Something wrong with this record ?
Proposals of guidance values for surface contamination by antineoplastic drugs based on long term monitoring in Czech and Slovak hospitals and pharmacies
L. Bláhová, L. Bláha, L. Doležalová, J. Kuta, T. Hojdarová
Language English Country Switzerland
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Directory of Open Access Journals
from 2013
Free Medical Journals
from 2013
PubMed Central
from 2013
Europe PubMed Central
from 2013
Open Access Digital Library
from 2013-01-01
Open Access Digital Library
from 2013-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2013
- MeSH
- Chromatography, Liquid MeSH
- Cyclophosphamide analysis MeSH
- Fluorouracil analysis MeSH
- Pharmacies * MeSH
- Humans MeSH
- Hospitals MeSH
- Occupational Exposure * analysis MeSH
- Antineoplastic Agents * MeSH
- Tandem Mass Spectrometry MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Geographicals
- Czech Republic MeSH
- Slovakia MeSH
INTRODUCTION: The exposures to hazardous antineoplastic drugs (AD) represent serious risks for health care personnel but the exposure limits are not commonly established because of the no-threshold effects (genotoxic action, carcinogenicity) of many ADs. In this study, we discussed and derived practically applicable technical guidance values (TGV) suitable for management of AD risks. METHODS: The long-term monitoring of surface contamination by eight ADs was performed in pharmacies and hospitals in the Czech Republic and Slovak Republic in 2008-2021; in total 2,223 unique samples were collected repeatedly in 48 facilities. AD contamination was studied by LC-MS/MS for cyclophosphamide, ifosfamide, methotrexate, irinotecan, paclitaxel, 5-fluorouracil and gemcitabine and by ICP-MS for total Pt as a marker of platinum-based ADs. RESULTS: The study highlighted importance of exposure biomarkers like 5-fluorouracil and especially carcinogenic and persistent cyclophosphamide, which should be by default included in monitoring along with other ADs. Highly contaminated spots like interiors of laminar biological safety cabinets represent a specific issue, where monitoring of contamination does not bring much added value, and prevention of staff and separated cleaning procedures should be priority. Rooms and surfaces in health care facilities that should be virtually free of ADs (e.g., offices, kitchenettes, daily rooms) were contaminated with lower frequency and concentrations but any contamination in these areas should be carefully examined. DISCUSSION AND CONCLUSIONS: For all other working places, i.e., majority of areas in pharmacies and hospitals, where ADs are being prepared, packaged, stored, transported, or administered to patients, the study proposes a generic TGV of 100 pg/cm2. The analysis of long-term monitoring data of multiple ADs showed that the exceedance of one TGV can serve as an indicator and trigger for improvement of working practices contributing thus to minimizing of unintended exposures and creating a safe work environment.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24001239
- 003
- CZ-PrNML
- 005
- 20240213094449.0
- 007
- ta
- 008
- 240109e20230914sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3389/fpubh.2023.1235496 $2 doi
- 035 __
- $a (PubMed)37780438
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Bláhová, Lucie $u RECETOX, Faculty of Science, Masaryk University, Brno, Czechia
- 245 10
- $a Proposals of guidance values for surface contamination by antineoplastic drugs based on long term monitoring in Czech and Slovak hospitals and pharmacies / $c L. Bláhová, L. Bláha, L. Doležalová, J. Kuta, T. Hojdarová
- 520 9_
- $a INTRODUCTION: The exposures to hazardous antineoplastic drugs (AD) represent serious risks for health care personnel but the exposure limits are not commonly established because of the no-threshold effects (genotoxic action, carcinogenicity) of many ADs. In this study, we discussed and derived practically applicable technical guidance values (TGV) suitable for management of AD risks. METHODS: The long-term monitoring of surface contamination by eight ADs was performed in pharmacies and hospitals in the Czech Republic and Slovak Republic in 2008-2021; in total 2,223 unique samples were collected repeatedly in 48 facilities. AD contamination was studied by LC-MS/MS for cyclophosphamide, ifosfamide, methotrexate, irinotecan, paclitaxel, 5-fluorouracil and gemcitabine and by ICP-MS for total Pt as a marker of platinum-based ADs. RESULTS: The study highlighted importance of exposure biomarkers like 5-fluorouracil and especially carcinogenic and persistent cyclophosphamide, which should be by default included in monitoring along with other ADs. Highly contaminated spots like interiors of laminar biological safety cabinets represent a specific issue, where monitoring of contamination does not bring much added value, and prevention of staff and separated cleaning procedures should be priority. Rooms and surfaces in health care facilities that should be virtually free of ADs (e.g., offices, kitchenettes, daily rooms) were contaminated with lower frequency and concentrations but any contamination in these areas should be carefully examined. DISCUSSION AND CONCLUSIONS: For all other working places, i.e., majority of areas in pharmacies and hospitals, where ADs are being prepared, packaged, stored, transported, or administered to patients, the study proposes a generic TGV of 100 pg/cm2. The analysis of long-term monitoring data of multiple ADs showed that the exceedance of one TGV can serve as an indicator and trigger for improvement of working practices contributing thus to minimizing of unintended exposures and creating a safe work environment.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a lékárny $7 D010594
- 650 _2
- $a chromatografie kapalinová $7 D002853
- 650 12
- $a pracovní expozice $x analýza $7 D016273
- 650 _2
- $a tandemová hmotnostní spektrometrie $7 D053719
- 650 12
- $a protinádorové látky $7 D000970
- 650 _2
- $a cyklofosfamid $x analýza $7 D003520
- 650 _2
- $a fluoruracil $x analýza $7 D005472
- 650 _2
- $a nemocnice $7 D006761
- 651 _2
- $a Slovenská republika $7 D018154
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Bláha, Luěek $u RECETOX, Faculty of Science, Masaryk University, Brno, Czechia
- 700 1_
- $a Doležalová, Lenka $u Masaryk Memorial Cancer Institute, Brno, Czechia
- 700 1_
- $a Kuta, Jan $u RECETOX, Faculty of Science, Masaryk University, Brno, Czechia
- 700 1_
- $a Hojdarová, Tereza $u RECETOX, Faculty of Science, Masaryk University, Brno, Czechia
- 773 0_
- $w MED00186211 $t Frontiers in public health $x 2296-2565 $g Roč. 11 (20230914), s. 1235496
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37780438 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240109 $b ABA008
- 991 __
- $a 20240213094446 $b ABA008
- 999 __
- $a ok $b bmc $g 2049697 $s 1210933
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 11 $c - $d 1235496 $e 20230914 $i 2296-2565 $m Frontiers in public health $n Front Public Health $x MED00186211
- LZP __
- $a Pubmed-20240109