Comparison of end-expiratory lung volume measurement by electrical impedance tomography and nitrogen washout method in pigs
Martin Müller, Karel Roubík
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem, hodnotící studie
- Klíčová slova
- elektrická impedanční tomografie, nitrogen washout method,
- MeSH
- hospodářská zvířata MeSH
- měření objemu plic * metody MeSH
- prasata MeSH
- tomografie metody MeSH
- ventilace umělá s výdechovým přetlakem metody MeSH
- Publikační typ
- hodnotící studie MeSH
- práce podpořená grantem MeSH
End-expiratory lung volume (EELV) can be determined using several methods that allow clinically accurate measurements, but it is difficult to apply these methods to the patient's bedside. Electrical impedance tomography (EIT) is offered as another method for measuring EELV. The aim of the study is to compare changes in EELV measured by nitrogen washout method with changes of EELV calculated from the change in end-expiratory lung impedance (EELI) measured by EIT and to determine whether changes in EELV calculated from changes in chest impedance can be used as one of the parameters for EIT data analysis and description. The prospective interventional animal study was performed on ten pigs. The animals received total intravenous anesthesia with muscle relaxation. Mechanical lung ventilation was conducted in the volume-controlled mode. 16-electrode EIT system was used for data acquisition. End-expiratory lung volume was measured by a modified nitrogen wash-in/wash-out technique developed by Olegard et al. The study protocol consisted of the baseline phase, two incremental PEEP steps, two decremental PEEP steps and from normal saline i. v. administration. For each animal, a reference frame (baseline frame) was selected from the initial baseline phase and was used for the reconstruction of EIT images and impedance waveforms. For each breath cycle, tidal variation image was calculated as a difference between the end-inspiratory and the previous end-expiratory EIT image. An equivalent end-expiratory volume change (ΔEELVequiv) was calculated from EELI. The values of ΔEELVequiv were compared with reference EELV data measured by a modified nitrogen wash-in/wash-out technique (ΔEELVmeas). The measured and the estimated changes in EELV were statistically compared and correlation between ΔEELVequiv and ΔEELVmeas was calculated. Statistically significant difference between ΔEELVequiv and ΔEELVmeas was observed only in administration of normal saline bolus. Pearson’s correlation coefficients were 0.29 for increase in PEEP, 0.45 for decrease in PEEP and -0.1 during administration of normal saline bolus. The study showed that during changes in PEEP in the porcine model, there was no linear relationship between ΔEELVequiv and ΔEELVmeas. Although there was no linear relationship between ΔEELVequiv and ΔEELVmeas with changes in PEEP, no statistically significant difference was demonstrated between these two methods, which justifies the use of ΔEELVequiv as a parameter suitable for description and evaluation of EIT data.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23006605
- 003
- CZ-PrNML
- 005
- 20231010091337.0
- 007
- ta
- 008
- 230517s2020 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14311/CTJ.2020.4.05 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Müller, Martin $7 xx0228490 $u Department of Anesthesiology and Intensive Care of the 1st Faculty of Medicine and Thomayer University Hospital, Prague, Czech Republic
- 245 10
- $a Comparison of end-expiratory lung volume measurement by electrical impedance tomography and nitrogen washout method in pigs / $c Martin Müller, Karel Roubík
- 504 __
- $a Literatura
- 520 9_
- $a End-expiratory lung volume (EELV) can be determined using several methods that allow clinically accurate measurements, but it is difficult to apply these methods to the patient's bedside. Electrical impedance tomography (EIT) is offered as another method for measuring EELV. The aim of the study is to compare changes in EELV measured by nitrogen washout method with changes of EELV calculated from the change in end-expiratory lung impedance (EELI) measured by EIT and to determine whether changes in EELV calculated from changes in chest impedance can be used as one of the parameters for EIT data analysis and description. The prospective interventional animal study was performed on ten pigs. The animals received total intravenous anesthesia with muscle relaxation. Mechanical lung ventilation was conducted in the volume-controlled mode. 16-electrode EIT system was used for data acquisition. End-expiratory lung volume was measured by a modified nitrogen wash-in/wash-out technique developed by Olegard et al. The study protocol consisted of the baseline phase, two incremental PEEP steps, two decremental PEEP steps and from normal saline i. v. administration. For each animal, a reference frame (baseline frame) was selected from the initial baseline phase and was used for the reconstruction of EIT images and impedance waveforms. For each breath cycle, tidal variation image was calculated as a difference between the end-inspiratory and the previous end-expiratory EIT image. An equivalent end-expiratory volume change (ΔEELVequiv) was calculated from EELI. The values of ΔEELVequiv were compared with reference EELV data measured by a modified nitrogen wash-in/wash-out technique (ΔEELVmeas). The measured and the estimated changes in EELV were statistically compared and correlation between ΔEELVequiv and ΔEELVmeas was calculated. Statistically significant difference between ΔEELVequiv and ΔEELVmeas was observed only in administration of normal saline bolus. Pearson’s correlation coefficients were 0.29 for increase in PEEP, 0.45 for decrease in PEEP and -0.1 during administration of normal saline bolus. The study showed that during changes in PEEP in the porcine model, there was no linear relationship between ΔEELVequiv and ΔEELVmeas. Although there was no linear relationship between ΔEELVequiv and ΔEELVmeas with changes in PEEP, no statistically significant difference was demonstrated between these two methods, which justifies the use of ΔEELVequiv as a parameter suitable for description and evaluation of EIT data.
- 650 17
- $a měření objemu plic $x metody $7 D008176 $2 czmesh
- 650 _7
- $a ventilace umělá s výdechovým přetlakem $x metody $7 D011175 $2 czmesh
- 650 _7
- $a tomografie $x metody $7 D014054 $2 czmesh
- 650 _7
- $a prasata $7 D013552 $2 czmesh
- 650 _7
- $a hospodářská zvířata $7 D000829 $2 czmesh
- 653 00
- $a elektrická impedanční tomografie
- 653 00
- $a nitrogen washout method
- 655 _7
- $a práce podpořená grantem $7 D013485 $2 czmesh
- 655 _7
- $a hodnotící studie $7 D023362 $2 czmesh
- 700 1_
- $a Roubík, Karel, $d 1971- $7 ntka173892 $u Czech Technical University in Prague, Faculty of Biomedical Engineering
- 773 0_
- $t Lékař a technika $x 0301-5491 $g Roč. 50, č. 4 (2020), s. 146-151 $w MED00011033
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y p $z 0
- 990 __
- $a 20230517141648 $b ABA008
- 991 __
- $a 20231010091330 $b ABA008
- 999 __
- $a ok $b bmc $g 1933664 $s 1192827
- BAS __
- $a 3
- BMC __
- $a 2020 $b 50 $c 4 $d 146-151 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
- LZP __
- $c NLK197 $d 20231006 $a NLK 2023-16/kv