• Je něco špatně v tomto záznamu ?

Statistical Study on Human Temperature Measurement by Infrared Thermography

M. Švantner, V. Lang, J. Skála, T. Kohlschütter, M. Honner, L. Muzika, E. Kosová

. 2022 ; 22 (21) : . [pub] 20221101

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22032773

Increased temperature in humans is the symptom of many infectious diseases and it is thus an important diagnostic tool. Infrared temperature measurement methods have been developed and applied over long periods due to their advantage of non-contact and fast measurements. This study deals with a statistical evaluation of the possibilities and limitations of infrared/thermographic human temperature measurement. A short review of the use of infrared temperature measurement in medical applications is provided. Experiments and statistics-based evaluation to confirm the expected accuracy and limits of thermography-based human temperature measurement are introduced. The results presented in this study show that the standard deviation of the thermographic measurement of the eyes maximum temperature was 0.4-0.9 °C and the mean values differences from the armpit measurement were up to 0.5 °C, based on the used IR camera, even though near ideal measurement conditions and permanent blackbody correction were used. It was also shown that a certain number of outliers must be assumed in such measurements. Extended analyses including simulations of true negative/false positive, sensitivity/specificity and receiver operating characteristics (ROC) curves are presented. The statistical evaluation as well as the extended analyses show that maximum eyes temperature is more relevant than a forehead temperature examination.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22032773
003      
CZ-PrNML
005      
20230131150808.0
007      
ta
008      
230120s2022 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/s22218395 $2 doi
035    __
$a (PubMed)36366093
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Švantner, Michal $u New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic $1 https://orcid.org/0000000193917069
245    10
$a Statistical Study on Human Temperature Measurement by Infrared Thermography / $c M. Švantner, V. Lang, J. Skála, T. Kohlschütter, M. Honner, L. Muzika, E. Kosová
520    9_
$a Increased temperature in humans is the symptom of many infectious diseases and it is thus an important diagnostic tool. Infrared temperature measurement methods have been developed and applied over long periods due to their advantage of non-contact and fast measurements. This study deals with a statistical evaluation of the possibilities and limitations of infrared/thermographic human temperature measurement. A short review of the use of infrared temperature measurement in medical applications is provided. Experiments and statistics-based evaluation to confirm the expected accuracy and limits of thermography-based human temperature measurement are introduced. The results presented in this study show that the standard deviation of the thermographic measurement of the eyes maximum temperature was 0.4-0.9 °C and the mean values differences from the armpit measurement were up to 0.5 °C, based on the used IR camera, even though near ideal measurement conditions and permanent blackbody correction were used. It was also shown that a certain number of outliers must be assumed in such measurements. Extended analyses including simulations of true negative/false positive, sensitivity/specificity and receiver operating characteristics (ROC) curves are presented. The statistical evaluation as well as the extended analyses show that maximum eyes temperature is more relevant than a forehead temperature examination.
650    _2
$a lidé $7 D006801
650    12
$a termografie $x metody $7 D013817
650    _2
$a teplota $7 D013696
650    12
$a infračervené záření $7 D007259
650    _2
$a tělesná teplota $7 D001831
650    _2
$a horečka $x diagnóza $7 D005334
655    _2
$a časopisecké články $7 D016428
700    1_
$a Lang, Vladislav $u New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic
700    1_
$a Skála, Jiří $u New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic
700    1_
$a Kohlschütter, Tomáš $u New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic
700    1_
$a Honner, Milan $u New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic $1 https://orcid.org/0000000310640936
700    1_
$a Muzika, Lukáš $u New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic $1 https://orcid.org/0000000348987169
700    1_
$a Kosová, Eliška $u New Technologies-Research Centre, University of West Bohemia, 301 00 Pilsen, Czech Republic
773    0_
$w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 22, č. 21 (2022)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36366093 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230120 $b ABA008
991    __
$a 20230131150804 $b ABA008
999    __
$a ok $b bmc $g 1891484 $s 1184108
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2022 $b 22 $c 21 $e 20221101 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
LZP    __
$a Pubmed-20230120

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace