Small nanofibrous disks for preconcentration of environmental contaminants followed by direct in-vial elution and chromatographic determination

S. Zatrochová, I. Lhotská, J. Erben, J. Chvojka, F. Švec, P. Chocholouš, D. Šatínský

. 2023 ; 263 (-) : 124688. [pub] 20230525

Status neindexováno Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc23009448

A novel method for the extraction of river water contaminants as model analytes of ranging polarities, including bisphenols A, C, S, Z, fenoxycarb, kadethrin, and deltamethrin, using small compact fibrous disks has been developed and validated. Polymer nanofibers and microfibers prepared from poly(3-hydroxybutyrate), polypropylene, polyurethane, polyacrylonitrile, poly(lactic acid), and polycaprolactone doped with graphene were evaluated in terms of extraction efficiency, selectivity, and stability in organic solutions. Our novel extraction procedure comprised preconcentration of analytes from 150 mL river water to 1 mL of eluent using a compact nanofibrous disk freely vortexed in the sample. Small nanofibrous disks with a diameter of 10 mm were cut from a compact and mechanically stable 1-2 mm thick micro/nanofibrous sheet. After 60 min extraction in a magnetically stirred sample located in a beaker, the disk was removed from the liquid and washed with water. Then, the disk was inserted into a 1.5 mL HPLC vial and extracted with 1.0 ml methanol upon short intensive shaking. Our approach avoided the undesired problems related to the manual handling typical of "classical" SPE procedure since the extraction was carried out directly in the HPLC vial. No sample evaporation, reconstitution, or pipetting was required. The nanofibrous disk is affordable, needs no support or holder, and its use avoids creation of plastic waste originating from disposable materials. Recovery of compounds from the disks was 47.2-141.4% depending on the type of polymer used and the relative standard deviations calculated from 5 extractions ranged from 6.1 to 11.8% for poly(3-hydroxybutyrate), 6.3-14.8% for polyurethane, and 1.7-16.2% for polycaprolactone doped with graphene. A small enrichment factor was obtained for polar bisphenol S using all sorbents. A higher preconcentration reaching up to 40-fold was achieved for lipophilic compounds such as deltamethrin when using poly(3-hydroxybutyrate) and graphene-doped polycaprolactone.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23009448
003      
CZ-PrNML
005      
20230721095603.0
007      
ta
008      
230707s2023 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2023.124688 $2 doi
035    __
$a (PubMed)37247455
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Zatrochová, Slavomíra $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic
245    10
$a Small nanofibrous disks for preconcentration of environmental contaminants followed by direct in-vial elution and chromatographic determination / $c S. Zatrochová, I. Lhotská, J. Erben, J. Chvojka, F. Švec, P. Chocholouš, D. Šatínský
520    9_
$a A novel method for the extraction of river water contaminants as model analytes of ranging polarities, including bisphenols A, C, S, Z, fenoxycarb, kadethrin, and deltamethrin, using small compact fibrous disks has been developed and validated. Polymer nanofibers and microfibers prepared from poly(3-hydroxybutyrate), polypropylene, polyurethane, polyacrylonitrile, poly(lactic acid), and polycaprolactone doped with graphene were evaluated in terms of extraction efficiency, selectivity, and stability in organic solutions. Our novel extraction procedure comprised preconcentration of analytes from 150 mL river water to 1 mL of eluent using a compact nanofibrous disk freely vortexed in the sample. Small nanofibrous disks with a diameter of 10 mm were cut from a compact and mechanically stable 1-2 mm thick micro/nanofibrous sheet. After 60 min extraction in a magnetically stirred sample located in a beaker, the disk was removed from the liquid and washed with water. Then, the disk was inserted into a 1.5 mL HPLC vial and extracted with 1.0 ml methanol upon short intensive shaking. Our approach avoided the undesired problems related to the manual handling typical of "classical" SPE procedure since the extraction was carried out directly in the HPLC vial. No sample evaporation, reconstitution, or pipetting was required. The nanofibrous disk is affordable, needs no support or holder, and its use avoids creation of plastic waste originating from disposable materials. Recovery of compounds from the disks was 47.2-141.4% depending on the type of polymer used and the relative standard deviations calculated from 5 extractions ranged from 6.1 to 11.8% for poly(3-hydroxybutyrate), 6.3-14.8% for polyurethane, and 1.7-16.2% for polycaprolactone doped with graphene. A small enrichment factor was obtained for polar bisphenol S using all sorbents. A higher preconcentration reaching up to 40-fold was achieved for lipophilic compounds such as deltamethrin when using poly(3-hydroxybutyrate) and graphene-doped polycaprolactone.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Lhotská, Ivona $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic
700    1_
$a Erben, Jakub $u The Technical University of Liberec, Faculty of Textile Engineering, Department of Nonwovens and Nanofibrous Materials, Studentská 1402/2, 46001, Liberec 1, Czech Republic
700    1_
$a Chvojka, Jiří $u The Technical University of Liberec, Faculty of Textile Engineering, Department of Nonwovens and Nanofibrous Materials, Studentská 1402/2, 46001, Liberec 1, Czech Republic
700    1_
$a Švec, František $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic
700    1_
$a Chocholouš, Petr $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic
700    1_
$a Šatínský, Dalibor $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic. Electronic address: satinsky@faf.cuni.cz
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 263, č. - (2023), s. 124688
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37247455 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230707 $b ABA008
991    __
$a 20230721095556 $b ABA008
999    __
$a ok $b bmc $g 1958379 $s 1195712
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2023 $b 263 $c - $d 124688 $e 20230525 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20230707

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...