• Je něco špatně v tomto záznamu ?

Newly Designed 3D-Printed Sonication Test Cell Optimized for In Vitro Sonication Experiments

M. Snehota, M. Kolarikova, J. Vachutka, B. Hosikova, K. Balazova, L. Dolezal, H. Kolarova

. 2023 ; 49 (9) : 2042-2053. [pub] 20230615

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc23016409

OBJECTIVE: Precise control over the ultrasound field parameters experienced by biological samples during sonication experiments in vitro may be quite challenging. The main goal of this work was to outline an approach to construction of sonication test cells that would minimize the interaction between the test cells and ultrasound. METHODS: Optimal dimensions of the test cell were determined through measurements conducted in a water sonication tank using 3D-printed test objects. The offset of local acoustic intensity variability inside the sonication test cell was set to value of ±50% of the reference value (i.e., local acoustic intensity measured at last axial maximum in the free-field condition). The cytotoxicity of several materials used for 3D printing was determined using the MTT (3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide) assay. RESULTS: The sonication test cells were 3D printed from polylactic acid material, which was not toxic to the cells. Silicone membrane HT-6240, which was used to construct the bottom of the test cell, was found to reduce ultrasound energy minimally. Final ultrasound profiles inside the sonication test cells indicated the desired variability of local acoustic intensity. The cell viability in our sonication test cell was comparable to that of commercial culture plates with bottoms constructed with silicone membrane. CONCLUSION: An approach to construction of sonication test cells minimizing the interaction of the test cell and ultrasound has been outlined.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23016409
003      
CZ-PrNML
005      
20231026105905.0
007      
ta
008      
231013s2023 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ultrasmedbio.2023.05.009 $2 doi
035    __
$a (PubMed)37330389
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Snehota, Martin $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
245    10
$a Newly Designed 3D-Printed Sonication Test Cell Optimized for In Vitro Sonication Experiments / $c M. Snehota, M. Kolarikova, J. Vachutka, B. Hosikova, K. Balazova, L. Dolezal, H. Kolarova
520    9_
$a OBJECTIVE: Precise control over the ultrasound field parameters experienced by biological samples during sonication experiments in vitro may be quite challenging. The main goal of this work was to outline an approach to construction of sonication test cells that would minimize the interaction between the test cells and ultrasound. METHODS: Optimal dimensions of the test cell were determined through measurements conducted in a water sonication tank using 3D-printed test objects. The offset of local acoustic intensity variability inside the sonication test cell was set to value of ±50% of the reference value (i.e., local acoustic intensity measured at last axial maximum in the free-field condition). The cytotoxicity of several materials used for 3D printing was determined using the MTT (3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide) assay. RESULTS: The sonication test cells were 3D printed from polylactic acid material, which was not toxic to the cells. Silicone membrane HT-6240, which was used to construct the bottom of the test cell, was found to reduce ultrasound energy minimally. Final ultrasound profiles inside the sonication test cells indicated the desired variability of local acoustic intensity. The cell viability in our sonication test cell was comparable to that of commercial culture plates with bottoms constructed with silicone membrane. CONCLUSION: An approach to construction of sonication test cells minimizing the interaction of the test cell and ultrasound has been outlined.
650    12
$a vibrace ultrazvukové $x metody $7 D013010
650    12
$a ablace intenzivním ultrazvukovým paprskem $x metody $7 D057086
650    _2
$a ultrasonografie $7 D014463
650    _2
$a 3D tisk $7 D066330
650    _2
$a silikony $7 D012828
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Kolarikova, Marketa $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
700    1_
$a Vachutka, Jaromir $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
700    1_
$a Hosikova, Barbora $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic. Electronic address: barbora.hosikova@upol.cz
700    1_
$a Balazova, Klara $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
700    1_
$a Dolezal, Ladislav $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
700    1_
$a Kolarova, Hana $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
773    0_
$w MED00004601 $t Ultrasound in medicine & biology $x 1879-291X $g Roč. 49, č. 9 (2023), s. 2042-2053
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37330389 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20231013 $b ABA008
991    __
$a 20231026105859 $b ABA008
999    __
$a ok $b bmc $g 2000119 $s 1202771
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 49 $c 9 $d 2042-2053 $e 20230615 $i 1879-291X $m Ultrasound in medicine & biology $n Ultrasound Med Biol $x MED00004601
LZP    __
$a Pubmed-20231013

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...