-
Je něco špatně v tomto záznamu ?
Prolonged use of closed-loop inspired oxygen support in preterm infants: a randomised controlled trial
TMR. Schouten, A. Abu-Hanna, AH. van Kaam, MEN. van den Heuvel, TE. Bachman, RW. van Leuteren, GJ. Hutten, W. Onland
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu randomizované kontrolované studie, časopisecké články
NLK
ProQuest Central
od 1997-01-01 do Před 6 měsíci
Health & Medicine (ProQuest)
od 1997-01-01 do Před 6 měsíci
- MeSH
- hypoxie prevence a kontrola MeSH
- klinické křížové studie MeSH
- kojenec MeSH
- kyslík * MeSH
- lidé MeSH
- novorozenec nedonošený * MeSH
- novorozenec MeSH
- porodní hmotnost MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
OBJECTIVE: This randomised study in preterm infants on non-invasive respiratory support investigated the effectiveness of automated oxygen control (A-FiO2) in keeping the oxygen saturation (SpO2) within a target range (TR) during a 28-day period compared with manual titration (M-FiO2). DESIGN: A single-centre randomised control trial. SETTING: A level III neonatal intensive care unit. PATIENTS: Preterm infants (<28 weeks' gestation) on non-invasive respiratory support. INTERVENTIONS: A-FiO2 versus M-FiO2 control. METHODS: Main outcomes were the proportion of time spent and median area of episodes in the TR, hyperoxaemia, hypoxaemia and the trend over 28 days using a linear random intercept model. RESULTS: 23 preterm infants (median gestation 25.7 weeks; birth weight 820 g) were randomised. Compared with M-FiO2, the time spent within TR was higher in the A-FiO2 group (68.7% vs 48.0%, p<0.001). Infants in the A-FiO2 group spent less time in hyperoxaemia (13.8% vs 37.7%, p<0.001), but no difference was found in hypoxaemia. The time-based analyses showed that the A-FiO2 efficacy may differ over time, especially for hypoxaemia. Compared with the M-FiO2 group, the A-FiO2 group had a larger intercept but with an inversed slope for the daily median area below the TR (intercept 70.1 vs 36.3; estimate/day -0.70 vs 0.69, p<0.001). CONCLUSION: A-FiO2 control was superior to manual control in keeping preterm infants on non-invasive respiratory support in a prespecified TR over a period of 28 days. This improvement may come at the expense of increased time below the TR in the first days after initiating A-FiO2 control. TRIAL REGISTRATION NUMBER: NTR6731.
Amsterdam Public Health Research Institute Amsterdam the Netherlands
Amsterdam Reproduction and Development Amsterdam the Netherlands
Czech Technical University Prague Praha Czech Republic
Department of Medical Informatics University of Amsterdam Amsterdam the Netherlands
Department of Neonatology Emma Children's Hospital Amsterdam UMC Amsterdam the Netherlands
Department of Pediatrics and Neonatology OLVG Amsterdam the Netherlands
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24007099
- 003
- CZ-PrNML
- 005
- 20240423155723.0
- 007
- ta
- 008
- 240412s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1136/archdischild-2023-325831 $2 doi
- 035 __
- $a (PubMed)37827816
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Schouten, Tim M R $u Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, Amsterdam, the Netherlands $u Department of Medical Informatics, University of Amsterdam, Amsterdam, the Netherlands
- 245 10
- $a Prolonged use of closed-loop inspired oxygen support in preterm infants: a randomised controlled trial / $c TMR. Schouten, A. Abu-Hanna, AH. van Kaam, MEN. van den Heuvel, TE. Bachman, RW. van Leuteren, GJ. Hutten, W. Onland
- 520 9_
- $a OBJECTIVE: This randomised study in preterm infants on non-invasive respiratory support investigated the effectiveness of automated oxygen control (A-FiO2) in keeping the oxygen saturation (SpO2) within a target range (TR) during a 28-day period compared with manual titration (M-FiO2). DESIGN: A single-centre randomised control trial. SETTING: A level III neonatal intensive care unit. PATIENTS: Preterm infants (<28 weeks' gestation) on non-invasive respiratory support. INTERVENTIONS: A-FiO2 versus M-FiO2 control. METHODS: Main outcomes were the proportion of time spent and median area of episodes in the TR, hyperoxaemia, hypoxaemia and the trend over 28 days using a linear random intercept model. RESULTS: 23 preterm infants (median gestation 25.7 weeks; birth weight 820 g) were randomised. Compared with M-FiO2, the time spent within TR was higher in the A-FiO2 group (68.7% vs 48.0%, p<0.001). Infants in the A-FiO2 group spent less time in hyperoxaemia (13.8% vs 37.7%, p<0.001), but no difference was found in hypoxaemia. The time-based analyses showed that the A-FiO2 efficacy may differ over time, especially for hypoxaemia. Compared with the M-FiO2 group, the A-FiO2 group had a larger intercept but with an inversed slope for the daily median area below the TR (intercept 70.1 vs 36.3; estimate/day -0.70 vs 0.69, p<0.001). CONCLUSION: A-FiO2 control was superior to manual control in keeping preterm infants on non-invasive respiratory support in a prespecified TR over a period of 28 days. This improvement may come at the expense of increased time below the TR in the first days after initiating A-FiO2 control. TRIAL REGISTRATION NUMBER: NTR6731.
- 650 _2
- $a kojenec $7 D007223
- 650 _2
- $a novorozenec $7 D007231
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a novorozenec nedonošený $7 D007234
- 650 12
- $a kyslík $7 D010100
- 650 _2
- $a klinické křížové studie $7 D018592
- 650 _2
- $a porodní hmotnost $7 D001724
- 650 _2
- $a hypoxie $x prevence a kontrola $7 D000860
- 655 _2
- $a randomizované kontrolované studie $7 D016449
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Abu-Hanna, Ameen $u Department of Medical Informatics, University of Amsterdam, Amsterdam, the Netherlands $u Amsterdam Public Health Research Institute, Amsterdam, the Netherlands
- 700 1_
- $a van Kaam, Anton H $u Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, Amsterdam, the Netherlands $u Amsterdam Reproduction & Development, Amsterdam, the Netherlands
- 700 1_
- $a van den Heuvel, Maria E N $u Department of Pediatrics and Neonatology, OLVG, Amsterdam, the Netherlands
- 700 1_
- $a Bachman, Thomas E $u Czech Technical University in Prague, Praha, Czech Republic $1 https://orcid.org/0000000239689402
- 700 1_
- $a van Leuteren, Ruud W $u Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, Amsterdam, the Netherlands $u Amsterdam Reproduction & Development, Amsterdam, the Netherlands $1 https://orcid.org/0000000184682544
- 700 1_
- $a Hutten, G Jeroen $u Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, Amsterdam, the Netherlands $u Amsterdam Reproduction & Development, Amsterdam, the Netherlands
- 700 1_
- $a Onland, Wes $u Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, Amsterdam, the Netherlands w.onland@amsterdamumc.nl $u Amsterdam Reproduction & Development, Amsterdam, the Netherlands $1 https://orcid.org/0000000296230606
- 773 0_
- $w MED00004943 $t Archives of disease in childhood. Fetal and neonatal edition $x 1468-2052 $g Roč. 109, č. 2 (2024), s. 221-226
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37827816 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240412 $b ABA008
- 991 __
- $a 20240423155719 $b ABA008
- 999 __
- $a ok $b bmc $g 2081222 $s 1216866
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 109 $c 2 $d 221-226 $e 20240219 $i 1468-2052 $m Archives of disease in childhood. Fetal and neonatal edition $n Arch Dis Child Fetal Neonatal Ed $x MED00004943
- LZP __
- $a Pubmed-20240412