• Je něco špatně v tomto záznamu ?

Steady state microdialysis of microliter volumes of body fluids for monitoring of amino acids by capillary electrophoresis with contactless conductivity detection

P. Tůma

. 2024 ; 1287 (-) : 342113. [pub] 20231206

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24007516

BACKGROUND: The availability of dialysis membranes in the form of hollow fibres with diameters compatible with the fused silica capillaries used in capillary electrophoresis is very limited. However, haemodialysis bicarbonate cartridges commonly used in human medicine containing polysulfone hollow fibres are available on the market and are used for the fabrication of coaxial microdialysis probes. The miniature probe design ensures that steady-state conditions are achieved during microdialysis of minimal volumes of body fluids. RESULTS: A coaxial microdialysis probe with a length of 5 cm and an inner diameter of 200 μm is used for microdialysis of 10 μL of body fluid collected into a sampling fused silica capillary with an inner diameter 430 μm. Microdialysis is performed into 0.01 M HCl as a perfusate at stopped flow and 2 μL of the resulting microdialysate are subjected to analysis by capillary electrophoresis with contactless conductivity detection. Microdialysis pre-treatment is verified by analysis of 11 common amino acids at a 100 μM concentration level, resulting in recoveries of 98.3-102.5%. The electrophoretic separation of amino acids is performed in 8.5 M acetic acid at pH 1.37 as a background electrolyte with analysis time up to 4.5 min and LOD in the range of 0.12-0.28 μM. The reproducibility of the developed technique determined for the peak area ranges from 1.2 to 4.5%. Applicability is tested in the quantification of valine and leucine in plasma during fasting and subsequent reconvalescence. SIGNIFICANCE: The fabrication of a coaxial microdialysis probe for the laboratory preparation of microliter volumes of various types of clinical samples is described, which is coupled off-line with capillary electrophoretic monitoring of amino acids in 2 μL volumes of microdialysate. The developed methodology is suitable for quantification of 20 amino acids in whole human blood, plasma, tears and has potential for analysis of dry blood spots captured on hollow fibre.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24007516
003      
CZ-PrNML
005      
20240423160028.0
007      
ta
008      
240412e20231206ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.aca.2023.342113 $2 doi
035    __
$a (PubMed)38182349
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Tůma, Petr $u Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague, 10, Czechia. Electronic address: petr.tuma@lf3.cuni.cz
245    10
$a Steady state microdialysis of microliter volumes of body fluids for monitoring of amino acids by capillary electrophoresis with contactless conductivity detection / $c P. Tůma
520    9_
$a BACKGROUND: The availability of dialysis membranes in the form of hollow fibres with diameters compatible with the fused silica capillaries used in capillary electrophoresis is very limited. However, haemodialysis bicarbonate cartridges commonly used in human medicine containing polysulfone hollow fibres are available on the market and are used for the fabrication of coaxial microdialysis probes. The miniature probe design ensures that steady-state conditions are achieved during microdialysis of minimal volumes of body fluids. RESULTS: A coaxial microdialysis probe with a length of 5 cm and an inner diameter of 200 μm is used for microdialysis of 10 μL of body fluid collected into a sampling fused silica capillary with an inner diameter 430 μm. Microdialysis is performed into 0.01 M HCl as a perfusate at stopped flow and 2 μL of the resulting microdialysate are subjected to analysis by capillary electrophoresis with contactless conductivity detection. Microdialysis pre-treatment is verified by analysis of 11 common amino acids at a 100 μM concentration level, resulting in recoveries of 98.3-102.5%. The electrophoretic separation of amino acids is performed in 8.5 M acetic acid at pH 1.37 as a background electrolyte with analysis time up to 4.5 min and LOD in the range of 0.12-0.28 μM. The reproducibility of the developed technique determined for the peak area ranges from 1.2 to 4.5%. Applicability is tested in the quantification of valine and leucine in plasma during fasting and subsequent reconvalescence. SIGNIFICANCE: The fabrication of a coaxial microdialysis probe for the laboratory preparation of microliter volumes of various types of clinical samples is described, which is coupled off-line with capillary electrophoretic monitoring of amino acids in 2 μL volumes of microdialysate. The developed methodology is suitable for quantification of 20 amino acids in whole human blood, plasma, tears and has potential for analysis of dry blood spots captured on hollow fibre.
650    _2
$a lidé $7 D006801
650    12
$a aminokyseliny $7 D000596
650    _2
$a mikrodialýza $7 D017551
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    12
$a tělesné tekutiny $7 D001826
650    _2
$a elektroforéza kapilární $7 D019075
650    _2
$a oxid křemičitý $7 D012822
655    _2
$a časopisecké články $7 D016428
773    0_
$w MED00000332 $t Analytica chimica acta $x 1873-4324 $g Roč. 1287 (20231206), s. 342113
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38182349 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240412 $b ABA008
991    __
$a 20240423160024 $b ABA008
999    __
$a ok $b bmc $g 2081488 $s 1217283
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 1287 $c - $d 342113 $e 20231206 $i 1873-4324 $m Analytica chimica acta $n Anal. chim. acta (Print) $x MED00000332
LZP    __
$a Pubmed-20240412

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...