INTRODUCTION: The subject of this study was the creation of a new type of laboratory walking stress test for the Special Forces of the Army of the Czech Republic. This study developed a test model that has been validated in practice and that reflects the fact that the performance of endurance without and with a load varies considerably. Especially, if we focus on operators, as their activities are always performed with loads/full gear (equipment, weapons, equipment, etc.). MATERIALS AND METHODS: 24 men/operators from the Special Forces of the Army of the Czech Republic volunteered for this study. The maximal exercise test/spiroergometry was designed to include performance at a load of 55 kg/121 lb, a constant speed of 5.3 km/h, and an increase in incline angle of 1 degree after each elapsed minute. The test was performed on a treadmill under standard time, location, and temperature conditions. During the test, the following values were recorded: VO2 = oxygen consumption indicating the intensity of the exercise was monitored, VO2/kg = oxygen consumption converted to body weight, VO2/HR = pulse oxygen (the amount of oxygen converted in one heartbeat), HR = heart rate, VE = ventilation, volume of air exhaled in 1 min, breathe frequency (BF) = respiratory rate in 1 min. RESULTS: Out of the total number of 24 respondents, the study found these mean values of variables. The variable mapping the oxygen consumption, which indicates the intensity of VO2 loading, was 3.8, with the lowest value being 3.2 and the highest being 4.5. After converting oxygen consumption to bodyweight, VO2/kg was 46, the lowest value of 38.8, and the highest 53.0 were measured for this variable. Pulse oxygen, i.e., the amount of oxygen calculated per heart contraction VO2/HR, was 20.5, the lowest value 16.0, and the highest 26.0. The average HR heart rate was 183.5, with the lowest value being recorded at 164 and the highest value is 205. Ventilation, i.e., the amount of exhaled air per minute in VE, was measured at 144.9, the lowest value was 114.7, and the highest was 176.6. The BF in 1 min was 58.5, the lowest value 35, and the highest 70. The mean time load was 10:20 min, the shortest test length was 7:25 min, and the longest was 13:23 min. These values correspond to the degree of inclination of the ascent, i.e., the mean value was 10 degrees, the smallest achieved slope was 7 degrees, and the largest 13 degrees. CONCLUSION: The designed weighted walking test proved to be fully functional and effective in measurement. The further established protocol corresponds to the requirements of the current needs of the Special Forces of the Army of the Czech Republic. Last but not least, the walking stress test is applied for the external and internal selection and screening of operators. Data obtained from testing were used to develop deployment requirements for patrol/nuclear combat missions.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24007049
003      
CZ-PrNML
005      
20240423155708.0
007      
ta
008      
240412s2024 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/milmed/usad387 $2 doi
035    __
$a (PubMed)37776528
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Bugala, Martin $u Department of Physical Education and Social Sciences, Faculty of Sports Studies Masaryk University, Brno 625 00, Czech Republic $1 https://orcid.org/0000000344024971
245    10
$a Load Carrying Walking Test for the Special Operation Forces of the Army of the Czech Republic / $c M. Bugala, M. Bernaciková, I. Struhár
520    9_
$a INTRODUCTION: The subject of this study was the creation of a new type of laboratory walking stress test for the Special Forces of the Army of the Czech Republic. This study developed a test model that has been validated in practice and that reflects the fact that the performance of endurance without and with a load varies considerably. Especially, if we focus on operators, as their activities are always performed with loads/full gear (equipment, weapons, equipment, etc.). MATERIALS AND METHODS: 24 men/operators from the Special Forces of the Army of the Czech Republic volunteered for this study. The maximal exercise test/spiroergometry was designed to include performance at a load of 55 kg/121 lb, a constant speed of 5.3 km/h, and an increase in incline angle of 1 degree after each elapsed minute. The test was performed on a treadmill under standard time, location, and temperature conditions. During the test, the following values were recorded: VO2 = oxygen consumption indicating the intensity of the exercise was monitored, VO2/kg = oxygen consumption converted to body weight, VO2/HR = pulse oxygen (the amount of oxygen converted in one heartbeat), HR = heart rate, VE = ventilation, volume of air exhaled in 1 min, breathe frequency (BF) = respiratory rate in 1 min. RESULTS: Out of the total number of 24 respondents, the study found these mean values of variables. The variable mapping the oxygen consumption, which indicates the intensity of VO2 loading, was 3.8, with the lowest value being 3.2 and the highest being 4.5. After converting oxygen consumption to bodyweight, VO2/kg was 46, the lowest value of 38.8, and the highest 53.0 were measured for this variable. Pulse oxygen, i.e., the amount of oxygen calculated per heart contraction VO2/HR, was 20.5, the lowest value 16.0, and the highest 26.0. The average HR heart rate was 183.5, with the lowest value being recorded at 164 and the highest value is 205. Ventilation, i.e., the amount of exhaled air per minute in VE, was measured at 144.9, the lowest value was 114.7, and the highest was 176.6. The BF in 1 min was 58.5, the lowest value 35, and the highest 70. The mean time load was 10:20 min, the shortest test length was 7:25 min, and the longest was 13:23 min. These values correspond to the degree of inclination of the ascent, i.e., the mean value was 10 degrees, the smallest achieved slope was 7 degrees, and the largest 13 degrees. CONCLUSION: The designed weighted walking test proved to be fully functional and effective in measurement. The further established protocol corresponds to the requirements of the current needs of the Special Forces of the Army of the Czech Republic. Last but not least, the walking stress test is applied for the external and internal selection and screening of operators. Data obtained from testing were used to develop deployment requirements for patrol/nuclear combat missions.
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé $7 D006801
650    12
$a spotřeba kyslíku $x fyziologie $7 D010101
650    12
$a cvičení $x fyziologie $7 D015444
650    _2
$a zátěžový test $7 D005080
650    _2
$a srdeční frekvence $7 D006339
650    _2
$a kyslík $7 D010100
650    _2
$a chůze $7 D016138
651    _2
$a Česká republika $7 D018153
655    _2
$a časopisecké články $7 D016428
700    1_
$a Bernaciková, Martina $u Department of Physical Activities and Health Sciences, Faculty of Sports Studies Masaryk University, Brno 625 00, Czech Republic $1 https://orcid.org/0000000182158554
700    1_
$a Struhár, Ivan $u Department of Physical Activities and Health Sciences, Faculty of Sports Studies Masaryk University, Brno 625 00, Czech Republic $1 https://orcid.org/0000000227320026
773    0_
$w MED00003360 $t Military medicine $x 1930-613X $g Roč. 189, č. 3-4 (2024), s. e566-e572
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37776528 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240412 $b ABA008
991    __
$a 20240423155704 $b ABA008
999    __
$a ok $b bmc $g 2081198 $s 1216816
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 189 $c 3-4 $d e566-e572 $e 20240227 $i 1930-613X $m Military medicine $n Mil Med $x MED00003360
GRA    __
$a MUNI/51/09/2020 $p Masarykova Univerzita
LZP    __
$a Pubmed-20240412

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...