Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Mechanical Analyses of Quadriceps Tendon Graft with Five Different Fixation Techniques on the Femoral Side: an Experimental Study on Sheep Knees [Mechanická analýza štěpu šlachy kvadricepsu fixovaného pěti různými technikami na femorální straně: experimentální studie na ovčích kolenech]

M. Çeti N, MS. Söylemez, BY. Öztürk, I. Mutlu, Ö. Karakuş

. 2022 ; 89 (4) : 293-299. [pub] -

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22026942

PURPOSE OF THE STUDY We aimed to evaluate the biomechanical properties of quadriceps tendon graft with a bone plug ending (QTBP) and a quadriceps graft with a tendinous ending(QTT) fixed on the femoral side with different fixation devices. MATERIAL AND METHODS Twenty-five paired 2-year-old calf QTs and 25 paired 2-year-old sheep femurs were used for this study. 90x8 mm central part of the quadriceps tendons with or without a bone plug was harvested. 8×25 mm tunnel was placed in lateral condyles. The QTT was fixed with four different fixation devices, including the adjustable suspensory system (QTT-ASS, group 1), biodegradable interference screws (QTT-BIS, group 2), titanium interference screws (QTT-TIS, group 3), and an adjustable suspensory system + biodegradable interference screws (QTT-(ASS+BIS), group 4); QTBP was fixed with titanium interference screws (QTBP-TIS, group 5). All groups were tested in a servohydraulic materials testing machine. Stiffness(N/mm), slippage of the tendon(mm), and the ultimate tensile load-bearing ability(N) of the groups were tested. The Kruskal-Wallis H test was used with the Monte Carlo simulation technique to compare the nonparametric variables of stiffness, slippage, and ultimate tensile load. Dunn's test was used for the post hoc analyses. RESULTS Group 3 had the stiffest fixation (median 45.09 N/mm). The amount of slippage was highest in group 1(median 6.41mm). Group 1 was the most resistant group against a tensile load during the load-to-failure test(464 N). Fixing the QTT with the ASS and BIS in group 4 increased both stiffness and ultimate tensile load strength. There was no significant difference between the QTBP and QTT fixed with titanium screws. Fixing QTT with titanium screws was significantly superior to fixation with BIS(p < 0.05). CONCLUSIONS This study demonstrates that QTBP fixation with TIS have no advantage over QTT fixation with TIS on the femoral side. Although the QTT group fixed with ASS was the most resistant group against tensile forces during load-to-failure test, amount of slippage was highest for this group as well. Thus, if an ASS is to be used, a strong tension force must be applied prior to tibial side fixation to prevent further slippage of the graft in the tunnel. Key words: anterior cruciate ligament, quadriceps tendon graft, femoral side, fixation, biomechanical properties.

Mechanická analýza štěpu šlachy kvadricepsu fixovaného pěti různými technikami na femorální straně: experimentální studie na ovčích kolenech

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22026942
003      
CZ-PrNML
005      
20230426100936.0
007      
ta
008      
221108s2022 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.55095/achot2022/047 $2 doi
035    __
$a (PubMed)36055670
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Çetin, M. $u Fatih Sultan Mehmet Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey
245    10
$a Mechanical Analyses of Quadriceps Tendon Graft with Five Different Fixation Techniques on the Femoral Side: an Experimental Study on Sheep Knees / $c M. Çeti N, MS. Söylemez, BY. Öztürk, I. Mutlu, Ö. Karakuş
246    31
$a Mechanická analýza štěpu šlachy kvadricepsu fixovaného pěti různými technikami na femorální straně: experimentální studie na ovčích kolenech
520    9_
$a PURPOSE OF THE STUDY We aimed to evaluate the biomechanical properties of quadriceps tendon graft with a bone plug ending (QTBP) and a quadriceps graft with a tendinous ending(QTT) fixed on the femoral side with different fixation devices. MATERIAL AND METHODS Twenty-five paired 2-year-old calf QTs and 25 paired 2-year-old sheep femurs were used for this study. 90x8 mm central part of the quadriceps tendons with or without a bone plug was harvested. 8×25 mm tunnel was placed in lateral condyles. The QTT was fixed with four different fixation devices, including the adjustable suspensory system (QTT-ASS, group 1), biodegradable interference screws (QTT-BIS, group 2), titanium interference screws (QTT-TIS, group 3), and an adjustable suspensory system + biodegradable interference screws (QTT-(ASS+BIS), group 4); QTBP was fixed with titanium interference screws (QTBP-TIS, group 5). All groups were tested in a servohydraulic materials testing machine. Stiffness(N/mm), slippage of the tendon(mm), and the ultimate tensile load-bearing ability(N) of the groups were tested. The Kruskal-Wallis H test was used with the Monte Carlo simulation technique to compare the nonparametric variables of stiffness, slippage, and ultimate tensile load. Dunn's test was used for the post hoc analyses. RESULTS Group 3 had the stiffest fixation (median 45.09 N/mm). The amount of slippage was highest in group 1(median 6.41mm). Group 1 was the most resistant group against a tensile load during the load-to-failure test(464 N). Fixing the QTT with the ASS and BIS in group 4 increased both stiffness and ultimate tensile load strength. There was no significant difference between the QTBP and QTT fixed with titanium screws. Fixing QTT with titanium screws was significantly superior to fixation with BIS(p < 0.05). CONCLUSIONS This study demonstrates that QTBP fixation with TIS have no advantage over QTT fixation with TIS on the femoral side. Although the QTT group fixed with ASS was the most resistant group against tensile forces during load-to-failure test, amount of slippage was highest for this group as well. Thus, if an ASS is to be used, a strong tension force must be applied prior to tibial side fixation to prevent further slippage of the graft in the tunnel. Key words: anterior cruciate ligament, quadriceps tendon graft, femoral side, fixation, biomechanical properties.
650    _2
$a zvířata $7 D000818
650    _2
$a biomechanika $7 D001696
650    12
$a kostní šrouby $7 D001863
650    _2
$a Equidae $7 D018397
650    _2
$a ovce $7 D012756
650    _2
$a šlachy $x transplantace $7 D013710
650    12
$a titan $7 D014025
655    _2
$a časopisecké články $7 D016428
700    1_
$a Söylemez, M. S. $u Umraniye Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey
700    1_
$a Öztürk, B. Y. $u Umraniye Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey
700    1_
$a Mutlu, I. $u Kocaeli University, Faculty of Technology, Department of Biomedical Engineering, Istanbul, Turkey
700    1_
$a Karakuş, Ö. $u Balikesir State Hospital, Department of Orthopaedics and Traumatology, Balikesir, Turkey
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca $x 0001-5415 $g Roč. 89, č. 4 (2022), s. 293-299
856    41
$u https://achot.cz/pdfs/ach/2022/04/08.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 8 $c 507 $y p $z 0
990    __
$a 20221108 $b ABA008
991    __
$a 20230426100932 $b ABA008
999    __
$a ok $b bmc $g 1892757 $s 1178249
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 89 $c 4 $d 293-299 $e - $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$b NLK198 $a Pubmed-20221108

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...