Feasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis
L. Matera, P. Sajgalik, V. Fabian, Y. Mikhailov, D. Zemanek, BD. Johnson
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
36236381
DOI
10.3390/s22197285
Knihovny.cz E-zdroje
- MeSH
- analýza pulzové vlny * MeSH
- arteria brachialis * fyziologie MeSH
- dospělí MeSH
- krevní tlak fyziologie MeSH
- lidé MeSH
- měření krevního tlaku metody MeSH
- mladý dospělý MeSH
- prsty ruky MeSH
- srdeční frekvence MeSH
- studie proveditelnosti MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Czech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver). Twelve healthy adult subjects [2 females, age = (27.2 ± 5.1) years] were in the upright siting position, breathe through the mouthpiece (simultaneously acquisition by brachial blood pressure monitor and Finapres) and at a defined time were asked to generate positive mouth pressure for 20 s (Valsalva). For the purpose of signal analysis, we proposed parameter a "Occlusion Cuff Index" (OCCI). The assumption about similarities between measured signals (suprasystolic brachial pulse waves amplitudes and Finapres's MAP) were proved by averaged Pearson's correlation coefficient (r- = 0.60, p < 0.001). The averaged Pearson's correlation coefficient for the comparative analysis of OCCI between methods was r- = 0.88, p < 0.001. The average percent change of OCCI during maneuver: 8% increase, 19% decrease and percent change of max/min ratio is 35%. The investigation of brachial pulse waves measured by novel brachial blood pressure monitor shows positive correlation with Finapres and the parameter OCCI shows promise as an index, which could describe changes during beat-to-beat cardiac cycles.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22033273
- 003
- CZ-PrNML
- 005
- 20230131150804.0
- 007
- ta
- 008
- 230120s2022 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s22197285 $2 doi
- 035 __
- $a (PubMed)36236381
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Matera, Lukas $u Department of Physics, Faculty of Electrical Engineering, Czech Technical University in Prague, 16627 Prague, Czech Republic $1 https://orcid.org/0000000271209544
- 245 10
- $a Feasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis / $c L. Matera, P. Sajgalik, V. Fabian, Y. Mikhailov, D. Zemanek, BD. Johnson
- 520 9_
- $a Czech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver). Twelve healthy adult subjects [2 females, age = (27.2 ± 5.1) years] were in the upright siting position, breathe through the mouthpiece (simultaneously acquisition by brachial blood pressure monitor and Finapres) and at a defined time were asked to generate positive mouth pressure for 20 s (Valsalva). For the purpose of signal analysis, we proposed parameter a "Occlusion Cuff Index" (OCCI). The assumption about similarities between measured signals (suprasystolic brachial pulse waves amplitudes and Finapres's MAP) were proved by averaged Pearson's correlation coefficient (r- = 0.60, p < 0.001). The averaged Pearson's correlation coefficient for the comparative analysis of OCCI between methods was r- = 0.88, p < 0.001. The average percent change of OCCI during maneuver: 8% increase, 19% decrease and percent change of max/min ratio is 35%. The investigation of brachial pulse waves measured by novel brachial blood pressure monitor shows positive correlation with Finapres and the parameter OCCI shows promise as an index, which could describe changes during beat-to-beat cardiac cycles.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a krevní tlak $x fyziologie $7 D001794
- 650 _2
- $a měření krevního tlaku $x metody $7 D001795
- 650 12
- $a arteria brachialis $x fyziologie $7 D001916
- 650 _2
- $a studie proveditelnosti $7 D005240
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a prsty ruky $7 D005385
- 650 _2
- $a srdeční frekvence $7 D006339
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a analýza pulzové vlny $7 D063177
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Sajgalik, Pavol $u Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN 55905, USA
- 700 1_
- $a Fabian, Vratislav $u Department of Physics, Faculty of Electrical Engineering, Czech Technical University in Prague, 16627 Prague, Czech Republic $1 https://orcid.org/0000000263900116
- 700 1_
- $a Mikhailov, Yegor $u Department of Physics, Faculty of Electrical Engineering, Czech Technical University in Prague, 16627 Prague, Czech Republic
- 700 1_
- $a Zemanek, David $u 2nd Department of Internal Medicine-Cardiology and Angiology of General University Hospital and 1st Medical Faculty of Charles University, 12808 Prague, Czech Republic
- 700 1_
- $a Johnson, Bruce D $u Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN 55905, USA
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 22, č. 19 (2022)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/36236381 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20230120 $b ABA008
- 991 __
- $a 20230131150800 $b ABA008
- 999 __
- $a ok $b bmc $g 1891824 $s 1184608
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2022 $b 22 $c 19 $e 20220926 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- LZP __
- $a Pubmed-20230120