Modeling and Measurement of an Ultrasound Power Delivery System for Charging Implantable Devices Using an AlN-Based pMUT as Receiver
A. Proto, L. Rufer, S. Basrour, M. Penhaker
Status neindexováno Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
PubMed Central od 2016
Europe PubMed Central od 2016
ProQuest Central od 2010-03-01
Open Access Digital Library od 2010-01-01
ROAD: Directory of Open Access Scholarly Resources od 2010
Odkazy
PubMed
36557427
DOI
10.3390/mi13122127
Knihovny.cz E-zdroje
- Publikační typ
- časopisecké články MeSH
Ultrasound power delivery can be considered a convenient technique for charging implantable medical devices. In this work, an intra-body system has been modeled to characterize the phenomenon of ultrasound power transmission. The proposed system comprises a Langevin transducer as transmitter and an AlN-based square piezoelectric micro-machined ultrasonic transducer as receiver. The medium layers, in which elastic waves propagate, were made by polydimethylsiloxane to mimic human tissue and stainless steel to replace the case of the implantable device. To characterize the behavior of the transducers, measurements of impedance and phase, velocity and displacement, and acoustic pressure field were carried out in the experimental activity. Then, voltage and power output were measured to analyze the performance of the ultrasound power delivery system. For a root mean square voltage input of approximately 35 V, the power density resulted in 21.6 μW cm-2. Such a result corresponds to the data obtained with simulation through a one-dimensional lumped parameter transmission line model. The methodology proposed to develop the ultrasound power delivery (UPD) system, as well as the use of non-toxic materials for the fabrication of the intra-body elements, are a valid design approach to raise awareness of using wireless power transfer techniques for charging implantable devices.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22031141
- 003
- CZ-PrNML
- 005
- 20230127131044.0
- 007
- ta
- 008
- 230119s2022 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/mi13122127 $2 doi
- 035 __
- $a (PubMed)36557427
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Proto, Antonino $u Department of Neuroscience and Rehabilitation, University of Ferrara, Via Luigi Borsari, 46, 44121 Ferrara, Italy $u Department of Cybernetics and Biomedical Engineering, VŠB-Technical University of Ostrava, 17.listopadu 2172/15, Poruba, 708 00 Ostrava, Czech Republic $1 https://orcid.org/0000000319648184
- 245 10
- $a Modeling and Measurement of an Ultrasound Power Delivery System for Charging Implantable Devices Using an AlN-Based pMUT as Receiver / $c A. Proto, L. Rufer, S. Basrour, M. Penhaker
- 520 9_
- $a Ultrasound power delivery can be considered a convenient technique for charging implantable medical devices. In this work, an intra-body system has been modeled to characterize the phenomenon of ultrasound power transmission. The proposed system comprises a Langevin transducer as transmitter and an AlN-based square piezoelectric micro-machined ultrasonic transducer as receiver. The medium layers, in which elastic waves propagate, were made by polydimethylsiloxane to mimic human tissue and stainless steel to replace the case of the implantable device. To characterize the behavior of the transducers, measurements of impedance and phase, velocity and displacement, and acoustic pressure field were carried out in the experimental activity. Then, voltage and power output were measured to analyze the performance of the ultrasound power delivery system. For a root mean square voltage input of approximately 35 V, the power density resulted in 21.6 μW cm-2. Such a result corresponds to the data obtained with simulation through a one-dimensional lumped parameter transmission line model. The methodology proposed to develop the ultrasound power delivery (UPD) system, as well as the use of non-toxic materials for the fabrication of the intra-body elements, are a valid design approach to raise awareness of using wireless power transfer techniques for charging implantable devices.
- 590 __
- $a NEINDEXOVÁNO
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Rufer, Libor $u Université Grenoble Alpes, CNRS, Grenoble INP, TIMA, 38000 Grenoble, France $1 https://orcid.org/0000000212262994
- 700 1_
- $a Basrour, Skandar $u Université Grenoble Alpes, CNRS, Grenoble INP, TIMA, 38000 Grenoble, France $1 https://orcid.org/0000000311647996
- 700 1_
- $a Penhaker, Marek $u Department of Cybernetics and Biomedical Engineering, VŠB-Technical University of Ostrava, 17.listopadu 2172/15, Poruba, 708 00 Ostrava, Czech Republic $1 https://orcid.org/0000000195274642
- 773 0_
- $w MED00197318 $t Micromachines $x 2072-666X $g Roč. 13, č. 12 (2022)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/36557427 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20230119 $b ABA008
- 991 __
- $a 20230127131036 $b ABA008
- 999 __
- $a ok $b bmc $g 1889383 $s 1182474
- BAS __
- $a 3
- BAS __
- $a PreBMC-PubMed-not-MEDLINE
- BMC __
- $a 2022 $b 13 $c 12 $e 20221201 $i 2072-666X $m Micromachines $n Micromachines (Basel) $x MED00197318
- LZP __
- $a Pubmed-20230119