-
Je něco špatně v tomto záznamu ?
International Physical Activity Questionnaire Short Form and accelerometer-assessed physical activity: concurrent validity using six cut-points in HF patients
C. Blasco-Peris, V. Climent-Paya, T. Vetrovsky, MI. García-Álvarez, A. Manresa-Rocamora, VJ. Beltrán-Carrillo, JM. Sarabia
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
Grantová podpora
2020-0333
Institute for Health and Biomedical Research of Alicante
DTS21/00171
Instituto de Salud Carlos III (ISCIII), co-funded by European Union. (ERDF, "A way to make Europe)
NLK
Directory of Open Access Journals
od 2014
Free Medical Journals
od 2014
PubMed Central
od 2015
Europe PubMed Central
od 2015
ProQuest Central
od 2014-09-01
Open Access Digital Library
od 2014-01-01
Open Access Digital Library
od 2014-09-01
Health & Medicine (ProQuest)
od 2014-09-01
Wiley-Blackwell Open Access Titles
od 2014
ROAD: Directory of Open Access Scholarly Resources
od 2014
PubMed
37842962
DOI
10.1002/ehf2.14514
Knihovny.cz E-zdroje
- MeSH
- akcelerometrie MeSH
- cvičení * MeSH
- lidé MeSH
- průzkumy a dotazníky MeSH
- srdeční selhání * diagnóza MeSH
- zpráva o sobě MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Physical activity (PA) is an important target for improving clinical outcomes in heart failure (HF) patients. Nonetheless, assessing the daily PA profile in this population is a challenging task, traditionally performed using self-report questionnaires such as the International PA Questionnaire Short Form (IPAQ-SF). This study aimed to evaluate the concurrent validity of the IPAQ-SF and accelerometer-assessed PA using six published cut-points in patients with HF and reduced or mildly reduced ejection fraction. METHODS AND RESULTS: The concordance between the IPAQ-SF and a hip-worn accelerometer regarding daily time spent performing moderate to vigorous PA in bouts of at least 10 min was assessed in 53 participants for seven consecutive days using six different cut-points (Barnett, Dibben, Mark, Sanders, Troiano, and Vaha-Ypya). Spearman's correlation and Bland-Altman plots were used to evaluate concurrent validity between methods. Regressions were used to study the association between patient variables, wear protocol (waking hour or 24 h), and absolute bias. The kappa index was used to evaluate the concordance between IPAQ-SF and accelerometry for classifying patients as active or non-active. All analyses were re-run using non-bouted metrics to investigate the effect of bouted versus non-bouted analysis. The IPAQ-SF and accelerometry showed low to negligible correlation (ρ = 0.12 to 0.37), depending on the cut-point used. The regression analysis showed that the absolute bias was higher in participants following the waking-hour protocol at all cut-points except Dibben's (P ≤ 0.007). The concordance between the two methods to classify patients as active and non-active was low when using Mark (κ = 0.23) and Barnett (κ = 0.34) cut-points and poor for the remaining cut-points (κ = 0.03 to 0.18). The results of the sensitivity analysis showed negligible to low correlation using non-bouted metrics (ρ = 0.27 to 0.33). CONCLUSIONS: Moderate to vigorous PA measures using IPAQ-SF and accelerometers are not equivalent, and we do not encourage researchers to use IPAQ-SF alone when assessing PA in HF patients. Moreover, applying personalized collection and processing criteria is important when assessing PA in HF patients. We recommend following the 24 h protocol and selecting cut-points calibrated in patients with cardiovascular diseases. Finally, it is necessary to develop a new tailored questionnaire that considers walking intensity and is adjusted to the current World Health Organisation recommendations, which use non-bouted metrics.
Alicante Institute for Health and Biomedical Research Alicante Spain
Department of Cardiology Dr Balmis General University Hospital Alicante Spain
Department of Physical Education and Sport University of Valencia Valencia Spain
Department of Sport Sciences Sports Research Centre Miguel Hernández University of Elche Elche Spain
Faculty of Physical Education and Sport Charles University Prague Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24007434
- 003
- CZ-PrNML
- 005
- 20240423155944.0
- 007
- ta
- 008
- 240412s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/ehf2.14514 $2 doi
- 035 __
- $a (PubMed)37842962
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Blasco-Peris, Carles $u Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain $u Department of Physical Education and Sport, University of Valencia, Valencia, Spain $1 https://orcid.org/0000000282571231
- 245 10
- $a International Physical Activity Questionnaire Short Form and accelerometer-assessed physical activity: concurrent validity using six cut-points in HF patients / $c C. Blasco-Peris, V. Climent-Paya, T. Vetrovsky, MI. García-Álvarez, A. Manresa-Rocamora, VJ. Beltrán-Carrillo, JM. Sarabia
- 520 9_
- $a AIMS: Physical activity (PA) is an important target for improving clinical outcomes in heart failure (HF) patients. Nonetheless, assessing the daily PA profile in this population is a challenging task, traditionally performed using self-report questionnaires such as the International PA Questionnaire Short Form (IPAQ-SF). This study aimed to evaluate the concurrent validity of the IPAQ-SF and accelerometer-assessed PA using six published cut-points in patients with HF and reduced or mildly reduced ejection fraction. METHODS AND RESULTS: The concordance between the IPAQ-SF and a hip-worn accelerometer regarding daily time spent performing moderate to vigorous PA in bouts of at least 10 min was assessed in 53 participants for seven consecutive days using six different cut-points (Barnett, Dibben, Mark, Sanders, Troiano, and Vaha-Ypya). Spearman's correlation and Bland-Altman plots were used to evaluate concurrent validity between methods. Regressions were used to study the association between patient variables, wear protocol (waking hour or 24 h), and absolute bias. The kappa index was used to evaluate the concordance between IPAQ-SF and accelerometry for classifying patients as active or non-active. All analyses were re-run using non-bouted metrics to investigate the effect of bouted versus non-bouted analysis. The IPAQ-SF and accelerometry showed low to negligible correlation (ρ = 0.12 to 0.37), depending on the cut-point used. The regression analysis showed that the absolute bias was higher in participants following the waking-hour protocol at all cut-points except Dibben's (P ≤ 0.007). The concordance between the two methods to classify patients as active and non-active was low when using Mark (κ = 0.23) and Barnett (κ = 0.34) cut-points and poor for the remaining cut-points (κ = 0.03 to 0.18). The results of the sensitivity analysis showed negligible to low correlation using non-bouted metrics (ρ = 0.27 to 0.33). CONCLUSIONS: Moderate to vigorous PA measures using IPAQ-SF and accelerometers are not equivalent, and we do not encourage researchers to use IPAQ-SF alone when assessing PA in HF patients. Moreover, applying personalized collection and processing criteria is important when assessing PA in HF patients. We recommend following the 24 h protocol and selecting cut-points calibrated in patients with cardiovascular diseases. Finally, it is necessary to develop a new tailored questionnaire that considers walking intensity and is adjusted to the current World Health Organisation recommendations, which use non-bouted metrics.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a cvičení $7 D015444
- 650 _2
- $a průzkumy a dotazníky $7 D011795
- 650 _2
- $a zpráva o sobě $7 D057566
- 650 _2
- $a akcelerometrie $7 D061725
- 650 12
- $a srdeční selhání $x diagnóza $7 D006333
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Climent-Paya, Vicente $u Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain $u Department of Cardiology, Dr Balmis General University Hospital (HGUA), Alicante, Spain $1 https://orcid.org/0000000173621922
- 700 1_
- $a Vetrovsky, Tomas $u Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000325297069 $7 xx0205902
- 700 1_
- $a García-Álvarez, María I $u Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain $u Department of Cardiology, Dr Balmis General University Hospital (HGUA), Alicante, Spain $1 https://orcid.org/0000000238631575
- 700 1_
- $a Manresa-Rocamora, Agustín $u Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain $u Department of Sport Sciences, Sports Research Centre, Miguel Hernández University of Elche, Elche, Spain $1 https://orcid.org/0000000213992411
- 700 1_
- $a Beltrán-Carrillo, Vicente J $u Department of Sport Sciences, Sports Research Centre, Miguel Hernández University of Elche, Elche, Spain $1 https://orcid.org/0000000187945901
- 700 1_
- $a Sarabia, José Manuel $u Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain $u Department of Sport Sciences, Sports Research Centre, Miguel Hernández University of Elche, Elche, Spain $1 https://orcid.org/0000000219176634
- 773 0_
- $w MED00197251 $t ESC heart failure $x 2055-5822 $g Roč. 11, č. 1 (2024), s. 126-135
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37842962 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240412 $b ABA008
- 991 __
- $a 20240423155941 $b ABA008
- 999 __
- $a ok $b bmc $g 2081425 $s 1217201
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 11 $c 1 $d 126-135 $e 20231016 $i 2055-5822 $m ESC heart failure $n ESC Heart Fail $x MED00197251
- GRA __
- $a 2020-0333 $p Institute for Health and Biomedical Research of Alicante
- GRA __
- $a DTS21/00171 $p Instituto de Salud Carlos III (ISCIII), co-funded by European Union. (ERDF, "A way to make Europe)
- LZP __
- $a Pubmed-20240412