-
Je něco špatně v tomto záznamu ?
Mechanical complications and infection control comparison of custom-made and prefabricated articular hip spacers in the treatment of periprosthetic infection
J. Emmer, T. Tomáš, V. Apostolopoulos, P. Brančík, J. Rapi, L. Nachtnebl
Jazyk angličtina Země Turecko
Typ dokumentu časopisecké články
PubMed
37750259
DOI
10.52312/jdrs.2023.1155
Knihovny.cz E-zdroje
- MeSH
- dislokace kloubu * MeSH
- kontrola infekce MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhrada kyčelního kloubu * škodlivé účinky MeSH
- odstranění implantátu škodlivé účinky MeSH
- retrospektivní studie MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: The purpose of our study was to compare the complication rate and the outcomes of custom-made spacers (C-spacers) and prefabricated articular spacers (P-spacers) in the treatment of periprosthetic infection. PATIENTS AND METHODS: In this retrospective study, 78 patients (44 females, 34 males; mean age: 68.5±9.48 years; range, 47 to 82 years) with articular spacers implanted in our institution were analyzed between January 2009 and December 2019. We recorded implant results as per mechanical complications, infection control, the interval from surgery to definitive hip replacement, and the rate of achieving recovery of joint function after stage two arthroplasty. RESULTS: There were 29 revised spacers; 18 of them were C-spacers and 11 were P-spacers (p=0.0383). A total of 16 dislocations were recorded, of which six were dislocations of C-spacers, and 10 were dislocations of P-spacers (p=0.0082). Additionally, we registered four spacer breakages, all of which occurred in C-spacers (p=0.295). C-spacers failed early, at an mean interval of 2.2 weeks after implantation, and P-spacers failed later, with an mean of 9.3 weeks after implantation (p=0.0187). A total of nine reinfection complications of spacers were registered; only one infection of P-spacers, and eight infections related to C-spacers (p=0.2583). Definitive revision total hip arthroplasty (rTHA) after spacer explantation and successful treatment of the infection occurred in 63 cases out of 78 patients. Definitive rTHA occurred after the use of C-spacers in 41 (78%) patients and after the use of C-spacers in 22 (84%) patients (p=0.7816). C-spacers had a mean interval from spacer implantation to definitive rTHA of 6.56±6.03 months, and P-spacers had a mean interval of 4±1.93 months (p=0.0164). CONCLUSION: Custom-made spacers were shown to have lower mechanical complication rates than prefabricated ones but more infection complications. Prefabricated spacers had more dislocations and fewer breakages. Custom-made spacer mechanical failures occurred earlier compared to prefabricated ones.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23016534
- 003
- CZ-PrNML
- 005
- 20240716101535.0
- 007
- ta
- 008
- 231013s2023 tu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.52312/jdrs.2023.1155 $2 doi
- 035 __
- $a (PubMed)37750259
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a tu
- 100 1_
- $a Emmer, Jan $7 xx0301350
- 245 10
- $a Mechanical complications and infection control comparison of custom-made and prefabricated articular hip spacers in the treatment of periprosthetic infection / $c J. Emmer, T. Tomáš, V. Apostolopoulos, P. Brančík, J. Rapi, L. Nachtnebl
- 520 9_
- $a OBJECTIVES: The purpose of our study was to compare the complication rate and the outcomes of custom-made spacers (C-spacers) and prefabricated articular spacers (P-spacers) in the treatment of periprosthetic infection. PATIENTS AND METHODS: In this retrospective study, 78 patients (44 females, 34 males; mean age: 68.5±9.48 years; range, 47 to 82 years) with articular spacers implanted in our institution were analyzed between January 2009 and December 2019. We recorded implant results as per mechanical complications, infection control, the interval from surgery to definitive hip replacement, and the rate of achieving recovery of joint function after stage two arthroplasty. RESULTS: There were 29 revised spacers; 18 of them were C-spacers and 11 were P-spacers (p=0.0383). A total of 16 dislocations were recorded, of which six were dislocations of C-spacers, and 10 were dislocations of P-spacers (p=0.0082). Additionally, we registered four spacer breakages, all of which occurred in C-spacers (p=0.295). C-spacers failed early, at an mean interval of 2.2 weeks after implantation, and P-spacers failed later, with an mean of 9.3 weeks after implantation (p=0.0187). A total of nine reinfection complications of spacers were registered; only one infection of P-spacers, and eight infections related to C-spacers (p=0.2583). Definitive revision total hip arthroplasty (rTHA) after spacer explantation and successful treatment of the infection occurred in 63 cases out of 78 patients. Definitive rTHA occurred after the use of C-spacers in 41 (78%) patients and after the use of C-spacers in 22 (84%) patients (p=0.7816). C-spacers had a mean interval from spacer implantation to definitive rTHA of 6.56±6.03 months, and P-spacers had a mean interval of 4±1.93 months (p=0.0164). CONCLUSION: Custom-made spacers were shown to have lower mechanical complication rates than prefabricated ones but more infection complications. Prefabricated spacers had more dislocations and fewer breakages. Custom-made spacer mechanical failures occurred earlier compared to prefabricated ones.
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 12
- $a náhrada kyčelního kloubu $x škodlivé účinky $7 D019644
- 650 _2
- $a odstranění implantátu $x škodlivé účinky $7 D020878
- 650 _2
- $a kontrola infekce $7 D017053
- 650 12
- $a dislokace kloubu $7 D004204
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Tomáš, Tomáš
- 700 1_
- $a Apostolopoulos, Vasileios
- 700 1_
- $a Brančík, Pavel
- 700 1_
- $a Rapi, Jakub
- 700 1_
- $a Nachtnebl, Luboš $u Masaryk University, Orthopaed Department 1, FN Sv Anny Brne, Pekarska 53, Brno 60200, Czechia. lubos.nachtnebl@fnusa.cz
- 773 0_
- $w MED00214018 $t Joint diseases and related surgery $x 2687-4792 $g Roč. 34, č. 3 (2023), s. 557-564
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37750259 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20231013 $b ABA008
- 991 __
- $a 20240716101532 $b ABA008
- 999 __
- $a ok $b bmc $g 2000195 $s 1202896
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 34 $c 3 $d 557-564 $e 20230821 $i 2687-4792 $m Joint diseases and related surgery $n Jt Dis Relat Surg $x MED00214018
- LZP __
- $a Pubmed-20231013