased both stiffness and ultimate tensile load strength. There was no significant difference between the QTBP and QTT fixed with titanium screws. Fixing QTT with titanium screws was significantly superior to fixation with BIS(p < 0.05). CONCLUSIONS This study demonstrates that QTBP fixation with TIS have no advantage over QTT fixation with TIS on the femoral side. Although the QTT group fixed with ASS was the most resistant group against tensile forces during load-to-failure test, amount of slippage was highest for this group as well. Thus, if an ASS is to be used, a strong tension force must be applied prior to tibial side fixation to prevent further slippage of the graft in the tunnel. Key words: anterior cruciate ligament, quadriceps tendon graft, femoral side, fixation, biomechanical properties.
Balikesir State Hospital Department of Orthopaedics and Traumatology Balikesir Turkey
Kocaeli University Faculty of Technology Department of Biomedical Engineering Istanbul Turkey
Umraniye Training and Research Hospital Department of Orthopaedics and Traumatology Istanbul Turkey
Mechanická analýza štěpu šlachy kvadricepsu fixovaného pěti různými technikami na femorální straně: experimentální studie na ovčích kolenech
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22026942
- 003
- CZ-PrNML
- 005
- 20230426100936.0
- 007
- ta
- 008
- 221108s2022 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.55095/achot2022/047 $2 doi
- 035 __
- $a (PubMed)36055670
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Çetin, M. $u Fatih Sultan Mehmet Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey
- 245 10
- $a Mechanical Analyses of Quadriceps Tendon Graft with Five Different Fixation Techniques on the Femoral Side: an Experimental Study on Sheep Knees / $c M. Çeti N, MS. Söylemez, BY. Öztürk, I. Mutlu, Ö. Karakuş
- 246 31
- $a Mechanická analýza štěpu šlachy kvadricepsu fixovaného pěti různými technikami na femorální straně: experimentální studie na ovčích kolenech
- 520 9_
- $a PURPOSE OF THE STUDY We aimed to evaluate the biomechanical properties of quadriceps tendon graft with a bone plug ending (QTBP) and a quadriceps graft with a tendinous ending(QTT) fixed on the femoral side with different fixation devices. MATERIAL AND METHODS Twenty-five paired 2-year-old calf QTs and 25 paired 2-year-old sheep femurs were used for this study. 90x8 mm central part of the quadriceps tendons with or without a bone plug was harvested. 8×25 mm tunnel was placed in lateral condyles. The QTT was fixed with four different fixation devices, including the adjustable suspensory system (QTT-ASS, group 1), biodegradable interference screws (QTT-BIS, group 2), titanium interference screws (QTT-TIS, group 3), and an adjustable suspensory system + biodegradable interference screws (QTT-(ASS+BIS), group 4); QTBP was fixed with titanium interference screws (QTBP-TIS, group 5). All groups were tested in a servohydraulic materials testing machine. Stiffness(N/mm), slippage of the tendon(mm), and the ultimate tensile load-bearing ability(N) of the groups were tested. The Kruskal-Wallis H test was used with the Monte Carlo simulation technique to compare the nonparametric variables of stiffness, slippage, and ultimate tensile load. Dunn's test was used for the post hoc analyses. RESULTS Group 3 had the stiffest fixation (median 45.09 N/mm). The amount of slippage was highest in group 1(median 6.41mm). Group 1 was the most resistant group against a tensile load during the load-to-failure test(464 N). Fixing the QTT with the ASS and BIS in group 4 increased both stiffness and ultimate tensile load strength. There was no significant difference between the QTBP and QTT fixed with titanium screws. Fixing QTT with titanium screws was significantly superior to fixation with BIS(p < 0.05). CONCLUSIONS This study demonstrates that QTBP fixation with TIS have no advantage over QTT fixation with TIS on the femoral side. Although the QTT group fixed with ASS was the most resistant group against tensile forces during load-to-failure test, amount of slippage was highest for this group as well. Thus, if an ASS is to be used, a strong tension force must be applied prior to tibial side fixation to prevent further slippage of the graft in the tunnel. Key words: anterior cruciate ligament, quadriceps tendon graft, femoral side, fixation, biomechanical properties.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a biomechanika $7 D001696
- 650 12
- $a kostní šrouby $7 D001863
- 650 _2
- $a Equidae $7 D018397
- 650 _2
- $a ovce $7 D012756
- 650 _2
- $a šlachy $x transplantace $7 D013710
- 650 12
- $a titan $7 D014025
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Söylemez, M. S. $u Umraniye Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey
- 700 1_
- $a Öztürk, B. Y. $u Umraniye Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey
- 700 1_
- $a Mutlu, I. $u Kocaeli University, Faculty of Technology, Department of Biomedical Engineering, Istanbul, Turkey
- 700 1_
- $a Karakuş, Ö. $u Balikesir State Hospital, Department of Orthopaedics and Traumatology, Balikesir, Turkey
- 773 0_
- $w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca $x 0001-5415 $g Roč. 89, č. 4 (2022), s. 293-299
- 856 41
- $u https://achot.cz/pdfs/ach/2022/04/08.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 8 $c 507 $y p $z 0
- 990 __
- $a 20221108 $b ABA008
- 991 __
- $a 20230426100932 $b ABA008
- 999 __
- $a ok $b bmc $g 1892757 $s 1178249
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 89 $c 4 $d 293-299 $e - $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
- LZP __
- $b NLK198 $a Pubmed-20221108